Loading...

    Explore
    • Policy Monitoring
    • Live Policy Feed
    • Billing Codes
    • NPI Medicare & Medicaid
    • Healthcare Providers
    • Health Insurance Payers
    • States
    • Service Lines
    • Taxonomy Codes
    Lookup tools
    • Billing Code Lookup
    • CPT Modifier Lookup
    • Provider Taxonomy Code Lookup
    • Healthcare Provider & Facility Lookup
    • Health Insurance Payer Lookup
    • Payer Contact Directory

    Policy & Benchmark Tools

    • Prior Authorization Lookup
    • Coverage Criteria Lookup
    • Timely Filing Lookup
    • Billing Code Reimbursement Rates
    • Payer Comparison Dashboard
    • Facility Comparison Dashboard
    • All tools

    Company

    • About OpenPayer
    • Data Sources
    • Trek Health
    OpenPayerby Trek Health
    LinkedInYouTube

    © 2026 Trek Health. All rights reserved.

    OpenPayer is built and maintained by Trek Health.

    v1.0.28
    OpenPayerPolicy UpdatesEndocrinologyUnitedHealthcare CGM Insulin Pump Coverage Update …
    Ask Trek AI about this page
    ModifiedUnitedHealthcarePolicy CS024NE.AD

    Continuous Glucose Monitoring and Insulin Delivery for Managing Diabetes (for Nebraska Only)

    Customize your policy alerts

    Sign up for UnitedHealthcare Policy CS024NE.AD alerts

    Get alerted when Policy CS024NE.AD changes without checking for updates manually.

    Monitor payer policy activity

    Receive email alerts as soon as relevant payer policies are published or updated.

    This policy governs medical necessity criteria, coverage rationale, and coding for continuous glucose monitoring (CGM) devices and insulin delivery systems for UnitedHealthcare members in Nebraska.

    OpenPayer is powered by Trek Health's payer performance platform. Trek continuously ingests, validates, and normalizes Transparency in Coverage data alongside payer policies and other commercial payer data to create a structured payer intelligence foundation. OpenPayer uses this foundation to deliver personalized search results, dynamically generated policy pages, and tailored policy monitoring based on each user's payers, specialties, billing codes, and areas of interest. The same intelligence powers broader payer performance workflows, including reimbursement benchmarking, contract evaluation, payer negotiations, and financial decision-making.

    Policy Summary
    PayerUnitedHealthcare
    PolicyContinuous Glucose Monitoring and Insulin Delivery for Managing Diabetes (for Nebraska Only)
    Policy CodePolicy CS024NE.AD
    Change TypeState-referenced criteria updates and removal of long-term CGM criteria
    Effective DateAug 1, 2026
    Last ReviewAug 1, 2026
    Next Review DateN/A
    Key ActionRefer to Nebraska DHHS Code and Heritage Health Plan advisory for state-specific medical necessity criteria and prior authorization requirements.
    SourceLink
    POLICY UPDATE CHANGES

    Replaced instruction to refer to the Nebraska Department of Health and Human Services Code for external insulin pumps with instruction to refer for medical necessity clinical coverage criteria.

    Updated instruction to refer to Nebraska Department of Health and Human Services Code for medical necessity clinical coverage criteria of continuous glucose monitors.

    Removed previous long-term CGM coverage criteria and replaced with instruction to refer to Nebraska Heritage Health Plan advisory for medical necessity criteria.

    Updated Clinical Evidence and References sections to reflect the most current information.

    NEState-specific application
    CGM & pumpsDevice types addressed
    CPT/HCPCS/ICD-10Coding included
    NE DHHSState regulation cross-reference
    PMCF citedEversense evidence summarized
    91% / 75%Sensor life achievement

    Coverage Criteria and Rationale

    Coverage Rationale and State-Specific Criteria

    Coverage is determined using Nebraska-specific DHHS criteria and the policy's coverage rationale.

    State application: Policy applies only to State of Nebraska and follows Nebraska DHHS criteria for insulin pumps and CGMs.

