Loading...

    Explore
    • Policy Monitoring
    • Live Policy Feed
    • Billing Codes
    • Healthcare Providers
    • Health Insurance Payers
    • States
    • Service Lines
    • Taxonomy Codes
    Lookup tools
    • Billing Code Lookup
    • CPT Modifier Lookup
    • Provider Taxonomy Code Lookup
    • Healthcare Provider & Facility Lookup
    • Health Insurance Payer Lookup
    • Payer Contact Directory

    Policy & Benchmark Tools

    • Prior Authorization Lookup
    • Coverage Criteria Lookup
    • Timely Filing Lookup
    • Billing Code Reimbursement Rates
    • Payer Comparison Dashboard
    • Facility Comparison Dashboard
    • All tools

    Company

    • About OpenPayer
    • Data Sources
    • Request a Policy / Feedback
    • Trek Health
    OpenPayerby Trek Health
    LinkedInYouTube

    © 2026 Trek Health. All rights reserved.

    OpenPayer is built and maintained by Trek Health.

    v1.0.32
    OpenPayerPolicy UpdatesEndocrinologyBCBS Rhode Island CGM Coverage | OpenPayer
    Ask Trek AI about this page
    ModifiedBlue Cross Blue Shield - Rhode IslandPolicy N/A

    Continuous Glucose Monitor Coverage

    Customize your policy alerts

    Sign up for all Blue Cross Blue Shield - Rhode Island policy alerts

    Know when Blue Cross Blue Shield - Rhode Island releases new policies or updates existing guidance.

    Monitor payer policy activity

    Receive email alerts as soon as relevant payer policies are published or updated.

    This policy governs coverage, medical necessity, and authorization requirements for implantable and non-implantable continuous glucose monitors for Commercial and Medicare Advantage members. Home blood glucose monitors are outside the scope of this policy.

    Policy Summary
    PayerBlue Cross Blue Shield - Rhode Island
    PolicyContinuous Glucose Monitor Coverage
    Policy CodePolicy N/A
    Change TypeModified
    Effective DateOct 1, 2025
    Last ReviewSep 3, 2025
    Next Review DateN/A
    Key ActionObtain prior authorization through the online tool for implantable CGM use in Medicare Advantage Plans.
    SourceLink

    OpenPayer is powered by Trek Health's payer performance platform. Trek continuously ingests, validates, and normalizes Transparency in Coverage data alongside payer policies and other commercial payer data to create a structured payer intelligence foundation. OpenPayer uses this foundation to deliver personalized search results, dynamically generated policy pages, and tailored policy monitoring based on each user's payers, specialties, billing codes, and areas of interest. The same intelligence powers broader payer performance workflows, including reimbursement benchmarking, contract evaluation, payer negotiations, and financial decision-making.

    POLICY UPDATE CHANGES

    Authorization is no longer required for specified non-implantable CGMs obtained through retail pharmacy or durable medical equipment channels for Commercial Products.

    CoveredNon-implantable CGMs covered
    RequiredMedicare Advantage implantable CGM authorization
    Not requiredMedicare Advantage non-implantable CGM authorization
    18+Commercial implantable CGM minimum age
    90 daysMaximum CGM supply billing period

    Medical Necessity and Coverage Criteria

    Medicare Advantage I-CGM

    For Medicare Advantage Plans, implantable continuous glucose monitoring (I-CGM) may be considered medically necessary when the applicable CMS medical-necessity criteria in the web-based tool are met.

    The medical-necessity criteria in the CMS web-based tool are met.

    Use the online medical-criteria tool for participating providers.

    Commercial I-CGM — Initial Therapy

    Commercial Products: I-CGM monitoring of glucose levels in interstitial fluid as an adjunct to standard care may be considered medically necessary when ALL of the following are met.

    ALL of the following

    • The individual is 18 years of age or older.
    • The individual has been diagnosed with diabetes mellitus of any type.
    • Insulin injections are required multiple times daily, or the individual uses an insulin pump for maintenance of blood sugar control.
    • Both of the following

      • The individual or caregiver demonstrates all of the following

        • An understanding of the technology, including use of the device to recognize alerts and alarms.
        • Motivation to use the device correctly and consistently.
        • Continued participation in a comprehensive diabetes treatment plan.
      • Despite ongoing management using self-monitoring and insulin administration regimens to optimize care, at least one of the following is present

        • Inadequate glycemic control, demonstrated by HbA1c measurements above target.
        • Persistent fasting hyperglycemia.

