Loading...

    Explore
    • Policy Monitoring
    • Live Policy Feed
    • Billing Codes
    • Healthcare Providers
    • Health Insurance Payers
    • States
    • Service Lines
    • Taxonomy Codes
    Lookup tools
    • Billing Code Lookup
    • CPT Modifier Lookup
    • Provider Taxonomy Code Lookup
    • Healthcare Provider & Facility Lookup
    • Health Insurance Payer Lookup
    • Payer Contact Directory

    Policy & Benchmark Tools

    • Prior Authorization Lookup
    • Coverage Criteria Lookup
    • Timely Filing Lookup
    • Billing Code Reimbursement Rates
    • Payer Comparison Dashboard
    • Facility Comparison Dashboard
    • All tools

    Company

    • About OpenPayer
    • Data Sources
    • Request a Policy / Feedback
    • Trek Health
    OpenPayerby Trek Health
    LinkedInYouTube

    © 2026 Trek Health. All rights reserved.

    OpenPayer is built and maintained by Trek Health.

    v1.0.32
    OpenPayerPolicy UpdatesOtorhinolaryngology (ENT)Mass General Brigham Hearing Coverage | OpenPayer
    Ask Trek AI about this page
    ModifiedMass General Brigham Health PlanPolicy 025

    Medical Necessity Guidelines Hearing Devices

    Customize your policy alerts

    Sign up for Mass General Brigham Health Plan Policy 025 alerts

    Get alerted when Policy 025 changes without checking for updates manually.

    Monitor payer policy activity

    Receive email alerts as soon as relevant payer policies are published or updated.

    Requirements for determining medical necessity and coverage of assistive hearing devices, including hearing aids, cochlear implants, bone-anchored devices, and auditory brainstem implants, across Medicare Advantage, Mass General Brigham ACO, One Care/SCO, Commercial, and Qualified Health Plan products.

    Policy Summary
    PayerMass General Brigham Health Plan
    PolicyMedical Necessity Guidelines Hearing Devices
    Policy CodePolicy 025
    Change TypeModified
    Effective DateOctober 1, 2026
    Last ReviewOct 1, 2026
    Next Review DateNot specified
    Key ActionObtain prior authorization for covered hearing devices requiring it under the member’s plan.
    SourceLink
    POLICY UPDATE CHANGES

    The October 1, 2026 ad hoc review updated the ACO section.

    The August 1, 2026 ad hoc review updated the description of customization to the pediatric cochlear implant InterQual subset.

    The July 1, 2026 annual review removed the reference to the custom air conduction hearing aids subset because the subset was retired.

    The March 2026 ad hoc review removed references to retired custom BAHD/BAHA and auditory brainstem implant InterQual subsets.

    The March 2026 ad hoc review clarified the criteria hierarchy in the One Care and SCO section.

    The July 2025 annual review removed cochlear implants from the prior authorization table and clarified the Medicare variation.

    OpenPayer is powered by Trek Health's payer performance platform. Trek continuously ingests, validates, and normalizes Transparency in Coverage data alongside payer policies and other commercial payer data to create a structured payer intelligence foundation. OpenPayer uses this foundation to deliver personalized search results, dynamically generated policy pages, and tailored policy monitoring based on each user's payers, specialties, billing codes, and areas of interest. The same intelligence powers broader payer performance workflows, including reimbursement benchmarking, contract evaluation, payer negotiations, and financial decision-making.

    4Plan sections requiring prior authorization
    18+ vs under 18Cochlear implant criteria pathways
    5 yearsMinimum age for covered BAHD/BAHA
    12 yearsMinimum age for covered auditory brainstem implant
    ExcludedSemi- and fully implantable middle-ear hearing aids

    Medical Necessity and Coverage Criteria

    Air Conduction and Non-Implantable Bone Conduction Hearing Aids

    Medical necessity is determined through InterQual® criteria. Access the Mass General Brigham Health Plan Hearing Aids Custom criteria by logging into the provider website at MassGeneralBrighamHealthPlan.org and selecting the InterQual® Criteria Lookup link under the Resources menu.

    ALL of the following

    • The requested device is an air conduction hearing aid or a non-implantable bone conduction hearing aid.
    • The member meets the applicable Mass General Brigham Health Plan InterQual® medical-necessity criteria.