    See Nebraska DHHS Code references cited in document

    State-referenced medical necessity: For medical necessity clinical coverage criteria of external insulin pumps, refer to Nebraska Department of Health and Human Services, Code § 471-7-004.02(EE): Insulin Infusion Pumps, External; for continuous glucose monitors, refer to Nebraska Department of Health and Human Services, Code § 471-7-004.02(Q): Continuous Glucose Monitors (CGM).

    Providers must follow the referenced state codes for criteria details.

    Devices considered not medically necessary: Nonprogrammable transdermal insulin delivery systems (e.g., V-Go) and implantable insulin pumps are considered unproven and not medically necessary due to insufficient evidence of safety and efficacy.

    Applies per policy exclusions and evidence summaries.

    Long-term CGM delegation: Long-term CGM (>14 days) medical necessity clinical coverage criteria are governed by Nebraska DHHS Heritage Health Plan: Health Plan Advisory 24-15.>14 days

    Refer to Heritage Health Plan advisory for clinical criteria

    Short-Term CGM (Professional) Coverage

    Short-term CGM use

    Short-term CGM (3-14 days): Short-term continuous glucose monitoring (professional/clinic-placed) worn for a discrete diagnostic period (generally 3–14 days) by a healthcare provider is proven and medically necessary for management of individuals with diabetes.3-14 days

    Clinic-owned (professional) CGM; used for assessment of glycemic patterns; devices may be blinded or visible.

    Evidence-based coverage considerations

    Covered when supported by clinical evidence and applicable benefit language; document summarizes clinical evidence for insulin pumps and CGM systems and highlights limitations.

    Insulin delivery considerations: Professional societies indicate insulin pumps may be considered for insulin-deficient diabetes due to other causes (e.g., cystic fibrosis–related diabetes, post-transplantation, post-pancreatectomy) though evidence is limited.

    (ADA, 2025; McCall et al., 2023)

    Implantable insulin pumps are available only in clinical trial settings and are not commercially available for routine coverage.

    See clinical trial availability and lack of FDA-approved implantable pumps.

    Nonprogrammable transdermal insulin delivery: There is insufficient evidence demonstrating the safety and efficacy of nonprogrammable wearable disposable insulin delivery devices (e.g., V-Go); further well-designed long-term comparative studies are needed.

    Observational and retrospective studies report HbA1c improvements but are limited by design and attrition (Grunberger et al., 2020; others).

    State-specific coverage delegation (Nebraska)

    Coverage and medical necessity determinations reference state-specific criteria for Nebraska.

    State-referenced coverage delegation: Medical necessity clinical coverage criteria for external insulin pumps and continuous glucose monitors are determined by referring to Nebraska Department of Health and Human Services Code § 471-7-004.02(EE) and § 471-7-004.02(Q), respectively; long-term (>14 days) CGM criteria are delegated to Heritage Health Plan: Health Plan Advisory 24-15.

    Providers must follow the referenced state codes/advisories for criteria details and documentation requirements.

    This policy considers nonprogrammable transdermal insulin delivery systems (for example, V-Go) and implantable insulin pumps to be unproven for management of individuals with diabetes. Clinical evidence is insufficient to demonstrate consistent safety and efficacy for these device classes, and they are therefore listed as not medically necessary under the policy's non–state-specific coverage rationale. Providers should expect coverage denials for these devices unless there is applicable state-specific guidance that explicitly supports medical necessity.

    Implantable insulin pumps are currently available only in clinical trial settings and are not commercially available for routine clinical use. Because these devices are investigational outside of research contexts, implantable insulin pumps are not covered for general clinical care.

    Continuous glucose monitor (CGM) products that are distributed over the counter (OTC) without a prescription (for example, Dexcom Stelo, Abbott Lingo, Abbott Libre Rio) are outside the scope of this policy. OTC CGM products are obtained through retail pharmacies and are not managed via mail-order DME channels; coverage and benefit considerations for OTC CGMs follow applicable pharmacy or benefit rules rather than this DME-oriented policy.