    Commercial I-CGM — Continued Use

    Commercial Products: Continued I-CGM use may be considered medically necessary when BOTH of the following are documented.

    BOTH of the following

    • The individual has used the device as intended.
    • The device has resulted in the desired clinical benefit.

      Examples include improved HbA1c control or fewer episodes of symptomatic hypoglycemia or hyperglycemia.

    Non-Implantable CGM Coverage

    Non-implantable CGM devices defined as either adjunctive or non-adjunctive are covered for Medicare Advantage Plans and Commercial Products.

    Coverage applies to

    • Adjunctive CGM devices, which require the user to verify glucose levels or trends displayed by the CGM with a blood glucose monitor before making treatment decisions.
    • Non-adjunctive CGM devices, which may be used to make treatment decisions without a stand-alone blood glucose monitor to confirm testing results.
    • For Medicare Advantage Plans, Medicare-approved CGM devices do not require authorization and may be obtained through either the Durable Medical Equipment (DME) benefit or the Pharmacy benefit when the member has pharmacy benefits through BCBSRI.
    • For Commercial Products, Dexcom and Abbott FreeStyle Libre branded non-implantable CGM devices may be obtained through retail pharmacies through BCBSRI's Pharmacy Benefit Management Program vendor. Effective October 1, 2025, authorization is not required and coverage is through the member's pharmacy benefit; devices may also be obtained through a DME provider without authorization under the member's DME benefit.

    Medicare Advantage CGM Medical-Necessity Indications

    For Medicare Advantage Plans, a CGM is intended for an individual diagnosed with diabetes mellitus. The treating practitioner should conclude that the individual or caregiver has sufficient training in CGM use, and the CGM must be prescribed in accordance with FDA indications for use to improve glycemic control.

    All foundational requirements

    • The individual has been diagnosed with diabetes mellitus.
    • The treating practitioner concludes that the individual or caregiver has sufficient training in use of a CGM.
    • The CGM is prescribed in accordance with FDA indications for use to improve glycemic control.
    • At least one applicable indication

      • The individual is insulin-treated.

    Implantable CGM Insertion — Medicare Advantage Plans

    For Medicare Advantage Plans, insertion of an implantable interstitial glucose sensor is medically necessary when the applicable criteria in the web-based tool have been met.

    The applicable Medicare Advantage I-CGM medical-necessity criteria in the web-based tool are met.

    Applies to CPT 0446T, including creation of the subcutaneous pocket, sensor insertion, system activation, and patient training.

    Implantable CGM Insertion — Commercial Products

    For Commercial Products, insertion of an implantable interstitial glucose sensor is medically necessary when the applicable Commercial I-CGM medical criteria have been met.

    The applicable Commercial I-CGM medical-necessity criteria are met.

    Applies to CPT 0446T, including creation of the subcutaneous pocket, sensor insertion, system activation, and patient training.

    Removal of Implantable Sensor

    Removal of an implantable interstitial glucose sensor is medically necessary for Medicare Advantage Plans and Commercial Products when the criteria in the Removal of Implantable Devices policy are met.

    The applicable criteria in the Removal of Implantable Devices policy are met.

    Applies to CPT 0447T: removal of an implantable interstitial glucose sensor from a subcutaneous pocket via incision.

    Replacement of Implantable Sensor

    Replacement of an implantable sensor may be considered medically necessary under the applicable product-specific criteria.

    Medicare Advantage Plans

    • The applicable Medicare Advantage I-CGM medical criteria are met.
    • The applicable criteria in the Removal of Implantable Devices policy are met.
    • The replacement procedure meets the product-specific medical criteria.

      Applies to CPT 0448T: removal of the implantable sensor with creation of a subcutaneous pocket at a different anatomic site and insertion of a new implantable sensor, including system activation.

    Commercial Products

    • The applicable criteria in the Removal of Implantable Devices policy are met.

    Ambulatory Continuous Glucose Monitoring Services

    The following ambulatory continuous glucose monitoring services are covered for Medicare Advantage Plans and Commercial Products.