    Cochlear Implants

    Cochlear implantation is medically necessary when the member meets the applicable InterQual® pathway. Access the criteria by logging into the Mass General Brigham Health Plan provider website at MassGeneralBrighamHealthPlan.org and selecting the InterQual® Criteria Lookup link under the Resources menu.

    ONE of the following pathways

    • Adult pathway

      • The member is 18 years of age or older.
      • The member meets the applicable InterQual® criteria for cochlear implantation.
    • Pediatric pathway

      • The member is under 18 years of age.
      • The member meets the Mass General Brigham Health Plan-customized InterQual® criteria for cochlear implantation, including the updated MRI requirements.

    BAHD/BAHA for Conductive or Mixed Hearing Loss

    BAHD/BAHA is covered for members who are at least 5 years old and meet all applicable criteria below.

    ALL of the following

    • The member is at least 5 years old.
    • Conductive or mixed hearing loss pathway

      • The member has conductive or mixed hearing loss and is unable to use conventional air conduction hearing aids.
      • ONE of the following conditions

        • Congenital, surgical, or acquired malformations of the external ear canal or middle ear canal.
        • Tumors of the external canal and/or tympanic cavity.

    BAHD/BAHA for Single-Sided Deafness

    BAHD/BAHA is covered for members who are at least 5 years old and meet all criteria below.

    ALL of the following

    • The member is at least 5 years old.
    • The member has single-sided deafness.
    • The member has normal bone conduction in the good ear (at least a 25 dB threshold) or only mildly reduced bone conduction in the good ear (26–40 dB), measured at 500 Hz, 1000 Hz, 2000 Hz, and 3000 Hz.
    • A conventional CROS or (bi)CROS aid, whichever is most appropriate, has been considered and is not a viable option.
    • A nonpermanent BAHD test band/soft band has been tried and improved the member's word recognition and speech comprehension, particularly in noisy environments.

    Auditory Brainstem Implant

    Mass General Brigham Health Plan covers unilateral auditory brainstem implants using surface electrodes on the cochlear nuclei when all criteria are met.

    ALL of the following

    • The member has neurofibromatosis type II.
    • The member is 12 years of age or older.
    • The member has been rendered deaf due to bilateral resection of the cochlear nerve.

    Mass General Brigham Health Plan does not cover hearing or listening devices, or device features, that are principally used for convenience and are not medically necessary. Devices or device features considered experimental and investigational are also not covered, including semi-implantable and fully implantable middle ear hearing aids.

    BAHD/BAHA is not covered for any reason other than the indications listed in these coverage criteria, including conditions or diagnoses not covered under these criteria. Pure bilateral sensorineural hearing loss is excluded.

    Auditory brainstem implants are not covered for any reason other than the unilateral implant indication listed above, or for conditions or diagnoses not covered under these coverage criteria.

    Prior authorization is required for air conduction hearing aids, non-implantable bone conduction hearing aids, bone-anchored hearing devices/aids, and auditory brainstem implants. Prior authorization is not required for cochlear implants. The specialist and/or primary care provider must provide all necessary clinical information, including the presenting condition, history of hearing loss, and medical-necessity rationale, for benefit determination.

    Non-medically necessary accessories are excluded, including Bluetooth accessories, accessories for recreational use, accessories for water use, and duplicate accessories. Convenience-use devices or features and experimental or investigational devices or features are not covered.

    Replacement or repair of a BAHD/BAHA processor is not covered when the processor remains under the manufacturer's warranty; when it is lost, stolen, or damaged due to improper care, misuse, or neglect; or when the member has a functioning model and a newer or upgraded model is not medically necessary. Mass General Brigham Health Plan may require proof of a stolen or damaged item, such as a police report, pictures, or a corroborating statement.

