Loading...

    Explore
    • Policy Monitoring
    • Live Policy Feed
    • Billing Codes
    • Healthcare Providers
    • Health Insurance Payers
    • States
    • Service Lines
    • Taxonomy Codes
    Lookup tools
    • Billing Code Lookup
    • CPT Modifier Lookup
    • Provider Taxonomy Code Lookup
    • Healthcare Provider & Facility Lookup
    • Health Insurance Payer Lookup
    • Payer Contact Directory

    Policy & Benchmark Tools

    • Prior Authorization Lookup
    • Coverage Criteria Lookup
    • Timely Filing Lookup
    • Billing Code Reimbursement Rates
    • Payer Comparison Dashboard
    • Facility Comparison Dashboard
    • All tools

    Company

    • About OpenPayer
    • Data Sources
    • Request a Policy / Feedback
    • Trek Health
    OpenPayerby Trek Health
    LinkedInYouTube

    © 2026 Trek Health. All rights reserved.

    OpenPayer is built and maintained by Trek Health.

    v1.0.32
    OpenPayerPolicy UpdatesClinical/Medical PolicyBCBS North Dakota LAA Closure Coverage | OpenPayer
    Ask Trek AI about this page
    CurrentBlue Cross Blue Shield - North DakotaPolicy 195

    Left-Atrial Appendage Closure Devices for Stroke Prevention in Atrial Fibrillation

    Customize your policy alerts

    Sign up for Blue Cross Blue Shield - North Dakota Policy 195 alerts

    Get alerted when Policy 195 changes without checking for updates manually.

    Monitor payer policy activity

    Receive email alerts as soon as relevant payer policies are published or updated.

    Coverage of percutaneous left atrial appendage closure devices as an alternative to long-term anticoagulation for stroke prevention in atrial fibrillation, limited to specified devices and clinical criteria.

    Policy Summary
    PayerBlue Cross Blue Shield - North Dakota
    PolicyLeft-Atrial Appendage Closure Devices for Stroke Prevention in Atrial Fibrillation
    Policy CodePolicy 195
    Change TypeNo material change
    Effective DateMarch 1, 2026
    Last ReviewJan 1, 2026
    Next Review DateNovember 1, 2026
    Key ActionSubmit the required clinical and device documentation for medical necessity review.
    SourceLink
    POLICY UPDATE CHANGES

    No material clinical or coverage changes in this revision.

    2Covered devices
    2Coverage conditions

    OpenPayer is powered by Trek Health's payer performance platform. Trek continuously ingests, validates, and normalizes Transparency in Coverage data alongside payer policies and other commercial payer data to create a structured payer intelligence foundation. OpenPayer uses this foundation to deliver personalized search results, dynamically generated policy pages, and tailored policy monitoring based on each user's payers, specialties, billing codes, and areas of interest. The same intelligence powers broader payer performance workflows, including reimbursement benchmarking, contract evaluation, payer negotiations, and financial decision-making.

    0-9
    Bleeding risk score range
    5%/yrUntreated atrial fibrillation stroke incidence

    Medical Necessity and Investigational Use

    Medically Necessary Percutaneous Closure

    Percutaneous left atrial appendage closure is medically necessary for stroke prevention in patients with atrial fibrillation when ALL of the following criteria are met:

    ALL of the following

    • The patient has an increased risk of stroke and systemic embolism based on a CHADS2 or CHA2DS2-VASc score, and systemic anticoagulation therapy is recommended.
    • Clinical documentation establishes that the patient is suitable for short-term anticoagulation but unable to take long-term oral anticoagulation.

    WATCHMAN or Amplatzer Amulet Coverage

    Coverage may be considered medically necessary when ALL of the following are met:

    ALL of the following

    • The device is a WATCHMAN or Amplatzer Amulet left atrial appendage closure device.
    • The procedure is performed for prevention of stroke in a patient with atrial fibrillation.
    • The patient meets the required stroke and systemic embolism risk and anticoagulation criteria.
    • The patient is suitable for short-term anticoagulation but unable to take long-term oral anticoagulation.

    Investigational Use

    Left atrial appendage closure is investigational when ANY of the following applies:

    ANY of the following

    • A device other than WATCHMAN or Amplatzer Amulet is used.
    • The required medical necessity criteria are not met, including insufficient documented stroke and systemic embolism risk or lack of a recommendation for systemic anticoagulation.
    • The patient is not documented to be suitable for short-term anticoagulation while being unable to take long-term oral anticoagulation.

    The use of any device other than the WATCHMAN or Amplatzer Amulet device for left atrial appendage closure is considered investigational.

    Left atrial appendage closure is considered investigational when the required medical necessity criteria are not met. There is not enough research to show that these devices improve health outcomes when policy criteria are not met.

    No evidence-based practice guidelines recommend the use of left atrial appendage closure devices other than the WATCHMAN or Amplatzer Amulet device. Accordingly, nonqualifying devices are excluded from medically necessary coverage.

    Procedure, Device, and Risk-Score Coding Information

    Procedure CodesCPT
    33340Percutaneous transcatheter closure of the left atrial appendage with endocardial implant, including fluoroscopy, transseptal puncture, catheter placement(s), left atrial angiography, left atrial appendage angiography, when performed, and radiological supervision and interpretation
    33268Open exclusion of left atrial appendage performed at the time of other sternotomy or thoracotomy procedure
    33269Thoracoscopic exclusion of left atrial appendage
    HCPCSHCPCS
    93799Unlisted cardiovascular service or procedure
    CHADS2 score
    High stroke-risk thresholdA CHADS2 score of 2 or greater is considered high risk of stroke.
    Anticoagulation recommendationOral anticoagulation is recommended for patients with atrial fibrillation who are at high risk of stroke, including those with a CHADS2 score of 2 or greater.
    Lower stroke riskPatients with lower stroke risk require a more individualized choice of antithrombotic therapy.
    HAS-BLED score
    Score rangeHAS-BLED scores range from 0 to 9.
    High bleeding riskA score of 3 or greater is associated with high bleeding risk.

