Air Conduction and Non-Implantable Bone Conduction Hearing Aids
Medical necessity is determined through InterQual® criteria. Access the Mass General Brigham Health Plan Hearing Aids Custom criteria by logging into the provider website at MassGeneralBrighamHealthPlan.org and selecting the InterQual® Criteria Lookup link under the Resources menu.
ALL of the following
The requested device is an air conduction hearing aid or a non-implantable bone conduction hearing aid.
The member meets the applicable Mass General Brigham Health Plan InterQual® medical-necessity criteria.
Cochlear Implants
Cochlear implantation is medically necessary when the member meets the applicable InterQual® pathway. Access the criteria by logging into the Mass General Brigham Health Plan provider website at MassGeneralBrighamHealthPlan.org and selecting the InterQual® Criteria Lookup link under the Resources menu.
ONE of the following pathways
Adult pathway
The member is 18 years of age or older.
The member meets the applicable InterQual® criteria for cochlear implantation.
Pediatric pathway
The member is under 18 years of age.
The member meets the Mass General Brigham Health Plan-customized InterQual® criteria for cochlear implantation, including the updated MRI requirements.
BAHD/BAHA for Conductive or Mixed Hearing Loss
BAHD/BAHA is covered for members who are at least 5 years old and meet all applicable criteria below.
ALL of the following
The member is at least 5 years old.
Conductive or mixed hearing loss pathway
The member has conductive or mixed hearing loss and is unable to use conventional air conduction hearing aids.
ONE of the following conditions
Congenital, surgical, or acquired malformations of the external ear canal or middle ear canal.
Tumors of the external canal and/or tympanic cavity.
BAHD/BAHA for Single-Sided Deafness
BAHD/BAHA is covered for members who are at least 5 years old and meet all criteria below.
ALL of the following
The member is at least 5 years old.
The member has single-sided deafness.
The member has normal bone conduction in the good ear (at least a 25 dB threshold) or only mildly reduced bone conduction in the good ear (26–40 dB), measured at 500 Hz, 1000 Hz, 2000 Hz, and 3000 Hz.
A conventional CROS or (bi)CROS aid, whichever is most appropriate, has been considered and is not a viable option.
A nonpermanent BAHD test band/soft band has been tried and improved the member's word recognition and speech comprehension, particularly in noisy environments.
Auditory Brainstem Implant
Mass General Brigham Health Plan covers unilateral auditory brainstem implants using surface electrodes on the cochlear nuclei when all criteria are met.
ALL of the following
The member has neurofibromatosis type II.
The member is 12 years of age or older.
The member has been rendered deaf due to bilateral resection of the cochlear nerve.
Mass General Brigham Health Plan does not cover hearing or listening devices, or device features, that are principally used for convenience and are not medically necessary. Devices or device features considered experimental and investigational are also not covered, including semi-implantable and fully implantable middle ear hearing aids.
BAHD/BAHA is not covered for any reason other than the indications listed in these coverage criteria, including conditions or diagnoses not covered under these criteria. Pure bilateral sensorineural hearing loss is excluded.
Auditory brainstem implants are not covered for any reason other than the unilateral implant indication listed above, or for conditions or diagnoses not covered under these coverage criteria.
Prior authorization is required for air conduction hearing aids, non-implantable bone conduction hearing aids, bone-anchored hearing devices/aids, and auditory brainstem implants. Prior authorization is not required for cochlear implants. The specialist and/or primary care provider must provide all necessary clinical information, including the presenting condition, history of hearing loss, and medical-necessity rationale, for benefit determination.
Non-medically necessary accessories are excluded, including Bluetooth accessories, accessories for recreational use, accessories for water use, and duplicate accessories. Convenience-use devices or features and experimental or investigational devices or features are not covered.
Replacement or repair of a BAHD/BAHA processor is not covered when the processor remains under the manufacturer's warranty; when it is lost, stolen, or damaged due to improper care, misuse, or neglect; or when the member has a functioning model and a newer or upgraded model is not medically necessary. Mass General Brigham Health Plan may require proof of a stolen or damaged item, such as a police report, pictures, or a corroborating statement.