Loading...

    Explore
    • Policy Monitoring
    • Live Policy Feed
    • Billing Codes
    • NPI Medicare & Medicaid
    • Healthcare Providers
    • Health Insurance Payers
    • States
    • Service Lines
    • Taxonomy Codes
    Lookup tools
    • Billing Code Lookup
    • CPT Modifier Lookup
    • Provider Taxonomy Code Lookup
    • Healthcare Provider & Facility Lookup
    • Health Insurance Payer Lookup
    • Payer Contact Directory

    Policy & Benchmark Tools

    • Prior Authorization Lookup
    • Coverage Criteria Lookup
    • Timely Filing Lookup
    • Billing Code Reimbursement Rates
    • Payer Comparison Dashboard
    • Facility Comparison Dashboard
    • All tools

    Company

    • About OpenPayer
    • Data Sources
    • Trek Health
    OpenPayerby Trek Health
    LinkedInYouTube

    © 2026 Trek Health. All rights reserved.

    OpenPayer is built and maintained by Trek Health.

    v1.0.28
    OpenPayerPolicy UpdatesEndocrinologyUnitedHealthcare CGM Insulin Delivery Coverage Upd…
    Ask Trek AI about this page

    OpenPayer is powered by Trek Health's payer performance platform. Trek continuously ingests, validates, and normalizes Transparency in Coverage data alongside payer policies and other commercial payer data to create a structured payer intelligence foundation. OpenPayer uses this foundation to deliver personalized search results, dynamically generated policy pages, and tailored policy monitoring based on each user's payers, specialties, billing codes, and areas of interest. The same intelligence powers broader payer performance workflows, including reimbursement benchmarking, contract evaluation, payer negotiations, and financial decision-making.

    ModifiedUnitedHealthcarePolicy CS024NM.F

    Continuous Glucose Monitoring and Insulin Delivery for Managing Diabetes (for New Mexico Only)

    Customize your policy alerts

    Sign up for UnitedHealthcare Policy CS024NM.F alerts

    Get alerted when Policy CS024NM.F changes without checking for updates manually.

    Monitor payer policy activity

    Receive email alerts as soon as relevant payer policies are published or updated.

    Defines UnitedHealthcare medical policy for continuous glucose monitoring (CGM) and insulin delivery devices and coverage criteria applicable to members in New Mexico.

    Policy Summary
    PayerUnitedHealthcare
    PolicyContinuous Glucose Monitoring and Insulin Delivery for Managing Diabetes (for New Mexico Only)
    Policy CodePolicy CS024NM.F
    Change TypeMaterial updates to insulin pump coverage and documentation language
    Effective DateAug 1, 2026
    Last ReviewAug 1, 2026
    Next Review Date
    Key ActionRequest prior authorization for long-term CGM or insulin delivery devices and provide legible medical records documenting history, exam, and relevant diagnostic tests to support medical necessity.
    SourceLink
    POLICY UPDATE CHANGES

    External continuous subcutaneous insulin infusion pumps (including Omnipod) are proven and medically necessary in certain circumstances when used according to FDA-labeled indications, contraindications, warnings, and precautions.

    External continuous subcutaneous insulin infusion pumps are medically necessary for managing individuals with diabetes due to causes other than type 1, type 2, or gestational diabetes that require intensive insulin therapy (insulin-treated at least three times a day).

    Medical records documentation language clarified: coverage is determined by federal, state, or contractual requirements and documentation may be required to assess clinical criteria but does not guarantee coverage.

    Updated Description of Services, Clinical Evidence, FDA, and References sections to reflect current information and archived previous policy version CS024NM.E.

    Up to 6 monthsInitial CGM auth
    Up to 12 monthsReauthorization
    Every 6 monthsProvider follow-up
    ≥18 yrsImplantable CGM age
    ≥3x/dayIntensive therapy
    08/01/2026Policy effective

    Coverage Criteria for CGM and Insulin Delivery

    Insulin delivery - External pumps (medically necessary)

    Insulin pumps (external) are covered when FDA-labeled indications and InterQual clinical criteria are met:

    External insulin infusion pumps: Device is used according to FDA-labeled indications, contraindications, warnings, and precautions and medical necessity clinical coverage criteria per InterQual are met.

