Loading...

    Explore
    • Policy Monitoring
    • Live Policy Feed
    • Billing Codes
    • NPI Medicare & Medicaid
    • Healthcare Providers
    • Health Insurance Payers
    • States
    • Service Lines
    • Taxonomy Codes
    Lookup tools
    • Billing Code Lookup
    • CPT Modifier Lookup
    • Provider Taxonomy Code Lookup
    • Healthcare Provider & Facility Lookup
    • Health Insurance Payer Lookup
    • Payer Contact Directory

    Policy & Benchmark Tools

    • Prior Authorization Lookup
    • Coverage Criteria Lookup
    • Timely Filing Lookup
    • Billing Code Reimbursement Rates
    • Payer Comparison Dashboard
    • Facility Comparison Dashboard
    • All tools

    Company

    • About OpenPayer
    • Data Sources
    • Trek Health
    OpenPayerby Trek Health
    LinkedInYouTube

    © 2026 Trek Health. All rights reserved.

    OpenPayer is built and maintained by Trek Health.

    v1.0.28
    OpenPayerPolicy UpdatesDurable Medical Equipment (DME)Ambetter Nevada DME Coverage & Prior Auth Update |…
    Ask Trek AI about this page

    OpenPayer is powered by Trek Health's payer performance platform. Trek continuously ingests, validates, and normalizes Transparency in Coverage data alongside payer policies and other commercial payer data to create a structured payer intelligence foundation. OpenPayer uses this foundation to deliver personalized search results, dynamically generated policy pages, and tailored policy monitoring based on each user's payers, specialties, billing codes, and areas of interest. The same intelligence powers broader payer performance workflows, including reimbursement benchmarking, contract evaluation, payer negotiations, and financial decision-making.

    ModifiedAmbetter NevadaPolicy CP.MP.107

    Durable Medical Equipment and Orthotics and Prosthetics Guidelines

    Customize your policy alerts

    Sign up for Ambetter Nevada Policy CP.MP.107 alerts

    Get alerted when Policy CP.MP.107 changes without checking for updates manually.

    Monitor payer policy activity

    Receive email alerts as soon as relevant payer policies are published or updated.

    Criteria and coverage guidance for durable medical equipment (DME), orthotics, and prosthetics for Ambetter Nevada members, including general requirements and equipment-specific medical necessity rules.

    Policy Summary
    PayerAmbetter Nevada
    PolicyDurable Medical Equipment and Orthotics and Prosthetics Guidelines
    Policy CodePolicy CP.MP.107
    Change TypeMultiple material updates (added JACO, coding revisions, standing frame restructure)
    Effective Date
    Last ReviewNov 24, 2024
    Next Review Date
    Key ActionSubmit prior authorization and device-specific clinical documentation (including home evaluation or repair estimates) per policy for initial, replacement and repair DME requests.
    SourceLink
    POLICY UPDATE CHANGES

    Added criteria and coding for Wheelchair-mounted Assistive Robotic Arm (JACO).

    Removed neuromuscular stimulator, functional neuromuscular stimulator, and peroneal nerve stimulator; transferred to CP.MP.48 Neuromuscular Electrical Stimulation (NMES).

    Reorganized and revised Standing Frame criteria including new initial and replacement request requirements and pediatric age thresholds.

    Added numerous code updates and new sections (e.g., Lumbar-Sacral Orthotics (LSO); MyoPro Orthosis; microprocessor-controlled KAFO L2006).

    Updated pneumatic and non-pneumatic compression device criteria and clarified devices not proven safe/effective for select anatomic areas and arterial insufficiency.

    One month's rental of a standard manual wheelchair is medically necessary when a member's owned wheelchair is being repaired.

    Expanded references and updated multiple CPT/HCPCS code mappings and replacements (e.g., K1032/K1033 replaced with E0678/E0679; E2300 updated to E2298).

    newJACO criteria added
    5 yrsWheelchair lifetime
    300 lbsHeavy duty walker weight
    >= $250Breast pump threshold
    multipleSections updated
    1 monthTemporary rental allowed

    Coverage Criteria

    General criteria

    Durable medical equipment, orthotics, and prosthetics are medically necessary when ALL of the following are met:

    General criteria: 1. Education regarding use of the device provided with demonstrated understanding; 2. A trial of the requested device with demonstrated ability to use it safely and effectively.

    If a medically necessary, lesser cost item exists and will suit the member/enrollee's medical needs, a higher cost item will be denied.

    Burn garments

    Medically necessary with associated physical and/or occupational therapy when ALL of the following are met:

    Burn garments criteria: A. Member is at risk of a post-burn contracture; B. The garment and physical and/or occupational therapies are being used with the intent of preventing the need for skin grafting or contractures from hypertrophic scarring; C. Garment is requested by the PCP and/or the treating specialist.

    HCPCS A6501–A6512

    Policy Summary
    PayerAmbetter Nevada
    PolicyDurable Medical Equipment and Orthotics and Prosthetics Guidelines
    Policy CodePolicy CP.MP.107
    Change TypeMultiple material updates (added JACO, coding revisions, standing frame restructure)
    Effective Date
    Last ReviewNov 24, 2024
    Next Review Date
    Key ActionSubmit prior authorization and device-specific clinical documentation (including home evaluation or repair estimates) per policy for initial, replacement and repair DME requests.
    SourceLink
    On This Page
    Coverage CriteriaCoding and HCPCS/CPT MappingProvider Actions and Authorization RequirementsMedical Necessity DetailsRental and Purchase RulesReplacement PoliciesDocumentation RequirementsNot Covered Items and Investigational UsesDefinitionsBackgroundRevision History

    Breast pumps

    Breast pumps are covered when listed conditions are met:

    Breast pump criteria: A. Breast/chest feeding member if it is a covered benefit in the State; B. [clinical documentation per state coverage]; C. Purchase if cost is less than $250; D. If cost is greater than $250, approve as rental up to the purchase price then convert to purchase; E. Limit one per member/enrollee.<$250 = purchase; >$250 = rental then convert to purchase

    See newborn care equipment section for inclusive language and state benefit applicability.