    The policy classifies both implantable insulin pumps and nonprogrammable transdermal insulin delivery systems as unproven. The rationale is limited clinical evidence demonstrating effectiveness compared with standard insulin delivery methods; accordingly these device types are considered not medically necessary for routine diabetes management in this policy.

    Available literature on nonprogrammable wearable disposable insulin delivery devices (for example, V-Go) is limited and of variable quality. Observational and retrospective studies report some HbA1c improvements, but study limitations (lack of control groups, small samples, high attrition) prevent definitive conclusions about safety and effectiveness. Larger, well‑designed prospective studies with long‑term follow up and comparative effectiveness data are needed before these devices can be considered medically necessary.

    There are currently no FDA‑approved implantable insulin pumps. The absence of FDA approval for implantable insulin pumps informs coverage decisions: implantable pumps are not supported as approved devices under this policy and remain limited to investigational or clinical trial contexts.

    Procedure, HCPCS, and Diagnosis Codes

    Procedure CPT CodesCPT
    0446TCreation of subcutaneous pocket with insertion of implantable interstitial glucose sensor, including system activation and patient training
    0448TRemoval of implantable interstitial glucose sensor with creation of subcutaneous pocket at different anatomic site and insertion of new implantable sensor, including system activation.
    95249Ambulatory continuous glucose monitoring of interstitial tissue fluid via a subcutaneous sensor for a minimum of 72 hours; patient-provided equipment, sensor placement, hook-up, calibration of monitor, patient training, and printout of recording.
    95250Ambulatory continuous glucose monitoring of interstitial tissue fluid via a subcutaneous sensor for a minimum of 72 hours; physician or other qualified health care professional (office) provided equipment, sensor placement, hook-up, calibration of monitor, patient training, removal of sensor, and printout of recording.
    95251Ambulatory continuous glucose monitoring of interstitial tissue fluid via a subcutaneous sensor for a minimum of 72 hours; analysis, interpretation and report
    HCPCS / DME CodesHCPCS
    A4226Supplies for maintenance of insulin infusion pump with dosage rate adjustment using therapeutic continuous glucose sensing, per week.
    A4238Supply allowance for adjunctive, nonimplanted continuous glucose monitor (CGM), includes all supplies and accessories, 1 month supply = 1 unit of service.
    A4239Supply allowance for nonadjunctive, nonimplanted continuous glucose monitor (CGM), includes all supplies and accessories, 1 month supply = 1 unit of service.
    A9274External ambulatory insulin delivery system, disposable, each, includes all supplies and accessories.
    A9276Sensor; invasive (e.g., subcutaneous), disposable, for use with nondurable medical equipment interstitial continuous glucose monitoring system (CGM), one unit = 1 day supply.
    A9277Transmitter; external, for use with nondurable medical equipment interstitial continuous glucose monitoring system (CGM).