    Covered services

    • CPT 95249 — Ambulatory continuous glucose monitoring of interstitial tissue fluid via a subcutaneous sensor for a minimum of 72 hours; patient-provided equipment, sensor placement, hook-up, calibration of monitor, patient training, and printout of recording.
    • CPT 95250 — Ambulatory continuous glucose monitoring of interstitial tissue fluid via a subcutaneous sensor for a minimum of 72 hours; sensor placement, hook-up, calibration of monitor, patient training, removal of sensor, and printout of recording.
    • CPT 95251 — Interpretation and report for ambulatory continuous glucose monitoring of interstitial tissue fluid via a subcutaneous sensor for a minimum of 72 hours.

    Home blood glucose monitors are outside the scope of this policy. See the Related Policies section for information about home blood glucose monitors.

    Reflectance colorimeter devices used to measure blood glucose levels in clinical settings are not covered as durable medical equipment for use in the home because the need for frequent professional recalibration makes them unsuitable for home use.

    For the following HCPCS codes, coverage differs by product line: A9276, A9277, A9278, S1030, and S1031 are not covered for Medicare Advantage Plans according to CMS and are covered for Commercial Products. Codes A9276–A9278 are not used to bill supplies used with E2102 (adjunctive, non-implanted CGM or receiver) or E2103 (non-adjunctive, non-implanted CGM or receiver).

    For Medicare Advantage Plans, the following supply codes are not covered according to CMS: A9276 (disposable invasive sensor), A9277 (external transmitter), A9278 (external receiver), S1030 (continuous non-invasive glucose monitoring device, purchase), and S1031 (continuous non-invasive glucose monitoring device, rental, including sensor, sensor replacement, and download to monitor). These codes are covered for Commercial Products.

    For Commercial Products, use of an I-CGM device that does not meet the applicable medical criteria is considered not medically necessary.