    Includes individuals with diabetes due to causes other than type 1, type 2, or gestational diabetes who require intensive insulin therapy (insulin-treated at least three times a day).

    Insulin delivery - Unproven/not medically necessary

    Devices considered unproven and not medically necessary:

    Unproven insulin delivery devices: Nonprogrammable transdermal insulin delivery systems (e.g., V-Go) and implantable insulin pumps are unproven and not medically necessary due to insufficient evidence of efficacy.

    Implantable insulin pumps are currently available only in clinical trial settings.

    Non-implantable long-term CGM - Intensive therapy (covered with criteria)

    Non-implantable long-term CGM (greater than 14 days):

    Initial long-term CGM (intensive therapy): Device is used according to FDA labeling and InterQual clinical criteria are met for individuals requiring intensive insulin therapy (insulin-treated ≥3 times/day) or meeting other InterQual criteria.

    Refer to InterQual CP: Durable Medical Equipment, Continuous Glucose Monitors, Insulin Pumps, and Automated Insulin Delivery Technology for full clinical criteria.

    Continued long-term CGM (intensive therapy): Device used per FDA labeling; InterQual criteria met; individual is assessed by a provider every 6 months for adherence to the prescribed CGM regimen and treatment plan.assessment every 6 months

    Initial authorization up to 6 months; reauthorization up to 12 months.

    Non-Intensive therapy CGM - Covered for hypoglycemia indications

    Long-term CGM for non-intensive therapy:

    Initial long-term CGM (non-intensive therapy): Individual on non-intensive treatment (e.g., basal insulin and/or oral medications) with history of a level 3 hypoglycemic event OR recurrent (more than one) level 2 hypoglycemic events that persist despite multiple (more than one) attempts to adjust medication(s) and/or modify the diabetes treatment plan.
    Continued long-term CGM (non-intensive therapy): Initial clinical criteria for non-intensive therapy were met at initiation of CGM; individual is assessed by a provider every 6 months for adherence to the prescribed CGM regimen and treatment plan.assessment every 6 months

    Long-term CGM is unproven and not medically necessary for other non-intensive therapy indications.

    Implantable CGM - Covered with criteria

    Implantable CGM (e.g., Eversense):

    Initial implantable CGM: Device is used according to FDA labeling; age ≥ 18 years; and one of the following: requires intensive insulin therapy (insulin-treated at least three times a day or insulin pump) OR has a history of a level 3 hypoglycemic event or recurrent (more than one) level 2 hypoglycemic events that persist despite multiple (more than one) attempts to adjust medication(s) and/or modify the diabetes treatment plan.age ≥ 18

    Refer to InterQual CP for further clinical details.

    Continued implantable CGM: Individual continues to require intensive insulin therapy or met the initial hypoglycemia-based criteria at initiation; individual is assessed by a provider every 6 months for adherence to the prescribed CGM regimen and treatment plan.assessment every 6 months

    Noninvasive CGM - Not medically necessary

    Noninvasive CGM:

    Noninvasive CGM: Use of noninvasive CGM devices is unproven and not medically necessary for managing individuals with diabetes due to insufficient evidence of efficacy.

    Clinical coverage considerations and evidence summaries

    Coverage considerations and clinical evidence summaries included in the policy inform medical necessity determinations for insulin pumps and CGMs in populations beyond type 1 and type 2 diabetes

    Insulin pumps for other diabetes types: Professional societies state insulin pumps may be considered for specific diabetes types (e.g., cystic fibrosis–related diabetes, posttransplant diabetes, postpancreatic surgery) when insulin deficiency requires multiple daily injections; evidence is limited.

    See citations: ADA 2026; McCall et al., 2023

    Implantable insulin pumps are currently available only in a clinical trial setting.

    Implantable pumps not standard of care

    Nonprogrammable transdermal insulin delivery: Insufficient evidence demonstrates the safety and efficacy of nonprogrammable wearable disposable insulin delivery devices (e.g., V-Go); larger, well-designed prospective studies with long-term follow-up and comparative effectiveness data are needed.