    Enclosed beds

    Enclosed beds are reviewed by a medical director and/or therapy advisor and considered medically necessary when ALL of the following are met:

    Enclosed bed criteria: A. A standard bed or hospital bed is unable to meet positioning needs due to disability; B. Less intensive alternatives (e.g., bed rails, mattress on floor, removal of hazards, bed alarms, monitors, environmental modification, medication, routines/behavioral interventions) were tried and ruled out with documentation; C. Medical diagnosis (e.g., cerebral palsy, developmental delay, genetic or neurologic disorder) supports need; D. Healthcare provider evaluation including specific functional status and home evaluation, and documentation of caregiver education on proper use; E. Name of and invoice for the bed or enclosure provided with request.

    Only basic beds considered when criteria met; aesthetic or non-DME upgrades not covered. Prior review by medical director/therapy advisor required.

    Positioning seat

    Positioning seats are medically necessary when ALL of the following are met:

    Positioning seat criteria: A. Commercial devices cannot meet the member's positioning needs due to height, weight, or disability; B. Existing positioning devices in the home have been reviewed to avoid duplication; C. Therapist evaluation supports need and ongoing treatment is planned.

    Requests require physician or therapy advisor review; HCPCS T5001 or E1399.

    Not medically necessary: ROMTech PortableConnect

    ROMTech PortableConnect: Not medically necessary due to insufficient evidence in peer-reviewed literature to support safety or effectiveness over available alternatives.

    HCPCS E1399 and A9900

    Cervical traction

    Cervical traction equipment is medically necessary when ALL of the following are met:

    Cervical traction criteria: A. Appropriate use of the selected home cervical traction device has been demonstrated and was tolerated; B. One of the following exists: 1) Diagnosis of temporomandibular joint (TMJ) dysfunction with prior treatment; 2) Distortion of lower jaw/neck anatomy (e.g., radical neck dissection) preventing chin halter use; 3) Treating physician documents medical necessity for greater than 20 pounds of cervical traction in the home setting.

    HCPCS E0849; requests for custom cervical collars require therapist review if prefabricated collars inadequate (L0170/L0190/L0200).

    Prosthetics — initial and replacement

    Upper and lower extremity prosthetics requests are reviewed when listed initial or replacement criteria are met:

    Prosthetic initial criteria: A. Functional needs cannot be met with activity modification or compensatory techniques; B. Requested prosthesis is anticipated to meet functional needs; C. Clinical examination demonstrates appropriate residual limb length, stable limb volume, ability to tolerate weight of prosthesis, appropriate environmental exposures, access to specialized services, stable skin/strength/ROM, and cognitive function necessary to master prosthetic use; D. Comprehensive prosthetic rehabilitation plan including pre-prosthetic training, method of control, functional task training, home exercise program, and follow-up care schedule.

    Requests reviewed by medical director/therapy advisor; HCPCS upper and lower extremity codes apply.

    Prosthetic replacement criteria: A. Replacement requested because current prosthesis no longer functions properly, or physiologic/surgical changes to residual limb prevent accommodation, or irreparable wear/damage or repair cost > 60% of replacement cost, or significant change in condition resulting in poor fit/function; B. Prosthesis has been properly cared for per manufacturer's recommendations; C. Medical documentation supports continued use, motivation, appropriate functional level, replacement with same or similar prosthesis, and updated practitioner order if required.

    HCPCS replacement codes listed in policy.

    Infusion pumps

    Infusion pumps are medically necessary when indications and conditions are met:

    Ambulatory infusion pump indications: Medically necessary when used for administration of deferoxamine for acute iron poisoning; for select chemotherapy (e.g., unresectable hepatocellular carcinoma or colorectal liver metastases); with opioid drugs for intractable cancer pain; or when prolonged infusion (≥ 8 hours) provides improved clinical efficacy or strictly controlled infusion rate is necessary.≥ 8 hours when specified

    HCPCS E0780, E0781.

    Implantable infusion pump criteria: A. One of the specified indications met (e.g., certain liver cancer chemotherapy, intrathecal antispasmodics after failed trials with positive intrathecal trial, intrathecal opioids for intractable pain, or other drugs FDA-approved for pump use); B. No contraindications to implantation (drug allergy, active infection, insufficient body size, presence of another implanted programmable device, or intended drug is heparin/insulin).

    HCPCS E0782, E0783, E0785, E0786; trial documentation and contraindication assessment required.

    Oximeter monitoring

    Oximeters are medically necessary when used for monitoring in specific situations and NOT medically necessary for listed non-indicated uses:

    Oximeter medically necessary uses: To monitor individuals on a home ventilator or with a tracheostomy; to determine appropriate home oxygen requirements; to wean an individual from home oxygen; to monitor an unstable respiratory condition.

    HCPCS E0445.

    Oximeter not medically necessary uses: Oximetry when used as a diagnostic procedure, monitoring of a stable respiratory condition, asthma management, or other conditions not listed as indicated is not medically necessary.

    Not medically necessary: Ultrasonic nebulizer

    Ultrasonic nebulizer: Not medically necessary because it provides no clinical advantage over the use of a small-volume nebulizer and compressor.

    HCPCS E0575

    Walkers

    Standard and heavy duty walkers are medically necessary when ALL of the following are met:

    Standard walker criteria: A. Mobility-related activities of daily living (MRADLs) in the home cannot be met due to mobility limitation; B. Walker can be safely used by the member/enrollee; C. Functional mobility deficit will be sufficiently resolved with the use of a walker.

    HCPCS E0130, E0135, E0141, E0143.