    Coding and Clinical Thresholds

    Informational hearing device codesHCPCS
    V5014Repair/modification of a hearing aid
    V5030Hear Aid Monaural Bdy Wrn Air Condct
    V5040Hear Aid Monaural Bdy Worn BN Condct
    V5060Hearing Aid Monaural in the Ear
    V5070Hearing Aid Monaural in the Ear
    V5080Glasses Bone Conduction
    V5100Hearing Aid Bilateral Body Worn
    V5120Hearing Aid Monaural in the Ear
    V5130Binaural in the Ear
    V5140Binaural Behind the Ear
    1–10 of 47
    1/5
    Hearing aid and ear mold codesHCPCS
    V5230Hearing Aid Monaural in the Ear = Hearing Aid BICROS Glasses
    V5242Hearing Aid Monaural in the Ear = Hearing Aid Analog Monaural CIC
    V5243Hearing Aid Monaural in the Ear = Hearing Aid Analog Monaural ITC
    V5244Hearing Aid Monaural in the Ear = Hearing Aid Prog Analog Monaural CIC
    V5245Hearing Aid Monaural in the Ear = Hearing Aid Prog Analog Monaural ITC
    V5246Hearing Aid Monaural in the Ear = Hearing Aid Prog Analog Monaural ITE
    V5247Hearing Aid Monaural in the Ear = Hearing Aid Prog Analog Monaural BTE
    V5248Hearing Aid Monaural in the Ear = Hearing Aid Analog Binaural CIC
    V5249Hearing Aid Monaural in the Ear = Hearing Aid Analog Binaural ITC
    V5250Hearing Aid Prog Analog Binaural CIC
    1–10 of 25
    1/3
    Cochlear implant and auditory osseointegrated device codesHCPCS
    L8614Ear mold/insert, disposable, any type
    L8619Cochlear implant, external speech processor and controller, integrated system, replacement
    L8621Zinc air battery for use with cochlear implant device and auditory osseointegrated sound processors, replacement, each
    L8622Sound processors, replacement, each
    L8627Cochlear implant, external speech processor, component, replacement
    L8628Cochlear implant, external controller component, replacement
    L8690Auditory osseointegrated device, includes all internal and external components
    L8691Auditory osseointegrated device, external sound processor, excludes transducer/actuator, replacement only, each
    L8693Auditory osseointegrated device abutment, any length, replacement only
    L8694Auditory osseointegrated device, transducer/actuator, replacement only, each
    Implantation and replacement procedure codesCPT
    69714Implantation, osseointegrated implant, skull; with percutaneous attachment to external speech processor
    69730Replacement, including removal of existing device, osseointegrated implant, skull; with magnetic transcutaneous attachment to external speech processor, outside the mastoid and involving a bony defect greater than or equal to 100 sq mm surface area of bone deep to the outer cranial cortex
    69930Cochlear device implantation, with or without mastoidectomy
    S2235Implantation of auditory brain stem implant
    BAHD/BAHA Age
    Minimum ageAt least 5 years old
    Applies toMembers receiving covered BAHD/BAHA for conductive or mixed hearing loss or single-sided deafness
    Coverage conditionAll applicable BAHD/BAHA criteria must be met
    BAHD/BAHA Bilateral Bone-Conduction Symmetry
    Average inter-ear differenceLess than 10 dB average difference between left- and right-side bone-conduction thresholds
    Test frequencies500 Hz, 1000 Hz, 2000 Hz, and 3000 Hz

    Prior Authorization and Documentation

    Prior Authorization

    Obtain prior authorization for applicable Medicare Advantage devices

    For Medicare Advantage members, prior authorization is required for air conduction hearing aids, non-implantable bone conduction hearing aids, bone-anchored hearing devices or aids, and auditory brainstem implants. Prior authorization is not required for cochlear implants.

    • Air conduction hearing aids
    • Non-implantable bone conduction hearing aids
    • Bone-anchored hearing devices/aids
    • Auditory brainstem implants
    Prior Authorization

    Obtain prior authorization for applicable ACO devices

    For Mass General Brigham ACO members, prior authorization is required for air conduction hearing aids, non-implantable bone conduction hearing aids, bone-anchored hearing devices or aids, and auditory brainstem implants. Prior authorization is not required for cochlear implants.

    • Air conduction hearing aids

    Policy Background

    This policy addresses assistive hearing devices used to aid or compensate for hearing loss. The scope includes air-conduction and non-implantable bone-conduction hearing aids, bone-anchored hearing devices such as BAHD/BAHA, cochlear implants, and auditory brainstem implants. Coverage is determined according to medical necessity and the applicable clinical criteria for the device category; semi-implantable and fully implantable middle-ear hearing aids are identified as experimental and investigational.