    Observational studies report HbA1c improvements but have limitations

    Evidence and clinical utility

    Evidence summary and clinical utility considerations from trials and assessments

    Evidence summary: Multiple prospective cohort studies and several randomized trials evaluate implantable Eversense CGM systems; reported accuracy (MARD) and trial outcomes vary, with some trials showing reduced hypoglycemia time and modest HbA1c improvements. Overall evidence quality is variable and limited by small sample sizes, study design limitations, and limited comparative outcome data, leaving clinical utility for health outcomes uncertain.

    Supported by PROMISE, PRECISION, PRECISE II, PRECISE, ENHANCE trials and HTA assessments.

    Insulin delivery coverage criteria (summary)

    Policy updates and coverage rationale highlights

    External CSII pump coverage: External continuous subcutaneous insulin infusion pumps (including Omnipod) are proven and medically necessary in certain circumstances when used according to FDA-labeled indications, contraindications, warnings, and precautions.

    Added language in 08/01/2026 revision

    Intensive insulin therapy indication: External continuous subcutaneous insulin infusion pumps are medically necessary for managing individuals with diabetes due to causes other than type 1, type 2, or gestational diabetes when the condition requires intensive insulin therapy (insulin-treated at least three times a day).insulin-treated >= 3 times/day

    Added language in 08/01/2026 revision

    The policy designates certain devices as unproven and not medically necessary when available evidence does not demonstrate safety or efficacy. Specifically, nonprogrammable transdermal insulin delivery systems (e.g., V‑Go), implantable insulin pumps, and noninvasive continuous glucose monitoring (CGM) devices are listed as not medically necessary for routine management of diabetes due to insufficient evidence of benefit.

    Implantable insulin pumps are currently limited to research settings and are only available in a clinical trial context at this time. The policy also notes that nonprogrammable transdermal insulin devices lack high‑quality comparative evidence; larger, prospective studies with long‑term follow‑up are needed before these devices are considered medically necessary.

    Continuous glucose monitoring systems that are sold over the counter (OTC) without a prescription are out of scope for this policy and are not supported through mail‑order durable medical equipment channels.

    Examples of CGM products that are obtainable without a prescription and therefore out of scope include consumer OTC models such as Dexcom Stelo, Abbott Lingo, and Abbott Libre Rio.

    Long‑term CGM for individuals who are not on intensive insulin regimens is covered only for specific hypoglycemia indications. The policy requires a history of a level 3 hypoglycemic event or recurrent (more than one) level 2 hypoglycemic events that persist despite multiple attempts to adjust therapy; otherwise, long‑term CGM for nonintensive therapy is considered unproven and not medically necessary.

    The policy states there is insufficient evidence to support routine use of nonprogrammable wearable disposable insulin delivery devices. Observational and small retrospective studies report some HbA1c improvements, but limitations (lack of controls, small samples, attrition) mean safety and comparative effectiveness remain unestablished.

    Reviewers noted a limited high‑quality comparative evidence base overall: many studies are single‑arm cohorts or small trials, and available randomized trials and health technology assessments report variable quality. Because of these limitations, consistent clinical benefit on health outcomes has not been conclusively established for several implantable or novel devices.