    A9278Receiver (monitor); external, for use with nondurable medical equipment interstitial continuous glucose monitoring system (CGM).
    E0784External ambulatory infusion pump, insulin.
    E0787External ambulatory infusion pump, insulin, dosage rate adjustment using therapeutic continuous glucose sensing.
    E2102Adjunctive, nonimplanted continuous glucose monitor (CGM) or receiver.
    1–10 of 14
    1/2
    ICD-10 Codes (partial list shown in document)ICD-10
    E11.00Type 2 diabetes mellitus with hyperosmolarity without nonketotic hyperglycemic-hyperosmolar coma (NKHHC).
    E11.01Type 2 diabetes mellitus with hyperosmolarity with coma.
    E11.10Type 2 diabetes mellitus with ketoacidosis without coma.
    E11.11Type 2 diabetes mellitus with ketoacidosis with coma.
    E11.21Type 2 diabetes mellitus with diabetic nephropathy.
    E11.22Type 2 diabetes mellitus with diabetic chronic kidney disease.
    E11.29Type 2 diabetes mellitus with other diabetic kidney complication.
    E11.311Type 2 diabetes mellitus with unspecified diabetic retinopathy with macular edema.
    E11.319Type 2 diabetes mellitus with unspecified diabetic retinopathy without macular edema.
    E11.3211Type 2 diabetes mellitus with mild nonproliferative diabetic retinopathy with macular edema, right eye.
    1–10 of 15
    1/2
    Applicable ICD-10 Diagnosis CodesICD-10
    E11.3552Type 2 diabetes mellitus with proliferative diabetic retinopathy, right eye
    E11.3553Type 2 diabetes mellitus with proliferative diabetic retinopathy, left eye
    E11.3559Type 2 diabetes mellitus with proliferative diabetic retinopathy, bilateral/unspecified
    E11.3591Type 2 diabetes mellitus with proliferative diabetic retinopathy without macular edema, right eye
    E11.3592Type 2 diabetes mellitus with proliferative diabetic retinopathy without macular edema, left eye
    E11.3593Type 2 diabetes mellitus with proliferative diabetic retinopathy without macular edema, bilateral
    E11.3599Type 2 diabetes mellitus with proliferative diabetic retinopathy without macular edema, unspecified
    E11.36Type 2 diabetes mellitus with diabetic cataract
    E11.37X1Type 2 diabetes mellitus with diabetic macular edema, resolved following treatment, right eye
    E11.37X2Type 2 diabetes mellitus with diabetic macular edema, resolved following treatment, left eye
    1–10 of 54
    1/6
    FDA product codes and device listingsmixed
    SBA (product code)Eversense 365 CGM system (FDA product code listed in text)
    MDS, QCD, QHJ (product codes)CGM product codes referenced for FDA information
    LZG, QFG (product codes)CGM product codes referenced for FDA information
    OZP (product code)Automated insulin delivery/hybrid closed-loop insulin pumps product code referenced for FDA information
    Minimum CGM monitoring duration for CPT 95249/95250
    Minimum monitoring durationCPT 95249 and 95250 require ambulatory continuous glucose monitoring for a minimum of 72 hours
    Codes referenced95249 (patient-provided) and 95250 (physician/office-provided) both specify ≥72 hours of monitoring
    Associated reporting code95251 covers analysis, interpretation, and report for ambulatory CGM ≥72 hours
    HbA1c change reported in studies
    Reported HbA1c change (single-arm cohorts)Single-arm Eversense cohorts demonstrated approximately -0.4% to -0.5% reduction in HbA1c