    Heavy duty walker criteria: Meets standard walker criteria plus either: member/enrollee weighs more than 300 pounds (HCPCS E0148/E0149) OR the member is unable to use a standard walker due to a severe neurologic disorder or restricted use of one hand (HCPCS E0147).>300 pounds

    Weight threshold and device-specific HCPCS apply.

    Manual wheelchair

    Manual wheelchairs (initial) are medically necessary when ALL of the following are met:

    Manual wheelchair initial criteria: A. Mobility limitation interferes with ability to participate in MRADLs and: 1) limitation cannot be met with a cane or walker; 2) manual wheelchair will significantly improve MRADLs; 3) home provides adequate access and maneuvering space; 4) willingness by member/enrollee or caregiver to use a manual wheelchair in the home; B. One of the following: 1) caregiver able to assist with wheelchair use; 2) member able to safely and efficiently self-propel the manual wheelchair.

    HCPCS E1050, E1060, E1070, etc.

    Standard walker (initial)

    Requests for standard walkers are considered medically necessary when meeting ALL of the following:

    Standard walker criteria: A. Mobility-related activities of daily living (MRADLs) in the home cannot be met due to mobility limitation; B. Walker can be safely used by the member/enrollee; C. Functional mobility deficit will be sufficiently resolved with the use of a walker.

    HCPCS E0130, E0135, E0141, E0143.

    Heavy duty walker

    Requests for heavy duty walkers are medically necessary when meeting the standard walker criteria AND the following conditions:

    Heavy duty walker criteria: Member/enrollee weighs more than 300 pounds OR is unable to use a standard walker due to a severe neurologic disorder or other condition causing restricted use of one hand (E0147).>300 pounds

    E0148/E0149 for >300 lbs; E0147 for severe neurologic/restricted hand use.

    Manual wheelchair — Initial request

    Initial request is medically necessary when meeting ALL of the following:

    Initial manual wheelchair: A. Mobility limitation interferes with ability to participate in MRADLs and: 1) limitation cannot be met with a cane or walker; 2) manual wheelchair will significantly improve MRADLs; 3) home provides adequate access and maneuvering space; 4) willingness by member/enrollee or caregiver to use a manual wheelchair in the home; AND B. One of the following: 1) caregiver able to assist with wheelchair use; 2) member able to safely and efficiently self-propel the manual wheelchair.

    HCPCS series E1050–E1100 and examples listed in policy.

    Manual wheelchair — Replacement

    Replacement is medically necessary when documentation supports ANY of the following groups:

    Replacement reasons: Group A: Replacement necessary due to loss, theft, or irreparable damage AND documentation supports continued medical necessity AND replacement is with same or similar equipment. Group B: ALL of the following: 1) Replacement due to useful lifetime (>= 5 years) OR change in status requiring different equipment with growth features maximized; 2) Mobility limitation still interferes with MRADLs (subcriteria a–d as in initial criteria); 3) One of: caregiver assist or member able to self-propel safely.>=5 years

    Useful lifetime threshold of 5 years applies; documentation required for replacement justification.

    Wheelchair and other DME repairs

    Repairs are medically necessary when ALL of the following are met:

    Repair criteria: A. Item is less than 5 years old (age/date of purchase provided); B. Cost of repairs is less than the cost of replacement; C. Information supports need for repairs due to normal wear and tear rather than abuse/misuse or overutilization.<5 years

    Physician or therapy advisor review required for repair requests using codes K0108, K0739, or E1399. One month's rental of a standard manual wheelchair is medically necessary while owned wheelchair is being repaired.

    Power wheelchair — power seat elevator

    Power seat elevator on is medically necessary as a component on a power wheelchair when ALL of the following are met:

    Power seat elevator criteria: A. A licensed/certified medical professional (PT/OT) involved with assessment, prescription, trials and training; B. Adequate cognitive function to safely use the seat elevating feature; C. A clear functional need for the feature is indicated; D. Provision of the feature will improve functional independence for an activity (e.g., facilitating reach for ADLs/IADLs or improving transfer biomechanics and safety).

    HCPCS E2298.

    Rollabout chair

    Rollabout chair criteria: Medically necessary when used in lieu of a wheelchair for individuals who would qualify for a wheelchair except for the ability to self-propel a manual wheelchair.

    HCPCS E1031.

    Selected device coverage groups

    Covered when ALL of the following are met (device-specific examples from this segment):

    Standing Frame (pediatric) initial request: Meets age-based criteria AND documentation supports height and weight requirements, is alert and responsive to stimuli, has no contraindications to a standing program, and caregiver trained/available/able to safely assist.See pediatric thresholds (developmental delay in ambulation and ≥18 months; documented neurologic/neuromuscular impairments and ≥1 year)

    Replacement requests must meet existing initial criteria unless exception; documentation of training and size limits required.

    Wheelchair-mounted Assistive Robotic Arm (JACO): Device added with specific criteria to determine medical necessity; requests to be reviewed against device-specific functional requirements and supporting evidence.N/A

    New device-specific coding and criteria added; evidence currently limited.

    Pneumatic/Non-pneumatic Compression Devices: Coverage limited. Devices not proven safe/effective for lymphedema of the abdomen, trunk, chest, genitals, or neck and for arterial insufficiency; non-pneumatic device criteria added and some pneumatic device codes retired or revised.Anatomic and vascular contraindication exclusions apply

    Evidence reviews and CMS NCDs referenced; HCPCS E0678/E0679 noted.

    Orthotics/Prosthetics Code-based coverage: New Lumbar-Sacral Orthotics (LSO) section and additional orthotic/prosthetic codes added. Coverage requires device-specific clinical criteria, fitting, and functional deficit documentation.Device-specific functional deficits and fitting requirements per policy

    Codes L0450, L2006 (microprocessor-controlled KAFO) and other L-codes updated/added.