    Billing, HCPCS, CPT, and Diagnosis Codes

    CGM CPT and monitoring codesCPT
    0446TCreation of subcutaneous pocket with insertion of implantable interstitial glucose sensor, including system activation and patient training.
    0448TRemoval of implantable interstitial glucose sensor with creation of subcutaneous pocket at different anatomic site and insertion of new implantable sensor, including system activation.
    95249Ambulatory continuous glucose monitoring via subcutaneous sensor ≥72 hours; patient-provided equipment, includes placement, calibration, training, and printout.
    95250Ambulatory continuous glucose monitoring ≥72 hours; office-provided equipment, placement, calibration, training, removal, and printout.
    95251Ambulatory continuous glucose monitoring analysis, interpretation and report.
    HCPCS supplies and device codesHCPCS
    A4226Supplies for maintenance of insulin infusion pump with dosage rate adjustment using therapeutic continuous glucose sensing, per week.
    A4238Supply allowance for adjunctive, nonimplanted CGM, 1 month supply = 1 unit.
    A4239Supply allowance for nonadjunctive, nonimplanted CGM, 1 month supply = 1 unit.
    A9274External ambulatory insulin delivery system, disposable, each, includes all supplies and accessories.
    A9276Sensor; invasive, disposable, for interstitial CGM, one unit = 1 day supply.
    A9277Transmitter; external, for use with nondurable medical equipment interstitial CGM.
    A9278Receiver (monitor); external, for use with nondurable medical equipment interstitial CGM.
    E0784External ambulatory infusion pump, insulin.
    E0787External ambulatory infusion pump, insulin, dosage rate adjustment using therapeutic continuous glucose sensing.
    E2102Adjunctive, nonimplanted continuous glucose monitor (CGM) or receiver.
    1–10 of 13
    1/2
    Artificial pancreas and diagnosis codesmixed
    S1034Artificial pancreas device system (e.g., low glucose suspend [LGS] feature) including continuous glucose monitor, blood glucose device, insulin pump and computer algorithm.
    S1035Sensor; invasive, disposable, for use with artificial pancreas device system.
    S1036Transmitter; external, for use with artificial pancreas device system.
    S1037Receiver (monitor); external, for use with artificial pancreas device system.
    E11.00Type 2 diabetes mellitus with hyperosmolarity without nonketotic hyperglycemic-hyperosmolar coma (NKHHC).
    E11.01Type 2 diabetes mellitus with hyperosmolarity with coma.
    Covered HCPCS/S Codes (CGM and insulin delivery)HCPCSCovered
    A4226Supplies for maintenance of insulin infusion pump with dosage rate adjustment using therapeutic continuous glucose sensing, per week
    A4238Supply allowance for adjunctive, nonimplanted continuous glucose monitor (CGM), includes all supplies and accessories, 1 month supply = 1 unit of service
    A4239Supply allowance for nonadjunctive, nonimplanted continuous glucose monitor (CGM), includes all supplies and accessories, 1 month supply = 1 unit of service
    A9274External ambulatory insulin delivery system, disposable, each, includes all supplies and accessories
    A9276Sensor; invasive (e.g., subcutaneous), disposable, for use with nondurable medical equipment interstitial continuous glucose monitoring system (CGM), one unit = 1 day supply
    A9277Transmitter; external, for use with nondurable medical equipment interstitial continuous glucose monitoring system (CGM)
    A9278Receiver (monitor); external, for use with nondurable medical equipment interstitial continuous glucose monitoring system (CGM)
    E0784External ambulatory infusion pump, insulin
    E0787External ambulatory infusion pump, insulin, dosage rate adjustment using therapeutic continuous glucose sensing
    E2102Adjunctive, nonimplanted continuous glucose monitor (CGM) or receiver
    1–10 of 13
    1/2
    Covered S Codes (Artificial pancreas systems)HCPCSCovered
    S1034Artificial pancreas device system (e.g., low glucose suspend [LGS] feature) including continuous glucose monitor, blood glucose device, insulin pump and computer algorithm that communicates with all of the devices
    S1035Sensor; invasive (e.g., subcutaneous), disposable, for use with artificial pancreas device system
    S1036Transmitter; external, for use with artificial pancreas device system
    S1037Receiver (monitor); external, for use with artificial pancreas device system
    Applicable ICD-10 Diagnosis CodesICD-10
    E11.00Type 2 diabetes mellitus with hyperosmolarity without nonketotic hyperglycemic-hyperosmolar coma (NKHHC)
    E11.01Type 2 diabetes mellitus with hyperosmolarity with coma
    E11.10Type 2 diabetes mellitus with ketoacidosis without coma
    E11.11Type 2 diabetes mellitus with ketoacidosis with coma
    E11.21Type 2 diabetes mellitus with diabetic nephropathy
    E11.22Type 2 diabetes mellitus with diabetic chronic kidney disease
    E11.29Type 2 diabetes mellitus with other diabetic kidney complication
    E11.311Type 2 diabetes mellitus with unspecified diabetic retinopathy with macular edema
    E11.319Type 2 diabetes mellitus with unspecified diabetic retinopathy without macular edema
    E11.3211Type 2 diabetes mellitus with mild nonproliferative diabetic retinopathy with macular edema, right eye
    1–10 of 60
    1/6
    FDA product codes (informational)mixed
    LZG, QFGExternal insulin pumps (FDA website reference)
    OZPAutomated insulin delivery systems / hybrid closed-loop pumps (FDA website reference)
    MDS, QCD, QHJCGMs (FDA website reference)
    FDA product codesmixed
    MDS, QCD, QHJFDA product codes referenced for CGM PMA/510(k) lookup
    SBAEversense 365 CGM system product code referenced in FDA 510(k) clearance information
    Age for implantable CGM — Age threshold for implantable CGM
    Age thresholdAge ≥ 18 years
    Population noteApplies to implantable CGM systems (e.g., Eversense) used per FDA labeling
    Clinical requirement optionsRequires either intensive insulin therapy (≥3 injections/day or insulin pump) OR history of level 3 hypoglycemia OR recurrent (>1) level 2 hypoglycemic events despite >1 treatment adjustments
    Hypoglycemia level 2 threshold — clinical threshold for level 2 hypoglycemia
    Level 2 hypoglycemia definition