    Provider Requirements and Authorization

    Prior Authorization

    State-specific prior authorization requirement (Nebraska DHHS references)

    For Nebraska members, prior authorization and medical necessity decisions for external insulin pumps must follow Nebraska DHHS clinical coverage criteria by referring to Nebraska Department of Health and Human Services, Code § 471-7-004.02(EE): Insulin Infusion Pumps, External. Similarly, CGM medical necessity criteria reference Nebraska DHHS Code § 471-7-004.02(Q).

    • Providers must use the Nebraska DHHS code sections noted when submitting prior authorization requests for external insulin pumps and CGMs.
    • Long-term CGM (>14 days) medical necessity criteria are governed by the Nebraska Heritage Health Plan advisory (see Health Plan Advisory 24-15).
    Prior Authorization

    Refer repair/replacement prior authorization to DME/Repairs policy

    Repair and replacement coverage for devices referenced in this policy is governed by UnitedHealthcare's Durable Medical Equipment, Orthotics, Medical Supplies, and Repairs/Replacements (for Nebraska Only) policy; prior authorization or benefit limits may apply under that policy.

    Key Definitions

    Adjunctive CGM — definition and implications
    DefinitionAdjunctive CGM: a CGM that requires the user to verify CGM-displayed glucose levels or trends with a blood glucose monitor before making treatment decisions
    Clinical implicationReadings from adjunctive CGMs are not used alone for treatment changes without confirmatory SMBG
    Regulatory sourcesDefinition cites CMS and ADA guidance as referenced in policy definitions
    Intermittently Scanned (Flash) CGM (isCGM) — definition
    DefinitionIntermittently Scanned (Flash) CGM (isCGM): devices with a combined sensor/transmitter and a separate reader that measure continuously but require scanning for visualization and storage of glucose values; available with or without alarms
    Use caseisCGM systems require the user to scan the sensor to view and store glucose data rather than continuous automatic display

    Background and Evidence Summary

    Continuous glucose monitoring (CGM) systems continuously measure interstitial glucose using a sensor, transmitter, and a display or receiver and are available in several classes. Real‑time CGM (rtCGM) systems provide continuous glucose readings and alerts for out‑of‑range values. Intermittently scanned (isCGM or flash) CGM requires scanning to visualize stored glucose data. Adjunctive CGMs require confirmation with a blood glucose meter before treatment decisions, whereas non‑adjunctive CGMs can be used to make treatment decisions without verification. CGMs may be provided as short‑term professional (clinic‑owned, typically 3–14 days) systems for diagnostic assessment or as personal wearable systems with disposable or implantable sensors for ongoing management.

    Policy Revision History

    2026-08-01policy_revisionLatest

    Revised state-specific instructions: clarified Nebraska DHHS Code § 471-7-004.02(EE) should be used for medical necessity clinical coverage criteria for external insulin infusion pumps (external).

    2026-08-01policy_revision

    Updated Nebraska DHHS Code reference § 471-7-004.02(Q) to specify it provides medical necessity clinical coverage criteria for continuous glucose monitors (CGMs).

    2026-08-01
    Policy Summary
    PayerUnitedHealthcare
    PolicyContinuous Glucose Monitoring and Insulin Delivery for Managing Diabetes (for Nebraska Only)
    Policy CodePolicy CS024NE.AD
    Change TypeState-referenced criteria updates and removal of long-term CGM criteria
    Effective DateAug 1, 2026
    Last ReviewAug 1, 2026
    Next Review DateN/A
    Key ActionRefer to Nebraska DHHS Code and Heritage Health Plan advisory for state-specific medical necessity criteria and prior authorization requirements.
    SourceLink
    On This Page
    Coverage Criteria and RationaleProcedure, HCPCS, and Diagnosis CodesProvider Requirements and AuthorizationKey DefinitionsBackground and Evidence SummaryPolicy Revision History
    Implantable CGM (Eversense) evidence: Evidence for implantable CGM systems (Eversense) includes cohort studies, randomized trials, and registries showing moderate accuracy, reductions in HbA1c in single-arm cohorts (~0.4–0.5%), and improvements in time-in-range; however, overall evidence quality is variable and clinical utility across outcomes remains uncertain.

    PROMISE, PRECISION, PRECISE II, PRECISE, ENHANCE, PMCF registry, Hayes assessment cited.

    Evidence context
    Hayes assessment and single-arm cohort studies suggest statistically significant HbA1c reductions of ~0.5% but clinical relevance is uncertain
    RCT findingsOne RCT reported no difference in HbA1c between activated vs blinded Eversense groups
    Time in range — reported values and thresholds
    Time in range thresholdTime in range defined as ≥70–180 mg/dL
    Observed Sanchez et al. valueSanchez et al. reported time in range of 62.3% in first U.S. commercial Eversense users
    Other reported glycemic distributionSanchez et al. also reported >180–250 mg/dL = 21.9%, >250 mg/dL = 11.6%, <70 mg/dL = 4.1%, <54 mg/dL = 1.2%
  1. Refer prior authorization and claims questions about repairs or replacements to the Durable Medical Equipment, Orthotics, Medical Supplies, and Repairs/Replacements (for Nebraska Only) policy.
  2. Prior Authorization

    Follow UHC policy plus Nebraska DHHS / Heritage Health Plan references

    When making medical necessity determinations and prior authorization decisions, follow UnitedHealthcare policy together with the referenced Nebraska DHHS code sections and Heritage Health Plan advisory as applicable.