    The policy lists several miscellaneous exclusions and clarifications under coverage criteria. Notably, a non-wearable external defibrillator with integrated ECG analysis (HCPCS E0617) is considered not medically necessary because it is primarily a safety device rather than a therapeutic DME. The policy also states that non-pneumatic compression devices (HCPCS E0678, E0679) lack sufficient clinical evidence of safety and effectiveness compared with standard pneumatic compression devices and are therefore not supported for coverage in many indications.

    The ROMTech PortableConnect system is explicitly identified as not medically necessary. The policy states there is insufficient peer‑reviewed evidence to support clinical benefit over currently available alternatives and lists the applicable codes: E1399 and A9900.

    Intrapulmonary percussive ventilation (IPV) devices (examples: Volara™, Percussionaire TRUE‑IPV®) are noted as not supported by current evidence and therefore are considered not medically necessary in this policy context. The policy associates these devices with HCPCS E1399 when billed as unlisted DME.

    The policy designates whirlpool tubs (HCPCS E1310) as not medically necessary for the wound care uses described and therefore not covered under this DME policy.

    The JACO wheelchair‑mounted assistive robotic arm is addressed in the policy with respect to evidence and comparative outcomes. The policy states there is insufficient clinical evidence to demonstrate that the JACO arm provides improved safety or health outcomes compared with alternative technologies; as a result, coverage is not supported without clear device‑specific evidence and criteria.

    The policy clarifies limits for compression devices: devices have not been shown to be safe or effective for treatment of lymphedema affecting the abdomen, trunk, chest, genitals, or neck, and use is contraindicated for arterial insufficiency. The revised guidance updates pneumatic and non‑pneumatic device criteria and excludes coverage for devices used in these anatomic areas or vascular conditions where safety/effectiveness is not demonstrated.

    The ultrasonic nebulizer (HCPCS E0575) is stated to be not medically necessary because it offers no clinical advantage over a standard small‑volume nebulizer and compressor (e.g., E0574).

    The ROMTech PortableConnect device is reiterated as lacking sufficient evidence for clinical benefit and is therefore not medically necessary when billed under E1399 or A9900.

    Whirlpool tubs (HCPCS E1310) appear again in the exclusions list and are explicitly considered not medically necessary for the wound care indications referenced in the policy.

    Intrapulmonary percussive ventilation is addressed multiple times: the policy states that current evidence does not support the effectiveness of IPV and therefore it is considered not medically necessary when submitted under unlisted DME codes such as E1399.