    Prior Authorization, Documentation, and Provider Responsibilities

    Prior Authorization

    Prior authorization required; initial and continued durations specified

    Initial and continued requests for long-term CGM and insulin delivery devices are reviewed against the InterQual CP criteria; initial long-term CGM authorization will be for up to 6 months and reauthorization up to 12 months. For continued long-term use, the device must be used per FDA labeling, meet InterQual clinical criteria, and the individual must be assessed by a provider every 6 months for adherence to the prescribed CGM regimen and treatment plan.

    • Initial CGM authorization: up to 6 months
    • Reauthorization: up to 12 months
    • Provider assessment for continued use: every 6 months
    • Clinical review uses InterQual CP: Durable Medical Equipment, Continuous Glucose Monitors, Insulin Pumps, and Automated Insulin Delivery Technology
    Prior Authorization

    Prior authorization implied for listed device and DME codes

    Prior authorization is implied for the DME, CGM, and artificial pancreas HCPCS/S and CPT codes listed; providers should request authorization using the applicable HCPCS/S or CPT codes and supporting diagnosis codes to document medical necessity.

    Background and Rationale

    Continuous glucose monitoring systems provide continuous or near‑continuous interstitial glucose data via three components (sensor, transmitter, receiver) to guide diabetes management. CGMs may be short‑term (professional), real‑time, intermittently scanned (flash), disposable, or implantable; some systems integrate with insulin delivery to support automated or hybrid closed‑loop therapy.

    Definitions and Device Types

    Adjunctive Continuous Glucose Monitor
    DefinitionA CGM that requires verification with a blood glucose monitor prior to making treatment decisions.
    Guidance sourcesDefined per CMS and ADA references cited in policy
    Clinical implicationNot intended to be used alone for insulin dosing without confirmatory SMBG
    Nonadjunctive Continuous Glucose Monitor
    DefinitionA CGM that can be used to make treatment decisions without confirmatory blood glucose checks.
    Guidance sourcesDefined per CMS and ADA references cited in policy
    Clinical implication

    Policy Revision History

    2026-08-01policy_revisionLatest

    Added coverage rationale clarifying that external continuous subcutaneous insulin infusion (CSII) pumps (including Omnipod) are proven and medically necessary in certain circumstances when used per FDA labeling, and expanded indication to include individuals with diabetes due to causes other than type 1, type 2, or gestational diabetes who require intensive insulin therapy (insulin-treated ≥3 times/day).

    2026-08-01documentation_update

    Clarified medical records documentation expectations for reviews: coverage determined by federal, state, or contractual requirements; records may be required to assess clinical criteria but do not guarantee coverage; records must fully support medical necessity, be legible, and be made available upon request.

    Policy Summary
    PayerUnitedHealthcare
    PolicyContinuous Glucose Monitoring and Insulin Delivery for Managing Diabetes (for New Mexico Only)
    Policy CodePolicy CS024NM.F
    Change TypeMaterial updates to insulin pump coverage and documentation language
    Effective DateAug 1, 2026
    Last ReviewAug 1, 2026
    Next Review Date
    Key ActionRequest prior authorization for long-term CGM or insulin delivery devices and provide legible medical records documenting history, exam, and relevant diagnostic tests to support medical necessity.
    SourceLink
    On This Page
    Coverage Criteria for CGM and Insulin DeliveryBilling, HCPCS, CPT, and Diagnosis CodesPrior Authorization, Documentation, and Provider ResponsibilitiesBackground and RationaleDefinitions and Device TypesPolicy Revision History
    Implantable CGM (Eversense): Eversense implantable CGM systems have trial evidence reporting accuracy metrics and sensor longevity, but the overall body of evidence is of low to moderate quality with uncertainties in accuracy across glucose ranges and limited comparative outcome data.