    Documentation and Coverage Review Requirements

    Documentation Required

    Submit Documentation for Medical Necessity Review

    Submit the required information for medical necessity review so Blue Cross Blue Shield of North Dakota can determine whether the policy criteria are met. Missing documentation may affect the review and coverage decision.

    Documentation Required

    Required Clinical and Device Documentation

    Include complete clinical and device documentation supporting the request, including the patient’s history and physical or chart notes and identification of the FDA-approved device to be used.

    • History and physical or chart notes
    • FDA-approved device identification
    • Documentation of increased stroke and systemic embolism risk based on a CHADS2 or CHA2DS2-VASc score and that systemic anticoagulation is recommended
    • Documentation that the long-term risks of systemic anticoagulation outweigh the risks of device implantation

    Clinical Background

    Atrial fibrillation can cause blood stasis in the left atrium, with the left atrial appendage being the area at greatest risk for thrombus formation. Thrombi that form in the appendage can contribute to stroke and systemic embolism. Stroke prevention is primarily managed with systemic anticoagulation, but anticoagulation may create bleeding risks and require monitoring or dose adjustments. Percutaneous left atrial appendage closure is intended to occlude the appendage, reduce thrombus formation, and provide a nonpharmacologic alternative for appropriately selected patients.

    Clinical Risk and Anatomy Definitions

    Left atrial appendage (LAA)
    Anatomical locationThe left atrial appendage is an appendage of the left atrium.
    Blood flow during atrial fibrillationDuring atrial fibrillation, the LAA has the lowest blood flow in the left atrium.
    Thrombus relevanceThe LAA has the highest risk of thrombosis and is responsible for an estimated 90% of left atrial thrombi.
    CHADS2
    PurposeCHADS2 is a score used to stratify stroke risk in patients with atrial fibrillation.
    Heart failureOne point is assigned for heart failure.
    Hypertension
    Policy Summary
    PayerBlue Cross Blue Shield - North Dakota
    PolicyLeft-Atrial Appendage Closure Devices for Stroke Prevention in Atrial Fibrillation
    Policy CodePolicy 195
    Change TypeNo material change
    Effective DateMarch 1, 2026
    Last ReviewJan 1, 2026
    Next Review DateNovember 1, 2026
    Key ActionSubmit the required clinical and device documentation for medical necessity review.
    SourceLink
    On This Page
    Medical Necessity and Investigational UseProcedure, Device, and Risk-Score Coding InformationDocumentation and Coverage Review RequirementsClinical BackgroundClinical Risk and Anatomy Definitions
    Clinical implicationHigher scores may signal the need for closer monitoring of adverse risks and international normalized ratios, or differential dosing of oral anticoagulants or aspirin.
    Denial Risk

    Noncovered Device or Unmet Criteria

    Use of any device other than WATCHMAN or Amplatzer Amulet, or use when the medical policy criteria are not met, is considered investigational. The device selection and supporting documentation should be verified before the procedure is performed.

    • Qualifying devices: WATCHMAN or Amplatzer Amulet
    • Other left atrial appendage closure devices are nonqualifying and investigational
    • Criterion I requires increased stroke and systemic embolism risk with recommended systemic anticoagulation, plus suitability for short-term but inability to take long-term oral anticoagulation
    Denial Risk

    Criteria Not Met or Nonqualifying Device

    If the policy criteria are not met or the device is nonqualifying, coverage may be denied or the procedure may be classified as investigational. Evidence and guidelines do not support coverage for nonqualifying devices or procedures performed when the criteria are unmet.

    • Confirm all medical necessity criteria before requesting or performing the procedure
    • Confirm the requested device is WATCHMAN or Amplatzer Amulet
    • Address any missing clinical or device documentation before review
    One point is assigned for hypertension.
    AgeOne point is assigned for age 75 years or older.
    DiabetesOne point is assigned for diabetes.
    Prior stroke or transient ischemic attackOne point is assigned for prior stroke or transient ischemic attack.
    Risk interpretationA CHADS2 score of 2 or greater identifies high stroke risk in the cited guideline discussion.
    CHA2DS2-VASc
    PurposeCHA2DS2-VASc is an expanded stroke-risk score used in patients with atrial fibrillation.
    Relationship to CHADS2It includes the risk factors used in the CHADS2 score.
    SexThe score adds sex as a risk factor.
    Age categoriesThe score includes additional age categories beyond the CHADS2 age criterion.
    Vascular diseaseThe score adds the presence of vascular disease as a risk factor.
    HAS-BLED
    PurposeHAS-BLED is a bleeding-risk score validated to assess the annual risk of significant bleeding in patients with atrial fibrillation treated with warfarin.
    Score rangeThe score ranges from 0 to 9.
    HypertensionThe score incorporates hypertension.
    Renal or liver functionThe score incorporates abnormal renal or liver function.
    Prior stroke or bleedingThe score incorporates a history of stroke or bleeding.
    Labile international normalized ratiosThe score incorporates labile international normalized ratios (INRs).
    Age and drug or alcohol useThe score incorporates age and drug or alcohol use.