    Coding and HCPCS/CPT Mapping

    Burn garments HCPCSHCPCSCovered
    A6501Burn garments - HCPCS
    A6502Burn garments - HCPCS
    A6503Burn garments - HCPCS
    A6504Burn garments - HCPCS
    A6505Burn garments - HCPCS
    A6506Burn garments - HCPCS
    A6507Burn garments - HCPCS
    A6508Burn garments - HCPCS
    A6509Burn garments - HCPCS
    A6510Burn garments - HCPCS
    1–10 of 12
    1/2
    External defibrillatorHCPCSNot Covered
    E0617Non-wearable external defibrillator with integrated ECG analysis
    Non-pneumatic compression devicesHCPCSNot Covered
    E0678Non-pneumatic compression device
    E0679Non-pneumatic compression device
    Voice synthesizer glucometerHCPCSCovered
    E2100Blood glucose monitor with integrated voice synthesizer
    Ultraviolet panel lightsHCPCSCovered
    E0691Ultraviolet panel light
    E0692Ultraviolet panel light
    E0693Ultraviolet panel light
    E0694Ultraviolet panel light
    Enclosed bedsHCPCS
    E0316Enclosed bed HCPCS
    E1399Enclosed bed miscellaneous HCPCS
    E0328Enclosed bed when combined with E0316 or E1399
    E0329Enclosed bed when combined with E0316 or E1399
    Positioning seatHCPCS
    T5001Positioning seat HCPCS
    E1399Positioning seat miscellaneous HCPCS
    ROMTech PortableConnectHCPCSNot Covered
    E1399ROMTech PortableConnect device
    A9900ROMTech PortableConnect device
    Cervical tractionHCPCS
    E0849Cervical traction equipment
    Custom cervical collarsHCPCS
    L0170Cervical collar, custom molded
    L0190Cervical collar, custom molded
    L0200Cervical collar, custom molded
    Spinal orthoticsHCPCS
    L0700Spinal orthotics
    L0710Spinal orthotics
    L0999Spinal orthotics
    L1000Spinal orthotics
    L1001Spinal orthotics
    L1005Spinal orthotics
    Orthotic componentsHCPCS
    L2570Orthotic components
    L2580Orthotic components
    L2627Orthotic components
    Custom foot orthoticsHCPCS
    L3000Custom foot orthotics
    L3001Custom foot orthotics
    L3002Custom foot orthotics
    L3003Custom foot orthotics
    L3010Custom foot orthotics
    L3020Custom foot orthotics
    L3030Custom foot orthotics
    L3031Custom foot orthotics
    L3070Custom foot orthotics
    Upper extremity prostheticsHCPCS
    L6000Upper extremity prosthetics and additions
    L6010Upper extremity prosthetics and additions
    L6020Upper extremity prosthetics and additions
    L6026Upper extremity prosthetics and additions
    L6050Upper extremity prosthetics and additions
    L6055Upper extremity prosthetics and additions
    L6100Upper extremity prosthetics and additions
    Breast prostheticsHCPCS
    L8030Breast prosthetics
    L8035Breast prosthetics
    Ambulatory infusion pumpsHCPCS
    E0780Ambulatory infusion pump
    E0781Ambulatory infusion pump
    Implantable infusion pumpsHCPCS
    E0782Implantable infusion pump
    E0783Implantable infusion pump
    E0785Implantable infusion pump
    E0786Implantable infusion pump
    Parenteral pumpHCPCS
    K0455Parenteral pump for medication administration
    Vacuum erection deviceHCPCS
    L7900Vacuum erection device
    L7902Vacuum erection device
    Ultrasonic nebulizerHCPCSNot Covered
    E0575Ultrasonic nebulizer
    IPPBHCPCS
    E0500IPPB & supplies
    E0550IPPB & supplies
    OximeterHCPCS
    E0445Oximeter
    Other surgical supplies HCPCSHCPCS
    L8040Other surgical supplies
    L8041Other surgical supplies
    L8042Other surgical supplies
    L8043Other surgical supplies
    L8044Other surgical supplies
    L8045Other surgical supplies
    L8046Other surgical supplies
    L8047Other surgical supplies
    L8499Other surgical supplies
    L8600Other surgical supplies
    1–10 of 16
    1/2
    Standard walkersHCPCS
    E0130Walker, standard
    E0135Walker, standard
    E0141Walker, standard
    E0143Walker, standard
    Heavy duty walkersHCPCS
    E0148Walker, heavy duty
    E0149Walker, heavy duty
    E0147Heavy duty walker with multiple braking system/variable wheel resistance
    Manual wheelchair HCPCSHCPCS
    E1050Manual wheelchair HCPCS series
    E1060Manual wheelchair HCPCS series
    E1070Manual wheelchair HCPCS series
    E1083Manual wheelchair HCPCS series
    E1084Manual wheelchair HCPCS series
    E1085Manual wheelchair HCPCS series
    E1086Manual wheelchair HCPCS series
    E1087Manual wheelchair HCPCS series
    E1088Manual wheelchair HCPCS series
    E1089Manual wheelchair HCPCS series
    1–10 of 14
    1/2
    Other surgical supplies HCPCSHCPCS
    L8040
    L8041
    L8042
    L8043
    L8044
    L8045
    L8046
    L8047
    L8499
    L8600
    1–10 of 16
    1/2
    WalkersHCPCSCovered
    E0130Walker, standard
    E0135Walker, standard
    E0141Walker, standard
    E0143Walker, standard
    E0147Walker, multiple braking/variable wheel resistance
    E0148Walker, heavy duty
    E0149Walker, heavy duty
    Manual wheelchair HCPCS (examples listed)HCPCSCovered
    E1050
    E1060
    E1070
    E1083
    E1084
    E1085
    E1086
    E1087
    E1088
    E1089
    1–10 of 36
    1/4
    Power wheelchair / repairs / otherHCPCS
    E2298Power seat elevator on
    E1399Unlisted DME (used in document for various items/repairs)
    K0108Wheelchair repair code referenced
    K0739Wheelchair repair code referenced
    E1031Rollabout chair
    Wound care equipmentHCPCSNot Covered
    E1310Whirlpool tub
    Highlighted Added/Updated HCPCS CodesHCPCS
    L0450LSO code (listed in LSO additions)
    L2006Microprocessor-controlled knee-ankle-foot orthosis (KAFO)
    E0678Non-pneumatic compression device (replacement for K1032)
    E0679Non-pneumatic compression device (replacement for K1033)
    E2298Power seat elevator on power wheelchair (updated from E2300)
    MyoPro Orthosis CodesHCPCS
    L8701MyoPro Orthosis - code listed under MyoPro section
    L8702MyoPro Orthosis - code listed under MyoPro section
    Not Supported/Investigational CodesHCPCSNot Covered
    E1399Intrapulmonary percussive ventilation - noted as not supported by current evidence
    Manual wheelchair useful lifetime — 5 years or more
    Manual wheelchair useful lifetimeReasonable useful lifetime defined as five years or more for replacement consideration.
    Replacement due to loss/theft/irreparable damageReplacement permitted before five years when documentation supports continued medical necessity and replacement is with same or similar equipment.
    Repairs vs replacementRepairs are preferred when item is <5 years old and repair cost is less than replacement cost; otherwise replacement considered.
    Breast pump purchase threshold — purchase vs rental threshold rules
    Purchase thresholdBreast pumps priced less than $250 may be approved as a purchase.
    Rental then convertBreast pumps with cost > $250 approved as rental up to the purchase price and then converted to purchase.
    Limit per memberLimit one breast pump per member/enrollee.
    Heavy duty walker weight threshold — > 300 lbs
    Heavy duty walker weight thresholdMember/enrollee weight greater than 300 pounds is required for heavy duty walkers (HCPCS E0148, E0149).
    Standard walker criteria prerequisiteHeavy duty walker requests must meet standard walker criteria in addition to weight threshold.
    Alternative HCPCS (E0147)E0147 (multiple braking/variable wheel resistance) is considered when member cannot use a standard walker due to restricted use of one hand or severe neurologic disorder.
    Useful lifetime for wheelchair replacement — >= 5 years
    Useful lifetime threshold for replacement>= 5 years is considered the reasonable useful lifetime for manual wheelchair replacement.
    Replacement exceptionsReplacement prior to the useful lifetime is allowed for loss, theft, or irreparable damage with documentation of continued medical necessity and replacement with same/similar equipment.
    Change in statusReplacement after useful lifetime may also be approved for a change in member status requiring different equipment when growth features of current equipment have been maximized.
    Weight threshold for heavy duty walker — > 300 pounds
    Heavy duty walker weight threshold> 300 pounds (member/enrollee weight) required for HCPCS E0148/E0149 heavy duty walker coverage.
    Standard walker criteria requiredRequest must also meet standard walker criteria: MRADLs cannot be met, safe use, and functional mobility benefit expected.
    E0147 criteriaE0147 (multiple braking/variable wheel resistance) considered when member cannot use a standard walker due to severe neurologic disorder or restricted use of one hand.
    Pediatric standing frame age thresholds — developmental delay and age-specific thresholds
    Developmental delay thresholdPediatric standing frame initial requests: developmental delay in ambulation and ≥ 18 months of age.
    Neurological/neuromuscular impairmentFor documented neurological or neuromuscular impairments, initial requests eligible at ≥ 1 year of age.
    Documentation requirementsDocumentation must support height/weight requirements, alertness/responsiveness, absence of contraindications to a standing program, and caregiver trained/available to assist.