    Hayes HTA 2022 (updated 2025) summarized evidence quality

    Glucose < 54 mg/dL (3.0 mmol/L)
    Clinical significanceAssociated with increased risk for cognitive dysfunction and mortality
    Related levelLevel 3: severe event requiring third-party assistance (life-threatening)
    Eversense sensor survival — 90% sensor survival at 365 days (ENHANCE)
    Sensor survival at 365 days90% sensor survival at 365 days (ENHANCE study)
    Study contextENHANCE was a prospective, multicenter, nonrandomized study of the Eversense 365 in 110 adults
    CalibrationStudy used primarily one calibration per week
    Eversense MARD — MARD 8.8% (ENHANCE)
    Reported MARDMean absolute relative difference (MARD) 8.8% (ENHANCE)
    Alert detection rates96.6% and 97.9% confirmed alert detection at 70 mg/dL and 180 mg/dL respectively
    SafetyNo serious adverse events related to device or insertion/removal procedures reported in ENHANCE
    Time in range (70-180 mg/dL) — 64.5% (Tweden et al. first cycle)
    Time in range (70–180 mg/dL)64.5% (Tweden et al., first sensor cycle aggregate)
    Equivalent minutes/dayApproximately 929 minutes per day in range during first cycle
    Other glycemic ranges (first cycle)<54 mg/dL: 1.1% (16 min); <70 mg/dL: 4.6% (66 min); >180–250 mg/dL: 22.8% (328 min); >250 mg/dL: 8.1% (117 min)
    • Submit applicable HCPCS/S or CPT codes (examples: A4226, A4238, A4239, A9274–A9278, E0784, E0787, E2102–E2103, S1030–S1037, 0446T/0448T, 95249–95251) when requesting authorization
    • Include relevant ICD-10 diagnosis codes (e.g., E11.x, O24.x) to support claims
    Note

    Coverage channel and scope — implantable/prescription CGMs in scope; OTC CGMs out of scope

    This policy applies to implantable and prescription CGM systems; continuous glucose monitoring systems available over the counter without a prescription are out of scope and are not supported by mail-order DME channels.

    • Implantable CGM systems (e.g., Eversense) and prescription nonimplantable CGMs are subject to this policy
    • OTC CGM products (examples: Dexcom Stelo, Abbott Lingo, Abbott Libre Rio) are out of scope and generally obtained through a local pharmacy rather than mail-order DME
    Prior Authorization

    Prior authorization and required documentation may be requested for pumps and implantable CGMs

    Policy updates clarify coverage criteria for external CSII pumps and implantable CGMs; prior authorization may be required per plan and documentation supporting medical necessity must be provided when requested.

    • External CSII pumps (including Omnipod) are medically necessary in certain circumstances when used according to FDA labeling and InterQual criteria
    • Documentation supporting medical necessity should be provided upon request and may affect authorization
    Step Therapy

    Nonprogrammable transdermal insulin devices (e.g., V-Go) — not medically necessary

    Nonprogrammable transdermal insulin delivery systems (for example, V-Go) are considered unproven and not medically necessary and are not appropriate substitutes for covered programmable insulin pumps.

    • Nonprogrammable wearable disposable devices lack sufficient evidence of safety and efficacy
    • These devices are categorized as unproven and not medically necessary in this policy
    Step Therapy

    Step considerations — document prior therapies/rationale for nonprogrammable transdermal devices

    Because evidence is limited for nonprogrammable transdermal insulin delivery devices, payers may require documentation of prior therapy trials or clinical rationale before considering coverage.