    Device Definitions

    Air Conduction Hearing Aid
    Device typeA wearable aid or device that does not include surgical implants
    PlacementInserted directly into the ear or worn with an ear mold and an air-conduction receiver or bone-oscillator attachment
    PurposeDesigned to aid or compensate for hearing loss; includes parts, attachments, and accessories but excludes batteries, cords, and accessories thereto
    Non-implantable Bone Conduction Hearing Aid
    Device typeA non-surgically implanted, wearable aid or device
    PositioningThe bone vibrator is tightly held against the mastoid process by a headband
    Policy Summary
    PayerMass General Brigham Health Plan
    PolicyMedical Necessity Guidelines Hearing Devices
    Policy CodePolicy 025
    Change TypeModified
    Effective DateOctober 1, 2026
    Last ReviewOct 1, 2026
    Next Review DateNot specified
    Key ActionObtain prior authorization for covered hearing devices requiring it under the member’s plan.
    SourceLink
    On This Page
    Medical Necessity and Coverage CriteriaCoding and Clinical ThresholdsPrior Authorization and DocumentationPolicy BackgroundDevice Definitions
    Severe, chronic otitis externa or otitis media; hypersensitivity to ear molds used in air conduction hearing aids; or recalcitrant dermatitis of the external ear.
  1. ONE of the following audiologic findings

    • The requested processor is appropriate to meet the member's needs based on the pure tone average bone-conduction threshold measured at 500 Hz, 1000 Hz, 2000 Hz, and 3000 Hz.
    • Bilateral implantation

      • The patient meets the applicable audiologic criteria.
      • The patient has a symmetrically conductive or mixed hearing loss, defined as a difference of less than 10 dB on average between left- and right-side bone-conduction thresholds measured at 500 Hz, 1000 Hz, 2000 Hz, and 3000 Hz, or less than 15 dB at individual frequencies.
  2. A nonpermanent BAHD test band/soft band has been tried and improved the member's word recognition and speech comprehension, particularly in noisy environments.
  3. The member has been counseled regarding reasonable expectations of BAHD performance.
  4. The member is motivated to use the device.
  5. The member has been counseled regarding reasonable expectations of BAHD performance.
  6. The member is motivated to use the device.
  7. Individual-frequency differenceLess than 15 dB at individual frequencies
    Single-Sided Deafness: Good-Ear Bone Conduction
    Normal hearing thresholdAt least a 25 dB bone-conduction threshold in the good ear
    Mildly reduced threshold26–40 dB bone-conduction threshold in the good ear
    Test frequencies500 Hz, 1000 Hz, 2000 Hz, and 3000 Hz
    Auditory Brainstem Implant Age
    Minimum age12 years of age or older
    Covered implantUnilateral auditory brainstem implant using surface electrodes on the cochlear nuclei
    Additional eligibilityThe member must have neurofibromatosis type II and deafness due to bilateral resection of the cochlear nerve
  8. Non-implantable bone conduction hearing aids
  9. Bone-anchored hearing devices/aids
  10. Auditory brainstem implants
  11. Prior Authorization

    Obtain prior authorization for applicable One Care and SCO devices

    For One Care and Senior Care Options members, prior authorization is required for air conduction hearing aids, non-implantable bone conduction hearing aids, bone-anchored hearing devices or aids, and auditory brainstem implants. Prior authorization is not required for cochlear implants.

    • Air conduction hearing aids
    • Non-implantable bone conduction hearing aids
    • Bone-anchored hearing devices/aids
    • Auditory brainstem implants
    Prior Authorization

    Obtain prior authorization for applicable Commercial and QHP devices

    For Commercial and Qualified Health Plan members, prior authorization is required for air conduction hearing aids, non-implantable bone conduction hearing aids, bone-anchored hearing devices or aids, and auditory brainstem implants. Prior authorization is not required for cochlear implants.

    • Air conduction hearing aids
    • Non-implantable bone conduction hearing aids
    • Bone-anchored hearing devices/aids
    • Auditory brainstem implants
    Documentation Required

    Submit clinical information and medical necessity rationale

    The specialist and/or primary care provider must provide all necessary clinical information for the determination of benefit coverage, including the presenting condition(s), history of hearing loss, and medical necessity rationale.