    Provider Actions and Authorization Requirements

    Prior Authorization

    Prior Authorization Required

    Prior authorization is required for durable medical equipment (DME), orthotics, and prosthetics for initial requests, replacements, and specified repairs. Providers must obtain prior authorization before delivery or billing for items when noted in equipment-specific criteria or policy tables.

    • Prior authorization applies to initial purchases, replacements, and certain repairs (see repair codes K0108, K0739, E1399).
    • Replacement requests must document continued medical necessity and justification for replacement versus repair.
    • One month's rental for a standard manual wheelchair is considered medically necessary if an owned wheelchair is being repaired.
    Denial Risk

    Less-Costly Alternative Denial Risk

    If a medically necessary, lower-cost alternative exists that will meet the member's clinical needs, requests for higher-cost items will be denied. Providers should document why less costly options are not appropriate when requesting higher-cost devices.

    • Denial may be issued when a clinically appropriate, lower-cost item is available.
    • Providers should include evidence of prior trials of lesser-cost devices where applicable.
    Documentation Required

    Repairs Review and Documentation

    Repairs using specified codes require clinician review and supporting documentation. Repair requests must demonstrate the item is eligible for repair and that repair is cost-effective compared to replacement.

    • Repairs billed with K0108, K0739, or E1399 require review by a physician or therapy advisor.
    • Repair approval criteria include: item < 5 years old (provide age/date of purchase), repair cost less than replacement cost, and evidence repairs are for normal wear and tear rather than abuse or misuse.
    • Information on prior repair history and current condition must be supplied.
    Documentation Required

    Required Documentation for Bed/Enclosure and Positioning Devices

    Specific documentation is required to support requests for beds/enclosures and positioning devices. Complete submissions ensure timely review and reduce denial risk.

    • Therapist or physician evaluation detailing functional status, home evaluation, and education provided to caregivers.
    • Invoice or itemized quote for the bed or enclosure being requested.
    • For positioning devices: therapist evaluation, demonstration that commercial devices are inadequate due to height/weight/disability, and review of existing positioning devices to avoid duplication.
    Documentation Required

    Replacement and Repair Documentation Requirements

    Replacement and repair requests must include documentation that supports continued medical necessity, details the nature of damage, repair cost estimates, and evidence of proper care of the original device.

    • For prosthetic replacements: assessment of damage, repair cost estimate when applicable, evidence prosthesis was properly cared for per manufacturer guidelines, and documentation of continued functional benefit and motivation to use the device.
    • For wheelchair replacements: documentation of loss/theft or irreparable damage, or proof of end of reasonable useful lifetime (typically ≥5 years) and continued mobility need.
    • When requesting replacement due to change in condition, provide clinical evidence of change and rationale for different equipment.
    Documentation Required

    General Required Documentation

    All DME/O&P requests must include the required supporting clinical documentation outlined in the policy. Providers are responsible for supplying device-specific information to validate approvals.

    • Clinical evaluations (physician and/or therapist) describing diagnosis, functional limitations, and how the device addresses MRADLs.
    • Home environment assessment and confirmation of adequate access/space when applicable (e.g., wheelchairs).
    • Orders or prescriptions and item invoices/quotes. For specialized equipment, include age, weight, cognitive and caregiver capability information as requested by device-specific criteria.
    Step Therapy

    Mobility Escalation Requirement

    Mobility device escalation must be demonstrated: manual wheelchairs and lesser devices must be evaluated and shown insufficient before power or more complex mobility devices are approved.

    • Initial manual wheelchair requests require demonstration that mobility needs cannot be met with a cane or walker and that the wheelchair will significantly improve MRADLs.
    • Caregiver ability to assist or member ability to self-propel must be documented.
    • Power wheelchair criteria require therapist involvement in assessment, prescription, trials, and training; and documentation of the functional need for advanced features (e.g., seat elevator).
    Note

    Step/Criterion Deferral for Retired Specialized Equipment

    Certain retired or specialized equipment (for example, gait trainers and standing frames) have been deferred to standard IQ criteria or retired. Requests for these items should follow the current IQ/standard criteria or will be reviewed under general DME rules.

    • Gait trainers and standing frame criteria have been retired and are deferred to standard IQ criteria.
    • Providers should verify current policy sections or IQ guidance for equipment-specific requirements before submitting requests.

    Medical Necessity Details

    General DME criteria

    General DME medical necessity

    General DME: Education regarding device use with demonstrated understanding AND a trial of the requested device with demonstrated ability to use it safely and effectively.

    Applies to all DME, orthotics, and prosthetics; prior review may be required for higher-cost or not otherwise specified items.

    Manual wheelchair replacement

    Manual wheelchair replacement — rules including replacement interval and conditions:

    Manual wheelchair replacement: Replacement allowed when: 1) due to loss, theft, or irreparable damage with documentation and replacement with same/similar equipment; OR 2) replacement after reasonable useful lifetime of five years or more, or change in status requiring different equipment with growth features maximized and continued MRADL interference.>= 5 years

    Documentation required to support continued medical necessity and replacement justification.

    Mobility equipment medical necessity

    Walkers: Standard walker: MRADLs in the home cannot be met due to mobility limitation; walker can be safely used; functional mobility deficit will be sufficiently resolved with walker. Heavy duty walker: meets standard walker criteria plus member weight >300 lbs or inability to use standard walker due to severe neurologic disorder/restricted use of one hand.>300 pounds

    HCPCS E0130–E0149

    Manual wheelchair initial: Mobility limitation interfering with MRADLs not manageable with cane or walker; manual wheelchair will significantly improve MRADLs; home access adequate; willingness to use; caregiver assistance or ability to self-propel present.