    • Documentation may include prior trial of programmable pumps or explanation why such trials are not appropriate
    • Limited evidence and study design weaknesses are cited as reasons for requiring additional documentation
    Note

    FDA clearance is informational and not sole basis for coverage

    FDA clearance or approval is informational only; FDA approval alone is not a basis for coverage decisions and UnitedHealthcare evaluates evidence and benefit considerations when determining coverage.

    • Policy explicitly states FDA approval alone is not a basis for coverage
    • Coverage determinations use clinical evidence and benefit considerations in addition to regulatory status
    Note

    Use of external utilization management tools (e.g., InterQual)

    UnitedHealthcare may use third-party tools such as the InterQual criteria to assist in administering benefits; utilization management tools can influence step therapy and authorization decisions.

    • InterQual CP may be used to assess clinical criteria for DME, CGMs, pumps, and automated insulin delivery
    • Use of external tools can affect prior authorization and utilization management
    Documentation Required

    Document clinical history, exam, and test results to support medical necessity

    The patient's medical record must document relevant medical history, physical examination, and pertinent diagnostic test results that fully support the medical necessity for the requested services; records should be legible, maintained in the chart, and made available upon request.

    • Include relevant history, exam findings, and diagnostic test results that justify the device
    • Maintain legible documentation in the patient's medical record and provide it on request
    Billing Rule

    Required coding on claims — include listed HCPCS/S/CPT and ICD-10 codes

    Submit applicable HCPCS, S, and CPT codes and relevant ICD-10 diagnosis codes on claims to support coverage and payment; examples of device and supply codes are listed in the policy.

    • Examples include A4226, A4238, A4239, A9274–A9278, E0784, E0787, E2102–E2103, S1030–S1037, 0446T/0448T, 95249–95251
    • Include appropriate ICD-10 codes (e.g., E11.x, O24.x) to document the diagnosis
    Note

    OTC CGM products are out of scope and have distinct documentation/benefit handling

    Continuous glucose monitors available over the counter without a prescription are out of scope for this policy; OTC CGM products obtained through retail pharmacies are not supported by mail-order durable medical equipment providers and have distinct benefit considerations.

    • Examples of OTC CGMs: Dexcom Stelo, Abbott Lingo, Abbott Libre Rio
    • OTC devices should not be billed as mailed DME; benefit coverage differs from prescription devices
    Denial Risk

    Denial risk if medical records do not support medical necessity or are unavailable

    When medical records do not fully support medical necessity or are not made available upon request, coverage may be denied in accordance with federal, state, or contractual benefit plan requirements.

    • Coverage determinations are governed by federal, state, or contractual plan requirements; conflicts are resolved in favor of those requirements
    • Failure to provide supporting medical records may result in denial
    Denial Risk

    Denial risk — long-term CGM for nonintensive therapy without specified hypoglycemia history

    Requests for long-term CGM for individuals on nonintensive therapy without the required history of a level 3 hypoglycemic event or recurrent level 2 hypoglycemic events that persisted despite multiple treatment adjustments are considered unproven and not medically necessary and may be denied.

    • Initial non-intensive therapy CGM requires history of level 3 hypoglycemia OR recurrent (>1) level 2 hypoglycemia despite >1 attempts to adjust medications/treatment
    • Long-term CGM for other nonintensive therapy indications is unproven and not medically necessary
    Billing Rule

    Repair and replacement coverage — follow the DME/Repairs & Replacements policy

    Refer to the Durable Medical Equipment, Orthotics, Medical Supplies, and Repairs/Replacements medical policy for details on repair and replacement coverage; failure to follow that policy could affect coverage of repairs or replacements.

    • Repair and replacement provisions are governed by the referenced DME/Repairs policy
    • Providers should consult that policy when requesting replacements or repairs to ensure coverage
    Denial Risk

    OTC CGMs out of scope — do not bill OTC products as mailed DME

    CGM systems that are available over the counter without a prescription are out of scope for this policy and are not supported by mail-order durable medical equipment providers; billing OTC CGMs as mailed DME may lead to denial.

    • OTC CGMs are typically obtained through local pharmacies and are excluded from mail-order DME channels
    • Coverage and billing for OTC devices differ from prescription CGM systems
    Note

    Benefit rule precedence — federal/state/contractual requirements govern

    Coverage is subject to federal, state, or contractual benefit plan requirements; in the event of a conflict those requirements govern — providers must check applicable benefit plan terms before relying on this policy.