    Covered, Noncovered, and Billing Codes

    Covered HCPCS CodesHCPCSCovered
    A4239Supply allowance for non-adjunctive, non-implanted continuous glucose monitor (CGM), includes all supplies and accessories, 1 month supply = 1 unit of service
    E2103Non-adjunctive, non-implanted continuous glucose monitor or receiver
    Covered HCPCS CodesHCPCSCovered
    A4238Supply allowance for adjunctive, non-implanted continuous glucose monitor (CGM), includes all supplies and accessories, 1 month supply = 1 unit of service
    E2102Adjunctive, non-implanted continuous glucose monitor or receiver
    Not Covered for Medicare Advantage PlansHCPCSNot Covered
    A9276Sensor; invasive (e.g., subcutaneous), disposable, for use with non-durable medical equipment interstitial continuous glucose monitoring system, one unit = 1 day supply
    A9277Transmitter; external, for use with non-durable medical equipment interstitial continuous glucose monitoring system
    A9278Receiver (monitor); external, for use with non-durable medical equipment interstitial continuous glucose monitoring system
    S1030Continuous non-invasive glucose monitoring device, purchase (for physician interpretation of data, use CPT code)
    S1031Continuous non-invasive glucose monitoring device, rental, including sensor, sensor replacement, and download to monitor (for physician interpretation of data, use CPT code)
    Covered for Commercial ProductsHCPCSCovered
    A9276Sensor; invasive (e.g., subcutaneous), disposable, for use with non-durable medical equipment interstitial continuous glucose monitoring system, one unit = 1 day supply
    A9277Transmitter; external, for use with non-durable medical equipment interstitial continuous glucose monitoring system
    A9278Receiver (monitor); external, for use with non-durable medical equipment interstitial continuous glucose monitoring system
    S1030Continuous non-invasive glucose monitoring device, purchase (for physician interpretation of data, use CPT code)
    S1031Continuous non-invasive glucose monitoring device, rental, including sensor, sensor replacement, and download to monitor (for physician interpretation of data, use CPT code)
    Covered CPT CodesCPTCovered
    0446TCreation of subcutaneous pocket with insertion of implantable interstitial glucose sensor, including system activation and patient training
    Not Covered HCPCS CodesHCPCSNot Covered
    A4244Alcohol or peroxide
    A4245Alcohol or peroxide
    A4246Betadine
    A4247PhisoHex
    A4250Urine test reagent strips or tablets
    A9270Glucose monitors not designed for use in the home
    A9275Home blood glucose disposable monitor, including test strips
    Required ModifiersModifier
    KXModifier for insulin-treated member; use when the member is treated with insulin injections. Do not use for a member who is not treated with insulin injections.
    KSModifier for non-insulin-treated member; use when the member is not treated with insulin injections.
    Covered HCPCS CodesHCPCSCovered
    A4253Test strips
    A4259Lancets
    Not Covered for Medicare Advantage PlansHCPCSNot Covered
    A9276Sensor; invasive (e.g., subcutaneous), disposable, for use with non-durable medical equipment interstitial continuous glucose monitoring system, one unit = 1 day supply
    A9277Transmitter; external, for use with non-durable medical equipment interstitial continuous glucose monitoring system
    A9278Receiver (monitor); external, for use with non-durable medical equipment interstitial continuous glucose monitoring system
    S1030Continuous non-invasive glucose monitoring device, purchase (for physician interpretation of data, use CPT code)
    S1031Continuous non-invasive glucose monitoring device, rental, including sensor, sensor replacement, and download to monitor (for physician interpretation of data, use CPT code)
    Covered for Commercial ProductsHCPCSCovered
    A9276Sensor; invasive (e.g., subcutaneous), disposable, for use with non-durable medical equipment interstitial continuous glucose monitoring system, one unit = 1 day supply
    A9277Transmitter; external, for use with non-durable medical equipment interstitial continuous glucose monitoring system
    A9278Receiver (monitor); external, for use with non-durable medical equipment interstitial continuous glucose monitoring system
    S1030Continuous non-invasive glucose monitoring device, purchase (for physician interpretation of data, use CPT code)
    S1031Continuous non-invasive glucose monitoring device, rental, including sensor, sensor replacement, and download to monitor (for physician interpretation of data, use CPT code)
    Referenced HCPCS CodesHCPCS
    E2102Adjunctive, non-implanted CGM or receiver
    E2103Non-adjunctive, nonimplanted CGM or receiver
    Covered CPT CodesCPTCovered
    0446TCreation of subcutaneous pocket with insertion of implantable interstitial glucose sensor, including system activation and patient training
    Covered CPT CodesCPTCovered
    0446TCreation of subcutaneous pocket with insertion of implantable interstitial glucose sensor, including system activation and patient training
    Covered CPT CodesCPTCovered
    0447TRemoval of implantable interstitial glucose sensor from subcutaneous pocket via incision
    Covered CPT CodesCPTCovered
    0448TRemoval of implantable interstitial glucose sensor with creation of subcutaneous pocket at different anatomic site and insertion of new implantable sensor, including system activation
    Covered CPT CodesCPTCovered
    95249Ambulatory continuous glucose monitoring of interstitial tissue fluid via a subcutaneous sensor for a minimum of 72 hours; patient-provided equipment, sensor placement, hook-up, calibration of monitor, patient training, and printout of recording
    95250Ambulatory continuous glucose monitoring of interstitial tissue fluid via a subcutaneous sensor for a minimum of 72 hours; sensor placement, hook-up, calibration of monitor, patient training, removal of sensor, and printout of recording
    95251Ambulatory continuous glucose monitoring of interstitial tissue fluid via a subcutaneous sensor for a minimum of 72 hours; interpretation and report
    ModifierModifier
    25Significant, separately identifiable E&M service by the same physician or other qualified health care professional on the same day of the procedure or other service
    Commercial implantable CGM age requirement
    Minimum age18 years of age or older
    Product typeCommercial implantable CGM (I-CGM)
    Criteria structureAll stated initial-therapy criteria must be met
    Commercial implantable CGM HbA1c criterion

    Authorization, Documentation, and Billing Guidance

    Prior Authorization

    Medicare Advantage Prior Authorization Required

    Prior authorization is required for Medicare Advantage use of an implantable continuous glucose monitor (I-CGM). Participating providers must obtain authorization through the online tool.

    Prior Authorization

    Commercial Prior Authorization Recommended

    Prior authorization is recommended for Commercial Products when an I-CGM is used. Participating providers should submit the request through the online tool.

    Billing Rule

    Meet Web-Based Tool Criteria

    Continuous Glucose Monitoring Overview

    Continuous glucose monitors measure glucose in interstitial fluid and may be implantable or non-implantable. Implantable CGM coverage is tied to diabetes management, intensive insulin therapy, the individual's or caregiver's ability and motivation to use the technology, and clinically significant glycemic-control problems despite ongoing management.