    HCPCS E1050 series and examples in policy.

    Manual wheelchair replacement: Replacement due to loss/theft/irreparable damage with documentation and like replacement OR replacement after useful lifetime >=5 years or change in status requiring different equipment with prior growth maximized and continued MRADL interference.>=5 years

    DME medical necessity examples

    Examples of device-level medical necessity nodes:

    Temporary manual wheelchair rental during repair: One month's rental of a standard manual wheelchair is medically necessary if a member/enrollee's owned wheelchair is being repaired.1 month

    Added as temporary coverage guidance for repairs.

    Microprocessor-controlled KAFO (L2006): Coverage requires clinical documentation of functional need and device-specific fitting criteria as described in the orthotics section.N/A

    Code L2006 added; review per orthotics criteria.

    Rental and Purchase Rules

    ItemRule
    Breast pump
    Less than $250 — approve as purchase; Greater than $250 — approve as rental up to purchase price then convert to purchase; Limit one per member/enrollee.
    ItemRule
    Standard manual wheelchair — rental during repair
    One month's rental for a standard manual wheelchair is considered medically necessary if a member/enrollee's owned wheelchair is being repaired.
    PolicyImplication
    Preference for lower-cost medically necessary item
    If a lower-cost medically necessary item exists that will meet the member/enrollee's needs, the lower-cost item will be approved and a higher-cost item may be denied.
    ItemRule
    Standard manual wheelchair — rental
    Temporary rental for one month is medically necessary while a member/enrollee's owned standard manual wheelchair is being repaired.

    Replacement Policies

    Manual wheelchair — every 5 years or more (useful lifetime threshold)
    Manual wheelchair replacement intervalManual wheelchair replacement considered every 5 years or more (useful lifetime).
    Documentation for replacementReplacement requests must include documentation supporting reason for replacement (e.g., age/date of purchase, irreparable damage, or change in status).
    Repair preference when <5 yearsIf wheelchair is less than 5 years old, repairs are preferred provided repair cost is less than replacement and repairs are for normal wear-and-tear.
    Manual wheelchair — every 5 years or more (useful lifetime threshold duplicate)
    Manual wheelchair useful lifetime (duplicate)Reasonable useful lifetime for replacement is defined as five years or more.
    Replacement conditionsReplacement before useful lifetime allowed for loss/theft/irreparable damage with documentation and replacement with same/similar equipment.
    Functional criteria for replacementFor replacement after useful lifetime, continued interference with MRADLs and other baseline manual wheelchair criteria must be met.
    Standing frames and other DME — replacement per device-specific criteria; replacement requests must satisfy initial criteria unless exception
    Device-specific replacement ruleStanding frames and other specified DME replacements are governed by device-specific policy criteria; replacement requests must meet initial request criteria unless an exception applies.
    Exception for physiologic changesReplacements due to physiologic changes may be handled differently per device-specific guidance; policy reorganizations clarified replacement expectations.
    Documentation requiredProvider must supply clinical documentation verifying device-specific criteria (age, diagnosis, functional need, caregiver capability) for replacement approvals.

    Documentation Requirements

    Documentation Required

    Enclosed bed requests — supply home evaluation, functional status, caregiver education, and invoice

    For enclosed bed requests include a home evaluation and documentation of functional status, evidence that caregivers received education on proper use, and the name and invoice for the bed or enclosure being requested.

    • Home evaluation and functional status documented by the evaluator.
    • Caregiver education documentation specific to bed enclosure safety and use.
    • Submit the bed/enclosure name and invoice with the request.
    Documentation Required

    Prosthetic replacement — damage assessment, repair‑cost estimate, and care documentation required

    Prosthetic replacement submissions must include a damage assessment, repair cost estimate showing repair >60% of replacement when applicable, and documentation that the prosthesis was properly cared for per manufacturer guidance.

    • Provide evidence of irreparable damage or repair cost comparison (>60% threshold).
    • Include documentation of adherence to manufacturer's care recommendations.
    Documentation Required

    Provide purchase date, continued‑need documentation, and repair vs replacement justification

    To support approvals for replacements and repairs include the age/date of purchase, documentation of continued medical necessity for replacements, and justification why repair rather than replacement is appropriate (cost comparison and evidence of normal wear).

    • Age/date of purchase to verify repair eligibility (<5 years) or replacement useful lifetime (≥5 years).
    • Medical documentation supporting ongoing need for replacement.
    • Repair vs replacement cost justification showing repair is less costly when applicable.
    Documentation Required

    Supply clinical documentation verifying device‑specific age/diagnosis/function/caregiver criteria

    Providers must supply clinical documentation verifying device‑specific eligibility criteria — including age or pediatric thresholds, diagnosis, functional need, and caregiver capability — for devices such as standing frames and other specialized equipment.

    • For pediatric standing frames show age/thresholds, height/weight compliance, alertness/no contraindications, and caregiver training/availability.
    • Document diagnosis and functional deficits tied to the requested device's criteria.

    Not Covered Items and Investigational Uses

    Summary background: This DME, orthotics, and prosthetics policy defines which items are covered with criteria and which are excluded. Key examples of items identified as not covered or not medically necessary include a non‑wearable external defibrillator (E0617), non‑pneumatic compression devices (E0678, E0679), the ROMTech PortableConnect (E1399, A9900), ultrasonic nebulizers (E0575), intrapulmonary percussive ventilation (E1399), the JACO wheelchair‑mounted robotic arm (E1399 as billed) pending sufficient evidence, and whirlpool tubs (E1310). The policy revisions also document updated device‑specific sections and note the evidence reviews and citations considered during revision.