    • Presenting condition(s)
    • History of hearing loss
    • Medical necessity rationale
    Documentation Required

    Document BAHD/BAHA supporting criteria

    For BAHD/BAHA requests, document the relevant hearing-loss type or single-sided deafness, required audiologic findings, and the member’s response to a nonpermanent test band or soft band. Also document counseling regarding reasonable performance expectations and the member’s motivation to use the device.

    • Conductive or mixed hearing loss, or single-sided deafness
    • Pure-tone average bone-conduction findings at 500, 1000, 2000, and 3000 Hz
    • Trial of a nonpermanent BAHD test band or soft band
    • Improved word recognition and speech comprehension, particularly in noisy environments
    • Counseling regarding reasonable expectations
    • Member motivation to use the device
    Documentation Required

    Provide proof for a stolen or damaged processor

    For replacement of a stolen or damaged processor, Mass General Brigham Health Plan may require proof of the stolen or damaged item. Acceptable proof may include a police report, pictures, or a corroborating statement.

    • Police report
    • Pictures
    • Corroborating statement
    Denial Risk

    Avoid convenience and experimental device requests

    Hearing/listening devices or device features principally used for convenience rather than medical necessity, or devices or features considered experimental and investigational, are not covered. Examples include semi-implantable and fully implantable middle ear hearing aids.

    • Do not request devices principally used for convenience.
    • Do not request experimental or investigational devices or features.
    • Semi-implantable and fully implantable middle ear hearing aids are examples of excluded devices.
    Denial Risk

    Confirm the BAHD/BAHA indication is eligible

    BAHD/BAHA is excluded for indications other than those listed in the coverage criteria, for conditions or diagnoses not covered under those criteria, and for pure bilateral sensorineural hearing loss.

    • Indications other than those listed in the coverage criteria
    • Conditions or diagnoses not covered under the criteria
    • Pure bilateral sensorineural hearing loss
    Denial Risk

    Check processor replacement and repair exclusions

    Replacement or repair of a BAHD/BAHA processor is excluded when the processor remains under manufacturer warranty, is lost or stolen, or is damaged due to improper care, misuse, or neglect. It is also excluded when the member has a functioning model and a newer or upgraded model is not medically necessary.

    • Still under manufacturer warranty
    • Lost or stolen
    • Damaged due to improper care, misuse, or neglect
    • Functioning model with no medical necessity for a newer or upgraded model
    Denial Risk

    Avoid excluded accessory requests

    Non-medically necessary accessories are excluded, including Bluetooth accessories, accessories for recreational use, accessories for water use, and duplicate accessories.

    • Bluetooth accessories
    • Accessories for recreational use
    • Accessories for water use
    • Duplicate accessories
    Denial Risk

    Confirm auditory brainstem implant eligibility

    Auditory brainstem implants are excluded for any reason other than the listed coverage criteria and for all conditions or diagnoses not covered under those criteria.

    • Request only for the listed coverage criteria
    • Confirm that the condition or diagnosis is covered under those criteria
    Sound routing
    Routes sound transcranially via bone conduction to the cochlea of the normal ear and may improve awareness and recognition of speech arriving on the side of the poorer ear
    Semi-Implantable and Fully Implantable Hearing Aid
    ComponentsAn audio processor, receiver, and implanted electromagnetic transducer
    Transducer placementThe transducer contacts the ossicles or is close to a magnet implanted on the ossicles
    ExamplesVibrant Soundbridge, Soundtec, Direct System, and Esteem implantable hearing system
    BAHD/BAHA
    Device typeBone-anchored devices with sound processors attached or implanted to skull bone
    Sound transmissionRelies on bone conduction
    Common terminologyBAHD means bone-anchored hearing device; BAHA means bone-anchored hearing aid
    Cochlear Implant
    Device typeAn electronic device designed to provide a sense of sound for individuals with severe to profound sensorineural hearing loss
    Signal conversionConverts sound into electrical signals
    MechanismDirectly stimulates the auditory nerve, bypassing damaged cochlear hair cells
    Auditory Brainstem Implant
    PurposeProvides sound perception when the cochlea or auditory nerve is damaged and cochlear implantation is not an option
    MechanismDirectly stimulates the brainstem and bypasses damaged parts of the auditory pathway
    Typical clinical contextIncludes patients with neurofibromatosis type II or congenital absence or severe damage to the cochlear nerve