    • Use Nebraska Department of Health and Human Services Code § 471-7-004.02(EE) for external insulin pumps and § 471-7-004.02(Q) for CGMs.
    • For long-term CGM (>14 days), refer to Heritage Health Plan: Health Plan Advisory 24-15 per the policy revision notes.
    Denial Risk

    Requests for devices listed as unproven may be denied

    Devices described in this policy as unproven (for example, nonprogrammable transdermal insulin delivery systems such as V-Go and implantable insulin pumps) are considered unproven/not medically necessary due to insufficient evidence; coverage may be denied if these devices are requested without supporting evidence.

    • Clinical reviewers may deny requests for devices listed as unproven or not medically necessary.
    • Provide robust clinical evidence if seeking coverage for these device types despite the policy designation.
    Denial Risk

    Nonprogrammable transdermal insulin delivery — limited evidence; expect additional documentation

    Nonprogrammable transdermal insulin delivery devices (e.g., V-Go) have limited and low-quality evidence; clinical reviewers may require additional documentation or may consider such devices not medically necessary.

    • Studies cited are observational or retrospective with limitations (no control groups, high attrition); larger well-designed trials are needed.
    • Expect requests to include prior therapy history and rationale for why alternative, proven therapies are not suitable.
    Step Therapy

    Step therapy — no specific step requirements in this policy

    No specific step therapy requirements are specified in this policy for CGMs or insulin delivery devices.

    • Clinical reviewers may still request documentation of prior therapies when evaluating requests for unproven devices.
    Documentation Required

    Maintain complete medical record documentation to support medical necessity

    The patient's medical record must contain documentation that fully supports medical necessity, including relevant history, physical examination, and results of pertinent diagnostic tests or procedures; records must be legible and made available upon request.

    • Include prior treatment history, reasons for device selection, and objective data showing medical need.
    • Ensure documentation is maintained in the medical record and produced when requested for review.
    Documentation Required

    Use specified ICD-10 diagnosis codes for documentation

    Use the extensive ICD-10 diagnosis codes listed in the policy to support medical necessity documentation when submitting prior authorization requests or claims.

    • Select the most specific diabetes- or complication-related ICD-10 code(s) from the policy's applicable codes to document the clinical indication.
    Documentation Required

    Reference federal/state/contractual requirements and document the governing authority

    When applying coverage rules, reference and document any applicable federal, state (Nebraska), or contractual benefit terms; in the event of conflict, federal, state, or contractual requirements govern and may supersede this policy.

    • Document which federal, state, or contractual requirement was used to determine coverage for the member.
    • Nebraska DHHS codes and Heritage Health Plan advisory must be used where specified.
    Note
    Denial Risk

    Higher-priority federal/state/contractual rules govern coverage decisions

    Coverage decisions, including denials, must conform to higher-priority federal, state, or contractual requirements; failure to follow applicable statutes, regulations, or contract terms may lead to denial or override of this policy's guidance.

    • If a conflict exists between this policy and applicable federal/state/contractual requirements, the latter govern coverage determinations.
    Denial Risk

    Implantable insulin pumps and nonprogrammable devices — generally not covered

    Because implantable insulin pumps are only available in clinical trial settings and nonprogrammable transdermal devices are considered unproven, requests for these devices will generally be considered not medically necessary and may be denied.