    Adjunctive CGMs require confirmation with a blood glucose monitor before treatment decisions, while nonadjunctive CGMs can be used for treatment decisions without separate blood glucose monitor confirmation. This policy addresses coverage and medical-necessity requirements for both device categories under Medicare Advantage and Commercial Products.

    CGM and Treatment Definitions

    Adjunctive CGM confirmation requirement
    Confirmation requirementGlucose levels or trends displayed by the CGM must be verified with a blood glucose monitor before treatment decisions
    Monitor used for confirmationBlood glucose monitor (BGM)
    Coverage contextAdjunctive non-implantable CGM is covered for Medicare Advantage and Commercial Products
    Nonadjunctive CGM treatment decisions
    Treatment-decision capabilityCan be used to make treatment decisions without confirmation from a stand-alone blood glucose monitor
    Separate BGM confirmationNot required before treatment decisions
    Policy Summary
    PayerBlue Cross Blue Shield - Rhode Island
    PolicyContinuous Glucose Monitor Coverage
    Policy CodePolicy N/A
    Change TypeModified
    Effective DateOct 1, 2025
    Last ReviewSep 3, 2025
    Next Review DateN/A
    Key ActionObtain prior authorization through the online tool for implantable CGM use in Medicare Advantage Plans.
    SourceLink
    On This Page
    Medical Necessity and Coverage CriteriaCovered, Noncovered, and Billing CodesAuthorization, Documentation, and Billing GuidanceContinuous Glucose Monitoring OverviewCGM and Treatment Definitions
    Recurring episodes of hypoglycemia.
  1. Hypoglycemia unawareness that puts the individual or others at risk.
  2. The individual has a history of problematic, recurrent hypoglycemia that persists despite multiple attempts (more than one) to adjust medication(s) and/or modify the diabetes treatment plan.
  3. The individual has a history of one level 3 hypoglycemic event, defined as glucose <54 mg/dL (3.0 mmol/L), characterized by an altered mental and/or physical state requiring third-party assistance for treatment of hypoglycemia.
  4. The replacement procedure meets the applicable product-specific medical criteria.
    HbA1c criterionMeasurements above target
    Clinical contextInadequate glycemic control despite ongoing self-monitoring and insulin administration
    Qualifying alternativesPersistent fasting hyperglycemia, recurring hypoglycemia, or hypoglycemia unawareness may also qualify
    Insulin-dependent testing-supply limit
    Applicable suppliesTest strips (A4253) and lancets (A4259)
    Insulin-dependent limit500 units per 3 months
    Insulin statusMember is receiving insulin injections to treat diabetes
    Non-insulin-dependent testing-supply limit
    Applicable suppliesTest strips (A4253) and lancets (A4259)
    Non-insulin-dependent limit200 units per 3 months
    TimeframeThree months
    Non-adjunctive CGM supply billing period
    Unit definition1 month supply = 1 unit of service
    Supply codeA4239
    Maximum billable periodUp to a 90-day supply may be billed and reimbursed by BCBSRI
    Adjunctive CGM supply billing period
    Unit definition1 month supply = 1 unit of service
    Supply codeA4238
    Maximum billable periodUp to a 90-day supply may be billed and reimbursed by BCBSRI
    Level 3 hypoglycemic event
    Glucose thresholdLess than 54 mg/dL (3.0 mmol/L)
    Physiologic effectAltered mental and/or physical state
    Treatment requirementThird-party assistance is required for treatment of hypoglycemia
    Minimum CGM monitoring duration
    Minimum monitoring duration72 hours
    Monitoring methodAmbulatory CGM of interstitial tissue fluid via a subcutaneous sensor
    Applicable servicesCodes 95249, 95250, and 95251

    For Medicare Advantage coverage of CPT 0446T, the medical-necessity criteria in the web-based tool must be met.

    • CPT 0446T: insertion of an implantable interstitial glucose sensor, including activation and patient training.

    Unsupported block type: billing_rule

    Documentation Required

    Document Initial I-CGM Eligibility

    Before initiating Commercial I-CGM therapy, document that the member is at least 18 years old, has diabetes mellitus, requires multiple daily insulin injections or uses an insulin pump, and meets the required education, engagement, and glycemic-control criteria.