    Not covered grouping (duplicate entries consolidated): the document lists the same set of excluded or not‑medically‑necessary items across sections for clarity. These include E0617 (non‑wearable external defibrillator), E0678/E0679 (non‑pneumatic compression devices), E1399/A9900 (ROMTech PortableConnect), E0575 (ultrasonic nebulizer), E1399 (IPPV/IPV devices), E1310 (whirlpool tub), and the JACO robotic arm when billed to unlisted codes without supportive evidence.

    The policy repeats the exclusions in multiple sections to ensure billing and clinical staff recognize these are established non‑covered items. Examples reiterated include E0617, E0678/E0679, E1399/A9900, E0575, E1310, and IPV devices under E1399.

    Duplicate exclusion groupings in the not‑covered list serve as cross‑references to the device‑specific sections. Clinicians should note the coding examples provided for each excluded device when submitting claims or prior authorization requests.

    Administrative note: several non‑covered items are repeatedly listed to align with code tables and device sections. Operationally, these items should be treated as ineligible for coverage absent new, robust evidence or specific contractual provisions.

    Whirlpool tubs (HCPCS E1310) are listed under the not‑covered/wound care section and are considered not medically necessary for the indications described in this policy.

    The policy identifies the JACO wheelchair‑mounted robotic arm as an item for which available clinical evidence is insufficient to support coverage for safety or improved outcomes versus other assistive technologies. When billed under unlisted codes (e.g., E1399), the device does not meet the policy's coverage criteria without stronger evidence.

    Intrapulmonary percussive ventilation (IPV) and certain pneumatic compression device uses are specifically excluded. The policy states IPV lacks supportive evidence and is therefore not medically necessary (commonly billed under E1399), and some pneumatic/non‑pneumatic compression device applications (including treatment of specified anatomic areas and arterial insufficiency) are not considered proven safe or effective.

    Definitions

    DME — definition of Durable Medical Equipment
    Durable Medical Equipment (DME)Equipment that can withstand repeated use, is primarily and customarily used to serve a medical purpose, appropriate for home use, and not generally useful in absence of illness or injury.
    Durable vs expendableDurable items are those that can be rented due to repeatable use; expendable supplies (e.g., incontinence pads, catheters) are not considered durable.
    Home use suitabilityDME is appropriate for use in the member/enrollee's home setting when prescribed by a physician and necessary for treatment of an illness or injury.
    Orthotic — definition of orthotic devices
    Orthotic definitionOrthotic devices are rigid and semi-rigid devices used to support a weak or deformed body part or to restrict or eliminate motion in a diseased or injured body part.
    ExamplesOrthotics include braces and other support devices; some durable items may fall into orthotics/prosthetics coverage categories.
    Durability noteAlthough some orthotics are durable, coverage category may vary and documentation may be required to determine appropriateness.
    Prosthetic — definition of prosthetic devices
    Prosthetic definitionProsthetic devices are custom-made artificial limbs or assistive devices that replace a body part or function due to trauma, vascular disease, diabetes, cancer, or congenital disorders.
    Coverage considerationsProsthetic requests are reviewed for functional need, residual limb characteristics, ability to tolerate weight, and comprehensive rehabilitation plan.
    Replacement documentationReplacement prosthetic requests require documentation of irreparable damage or repair cost >60% of replacement and evidence of proper care.
    Member/Enrollee's Home — definition of member's home
    Member/Enrollee's Home definitionA dwelling, apartment, relative's home, home for the aged, or other institution unless the institution meets hospital or skilled nursing facility definitions; permanent admission to SNF/hospice makes that facility the member's home.
    Impact on rental/purchasePlace-of-home status affects rental and purchase rules for DME and whether an institution is considered the member's home.
    Documentation implicationsDetermination may require facility classification based on services provided (e.g., inpatient skilled nursing care).
    Durable / Medical Equipment — distinction and definition details
    Durable vs Medical Equipment distinctionDurable items withstand repeated use and are typically rent-type items; medical equipment is primarily for medical purposes and not generally useful absent illness or injury.
    Coverage category noteSome durable items may fall into other coverage categories (e.g., supplies, orthotics, prosthetics) and require documentation to determine classification.
    Expendable supplies exclusionExpendable medical supplies (e.g., ace bandages, elastic stockings) are not considered durable equipment.
    JACO — Wheelchair-mounted Assistive Robotic Arm (definition)
    JACO definitionWheelchair-mounted Assistive Robotic Arm (JACO) — a robotic arm mounted to a wheelchair; policy notes insufficient clinical evidence for improved outcomes in some contexts and adds device-specific criteria.
    HCPCS codingDocument references JACO typically represented with unlisted code E1399 when used for this item.
    Policy actionJACO criteria and coding were added to the policy; requests will be reviewed against device-specific functional requirements.
    LSO — Lumbar-Sacral Orthotics (LSO) newly added orthotic category
    LSO definitionLumbar-Sacral Orthotics (LSO) — a newly added orthotic category in the policy with multiple HCPCS L-codes enumerated for coverage review.
    Included codesPolicy lists numerous LSO codes (e.g., L0450, L0452, L0454 ... L1005) to define the category and facilitate claims review.
    Clinical criteriaLSO coverage is governed by the orthotics section criteria and device-specific fitting and functional requirements.

    Background

    Background: Durable medical equipment (DME) includes reusable medical devices intended for home use; orthotics support or restrict body parts; prosthetics replace a body part or function. The policy requires education and a trial demonstrating safe and effective use prior to coverage decisions, and it provides device‑specific criteria and exclusions for common DME categories.

    Revision History

    2021-08-21criteria_revision

    Standing Frame criteria reorganized; initial and replacement requests revised with pediatric age thresholds and documentation requirements for height/weight, alertness, and contraindications to standing program.

    2021-07-21additionLatest

    Added device-specific criteria and coding for Wheelchair-mounted Assistive Robotic Arm (JACO) and removed neuromuscular stimulator items (transferred to CP.MP.48); revised pneumatic compression device guidance and other references updated.

    Documentation and prior authorization requirements apply.