    • Implantable insulin pumps: not commercially available; coverage not supported outside trials.
    • Nonprogrammable transdermal devices: insufficient evidence to establish safety and efficacy.
    Device typesisCGM may be offered for long-term personal use as described in the CGM device overview
    Non-Adjunctive CGM — definition
    DefinitionNon-Adjunctive CGM: a CGM that can be used to make treatment decisions without confirmation by a standalone blood glucose monitor
    Clinical implicationNon-adjunctive systems may be used alone for diabetes treatment decisions (no confirmatory SMBG required)
    Examples / regulatory notePolicy distinguishes non-adjunctive device coding (e.g., A4239, E2103) and lists nonadjunctive CGMs among available CGM models
    Professional CGM — clinic-placed short-term devices definition
    DefinitionProfessional CGM: clinic-placed devices worn for a discrete period (generally 7–14 days) that are clinic-owned and may provide blinded or visible data used to assess glycemic patterns and trends
    Typical durationGenerally used for 7–14 day monitoring periods for diagnostic assessment
    OwnershipProfessional CGM devices are clinic-owned rather than owned by the patient
    Real-Time CGM (rtCGM) — systems with alerts and real-time display
    DefinitionReal-Time CGM (rtCGM): systems with a sensor, transmitter, and receiver/smartphone that display continuous glucose readings in real time and provide audible alerts for out-of-range values
    FunctionalityrtCGM systems continuously display glucose and generate alerts; some systems require user calibration
    Use caseDesigned for long-term personal use allowing individuals to take action based on displayed data
    Hypoglycemia levels — Level 2 and Level 3 definitions
    Hypoglycemia Level 2Level 2 hypoglycemia: glucose <54 mg/dL (3.0 mmol/L); associated with increased risk for cognitive dysfunction and mortality
    Hypoglycemia Level 3Level 3 hypoglycemia: a severe event with altered mental and/or physical state requiring third-party assistance; life-threatening and requires emergent treatment
    SourceDefinitions cited from ADA (2025) and supporting references in the policy
    Continuous Glucose Monitor (CGM) — overall device class definition
    DefinitionContinuous Glucose Monitor (CGM): devices that continuously monitor interstitial glucose levels and include a sensor, transmitter, and receiver; available as short-term professional devices or long-term personal systems (rtCGM and isCGM) with disposable or implantable sensors
    Sensor typesAvailable sensors may be disposable (transcutaneous) or implantable (e.g., Eversense) with smart transmitter and mobile application
    Clinical rolesCGMs support ongoing glycemic assessment, time-in-range metrics, and may be used for treatment decisions depending on device labeling
    Insulin delivery systems — includes external pumps, patch pumps, and nonprogrammable transdermal devices
    DefinitionInsulin delivery systems include standard external insulin pumps (with tubing and infusion sets), patch pumps (e.g., OmniPod), and preset nonprogrammable transdermal devices (e.g., V-Go) as well as implantable pumps (currently only in clinical trials)
    Device examplesExamples listed include conventional programmable pumps and patch devices; nonprogrammable transdermal devices lack programmability
    Coverage noteNonprogrammable transdermal devices and implantable insulin pumps are described as unproven or limited to clinical trial settings in the policy
    Implantable CGM — definition and example (Eversense)
    DefinitionImplantable CGM: a glucose sensor implanted subcutaneously that provides continuous glucose measurements for an extended period (examples include the Eversense systems)
    Sensor longevityImplantable sensors are available with intended lives such as 90, 180, or up to 365 days (Eversense 365 cleared for up to 1 year)
    ComponentsImplantable CGM systems include an implanted sensor, a smart transmitter, and a mobile application to transmit readings
    Implantable insulin pump — definition and FDA approval note
    DefinitionImplantable insulin pump: an insulin delivery device placed internally to deliver insulin (controlled remotely); the policy notes that no implantable insulin pumps have received FDA approval at this time
    Regulatory statusImplantable insulin pumps are only available in clinical trial settings and are not FDA-approved for general use
    Coverage implicationBecause no FDA-approved implantable insulin pumps exist, they are considered investigational/not covered outside clinical trials per the policy
    policy_revision

    Removed prior long-term CGM (>14 days) coverage criteria and replaced them with instruction to refer to Nebraska DHHS Heritage Health Plan: Health Plan Advisory 24-15 for medical necessity criteria for long-term CGM (>14 days).

    2026-08-01supporting_information_update

    Updated Clinical Evidence and References sections to reflect the most current information and archived previous policy version CS024NE.AC.