    • Document understanding of the technology, including alerts and alarms.
    • Document motivation to use the device correctly and consistently and continued participation in a comprehensive diabetes treatment plan.
    • Document inadequate glycemic control, persistent fasting hyperglycemia, recurring hypoglycemia, or hypoglycemia unawareness despite ongoing management.
    Documentation Required

    Document Continued Clinical Benefit

    For continued I-CGM use, document that the individual used the device as intended and that it produced the desired clinical benefit.

    • Examples of benefit include improved HbA1c control or fewer symptomatic hypoglycemic or hyperglycemic episodes.
    Documentation Required

    Retain Documentation for Audit

    Retain all records supporting the billed services and provide them to BCBSRI upon request. Failure to produce requested documentation may result in denial or retraction of payment.

    • BCBSRI may audit services regardless of the provider's participation status.
    Documentation Required

    Document CGM Training and FDA Indication

    For Medicare Advantage CGM coverage, document that the treating practitioner determined the individual or caregiver has sufficient CGM training and that the device is prescribed consistent with an applicable FDA indication.

    • Applicable indications include insulin treatment, problematic recurrent hypoglycemia despite treatment-plan adjustments, or a level 3 hypoglycemic event requiring third-party assistance.
    Billing Rule

    Report Insulin-Treatment Status

    Identify the member's insulin-treatment status on every claim for blood glucose monitoring equipment and related supplies by using the appropriate modifier.

    • Use KX for an insulin-treated member.
    • Use KS for a non-insulin-treated member.
    Documentation Required

    Document Removal-Policy Criteria

    Support implantable-sensor removal or replacement services with documentation showing that the applicable criteria in the Removal of Implantable Devices policy are met.

    • Review and document the related policy criteria before billing CPT 0447T or 0448T.
    Denial Risk

    I-CGM Fails Medical-Necessity Criteria

    I-CGM is not covered when the applicable medical-necessity criteria are not met.

    • Medicare Advantage: coverage requires meeting the medical criteria in the web-based tool.
    • Commercial Products: coverage requires meeting the medical criteria in this policy.
    Denial Risk

    Nonessential Cleaning Supplies Not Covered

    Do not bill nonessential cleaning supplies as covered CGM-related items.

    • Alcohol or peroxide: A4244, A4245.
    • Betadine or phisoHex: A4246, A4247.
    Denial Risk

    Urine Reagent Supplies Not Covered

    Urine test reagent strips or tablets are not covered when used in conjunction with a CGM.

    • A4250 is not covered for this use.
    Denial Risk

    Non-Home Glucose Monitors

    Glucose monitors not designed for use in the home must be coded A9270 and will be denied as statutorily not covered because there is no applicable benefit category.

    • Reflectance colorimeter devices used in clinical settings are not covered as home-use durable medical equipment.
    Denial Risk

    Disposable Home Monitors Not Covered

    Home blood glucose disposable monitors, including test strips, are not covered because they do not meet the definition of durable medical equipment.

    • A9275 is not covered.

    Unsupported block type: billing_rule

    Unsupported block type: denial_risk

    Unsupported block type: billing_rule

    Unsupported block type: billing_rule

    Unsupported block type: billing_rule

    Coverage context
    Nonadjunctive non-implantable CGM is covered for Medicare Advantage and Commercial Products
    Adjunctive CGM definition
    DefinitionA CGM that requires verification of displayed glucose levels or trends before treatment decisions
    Required verification deviceBlood glucose monitor (BGM)
    Use limitationTreatment decisions should follow BGM confirmation
    Non-adjunctive CGM definition
    DefinitionA CGM that can be used to make treatment decisions without confirmation from a stand-alone blood glucose monitor
    Stand-alone BGM confirmationNot required
    Device categoryNon-adjunctive CGM
    Insulin-treated definition
    Insulin-treatedMember receiving insulin injections to treat diabetes
    Oral medications aloneDo not qualify as insulin treatment
    Insulin formulationInsulin does not exist in an oral form
    Real-time CGM (rtCGM)
    AbbreviationrtCGM
    Data providedReal-time glucose level and glucose trend data
    Trend informationDirection and rate-of-change data
    Intermittently viewed CGM (iCGM)
    AbbreviationiCGM
    Display patternContinuous glucose measurements are displayed retrospectively or intermittently
    Alternate nameFlash-glucose monitor (FGM)