    • Verify federal, state, or contractual plan requirements prior to requesting services
    • This policy is informational and does not replace plan-specific coverage mandates
    Note
    Permits insulin dosing decisions based on CGM readings alone when indicated
    Intermittently Scanned (Flash) CGM
    DefinitionDevices with a combined sensor/transmitter and a separate reader that require scanning to visualize and store glucose values; available with or without alarms.
    ComponentsSensor/transmitter plus reader; measures continuously but data are accessed by scanning
    Use caseDesigned for long-term personal use but requires user scanning for real-time visualization
    Professional CGM
    DefinitionClinic‑owned CGM devices placed for a discrete period (generally 7–14 days) to assess glycemic patterns; data may be blinded or visible.
    Typical useUsed for short-term diagnostic assessment rather than continuous home monitoring
    OwnershipDevices are owned by the clinic, not the patient
    Real-Time CGM
    DefinitionSystems with a sensor, transmitter, and receiver/smartphone that display glucose readings in real time and provide alerts.
    ComponentsSensor (subcutaneous), transmitter, and receiver/smartphone display
    FunctionMeasures and displays glucose continuously with audible/visual out‑of‑range alerts; some systems require user calibration
    Hypoglycemia level 2
    DefinitionGlucose < 54 mg/dL (3.0 mmol/L).
    Clinical significanceAssociated with increased risk for cognitive dysfunction and mortality
    Role in coverageUsed to define recurrent events that may qualify individuals for CGM coverage
    Hypoglycemia level 3
    DefinitionA severe event characterized by an altered mental and/or physical state requiring third‑party assistance for treatment.
    Clinical significanceLife‑threatening and requires emergent treatment
    Role in coverageA history of level 3 hypoglycemia can qualify individuals on non‑intensive therapy for long‑term CGM coverage
    CGM components and types
    ComponentsSensor, transmitter, and receiver (or smartphone) are the three CGM components.
    Device typesIncludes short‑term professional CGM, real‑time CGM, intermittently scanned (flash) CGM, disposable and implantable sensors, and systems integrated with insulin pumps.
    Sensor optionsAvailable sensors may be disposable or implantable (e.g., Eversense uses implantable fluorescence sensor)
    Insulin delivery systems
    External pumpsStandard external insulin pumps deliver basal and bolus insulin via tubing and subcutaneous infusion.
    Patch devicesPatch devices (e.g., V‑Go) deliver preset basal and on‑demand boluses transdermally and lack programmability.
    Implantable pumpsImplantable insulin pumps exist but are currently available only in clinical trial settings.
    Eversense 365
    Device identitySenseonics Eversense 365 implantable CGM system
    Indication/durationIndicated for continual glucose measurement for up to 1 year in individuals 18 years or older (FDA 510(k) clearance)
    Replacement of SMBGCleared for use to replace finger‑stick blood glucose measurements for diabetes treatment decisions
    MARD
    DefinitionMean absolute relative difference — a measure of CGM accuracy compared with reference glucose values.
    Use in trialsReported as a primary accuracy metric (e.g., MARD values in Tweden et al. and ENHANCE) to compare sensor performance against SMBG/reference methods.
    InterpretationLower MARD indicates closer agreement with reference glucose values
    Eversense 365 (implantable CGM details)
    Device identitySenseonics Eversense 365 implantable CGM system (implantable sensor with smart transmitter and mobile app)
    FDA clearance510(k) clearance for up to 1 year continuous use in adults (18+); can replace finger‑stick testing for treatment decisions
    Study supportENHANCE and other trials provided accuracy and sensor survival data informing device labeling and policy consideration
    Over-the-counter CGMs
    DefinitionCGM systems obtainable without a prescription (examples: Dexcom Stelo, Abbott Lingo, Abbott Libre Rio) that are out of scope for this policy.
    Acquisition channelObtained through local pharmacies and not supported by mail‑order DME providers per policy
    Coverage implicationOTC CGMs are excluded from this policy's coverage and prior authorization processes
    2026-08-01supporting_information_update

    Updated Description of Services, Clinical Evidence, FDA, and References sections and archived previous policy version CS024NM.E.