Loading...

    Explore
    • Policy Monitoring
    • Live Policy Feed
    • Billing Codes
    • Healthcare Providers
    • Health Insurance Payers
    • States
    • Service Lines
    • Taxonomy Codes
    Lookup tools
    • Billing Code Lookup
    • CPT Modifier Lookup
    • Provider Taxonomy Code Lookup
    • Healthcare Provider & Facility Lookup
    • Health Insurance Payer Lookup
    • Payer Contact Directory

    Policy & Benchmark Tools

    • Prior Authorization Lookup
    • Coverage Criteria Lookup
    • Timely Filing Lookup
    • Billing Code Reimbursement Rates
    • Payer Comparison Dashboard
    • Facility Comparison Dashboard
    • All tools

    Company

    • About OpenPayer
    • Data Sources
    • Request a Policy / Feedback
    • Trek Health
    OpenPayerby Trek Health
    LinkedInYouTube

    © 2026 Trek Health. All rights reserved.

    OpenPayer is built and maintained by Trek Health.

    v1.0.32
    OpenPayerPolicy UpdatesPain ManagementSummaCare Motor Cortex Stimulation Coverage | Open…
    Ask Trek AI about this page
    CurrentSummaCarePolicy N/A

    Motor Cortex Stimulation Policy

    Customize your policy alerts

    Sign up for all summacare policy alerts

    Know when summacare releases new policies or updates existing guidance.

    Monitor payer policy activity

    Receive email alerts as soon as relevant payer policies are published or updated.

    This policy governs coverage and medical-necessity determinations for motor cortex stimulation, including implantation, neurostimulator placement, mapping, and device analysis services. It applies to SummaCare commercial and Medicare members and considers the service experimental and investigational for all indications.

    Policy Summary
    PayerSummaCare
    PolicyMotor Cortex Stimulation Policy
    Policy CodePolicy N/A
    Change TypeNo material change
    Effective DateOct 8, 2026
    Last ReviewOct 8, 2026
    Next Review DateN/A
    Key ActionSubmit motor cortex stimulation for medical-necessity review; the service is considered experimental and investigational for all indications.
    SourceLink
    POLICY UPDATE CHANGES

    No material clinical or coverage changes in this revision.

    All indicationsMotor cortex stimulation coverage status
    8CPT codes listed as not covered
    0

    OpenPayer is powered by Trek Health's payer performance platform. Trek continuously ingests, validates, and normalizes Transparency in Coverage data alongside payer policies and other commercial payer data to create a structured payer intelligence foundation. OpenPayer uses this foundation to deliver personalized search results, dynamically generated policy pages, and tailored policy monitoring based on each user's payers, specialties, billing codes, and areas of interest. The same intelligence powers broader payer performance workflows, including reimbursement benchmarking, contract evaluation, payer negotiations, and financial decision-making.

    FDA-approved devices
    50%Pain-reduction threshold
    Commercial and MedicareLines of business

    Coverage Criteria

    All indications

    Motor cortex stimulation is considered experimental and investigational for any indication and all lines of business.

    Experimental and investigational status: Motor cortex stimulation is considered experimental and investigational for any indication because its effectiveness has not been established.

    Applies to SummaCare commercial and Medicare members.

    Motor cortex stimulation is excluded from coverage for any indication. The service is considered experimental and investigational because there are currently no FDA-approved devices for motor cortex stimulation and insufficient published peer-reviewed evidence supports its safety and efficacy.

    Coding Information

    CPT Codes NOT CoveredCPTNot Covered
    61850Twist drill or burr hole(s) for implantation of neurostimulator electrodes, cortical
    61860Craniectomy or craniotomy for implantation of neurostimulator electrodes, cerebral, cortical
    61885Insertion or replacement of cranial neurostimulator pulse generator or receiver, direct or inductive coupling; with connection to a single electrode array
    61886with connection to two or more electrode arrays
    64568Incision for implantation of cranial nerve (eg, vagus nerve) neurostimulator electrode array and pulse generator
    95961Functional cortical and subcortical mapping by stimulation and/or recording of electrodes on brain surface, or of depth electrodes, to provoke seizures or identify vital brain structures; initial hour of physician attendance
    95962each additional hour of physician attendance (List separately in addition to code for primary procedure)
    95970Electronic analysis of implanted neurostimulator pulse generator system (e.g., rate, pulse amplitude and duration, configuration of wave form, battery status, electrode selectability, output modulation, cycling, impedance and patient compliance measurements); simple or complex brain, spinal cord or peripheral (i.e., cranial nerve, peripheral nerve, sacral nerve, neuromuscular) neurostimulator pulse generator/transmitter, without reprogramming
    Successful temporary neurostimulator trial
    Success thresholdA temporary neurostimulator trial is successful when it reduces neuropathic pain by 50%.
    Trial sequenceThe procedure usually begins with a temporary neurostimulator.
    Permanent implantationA permanent neurostimulator may be implanted if the temporary trial successfully reduces neuropathic pain by 50%.

    Provider Actions

    Prior Authorization

    Coverage review required

    Obtain medical-necessity review for motor cortex stimulation. SummaCare considers the service experimental and investigational for commercial and Medicare members for any indication.

    Denial Risk

    Experimental and investigational service

    Motor cortex stimulation is considered experimental and investigational for any indication and all lines of business because its effectiveness, safety, and efficacy have not been established. Claims for motor cortex stimulation services are not covered.

    Background

    Motor cortex stimulation (MCS), also called cerebral cortex stimulation or extradural motor cortex stimulation (EMCS), involves placing electrodes over the primary motor cortex through a burr hole or small craniotomy. The electrodes are connected to an implantable, battery-powered neurostimulator. The procedure is primarily proposed for refractory neuropathic pain and may involve a temporary trial followed by permanent implantation when the trial produces a 50% reduction in neuropathic pain.

    Definitions

    Motor cortex stimulation (MCS)
    ProcedureMotor cortex stimulation (MCS) involves implantation of one or more electrodes over the primary motor cortex.
    Electrode placementThe electrodes are placed extradurally over the motor cortex through a burr hole or small craniotomy.
    Neurostimulator connectionThe electrodes are connected to an implantable, battery-powered neurostimulator.
    Cerebral cortex stimulation / extradural motor cortex stimulation (EMCS)
    Alternative terminologyCerebral cortex stimulation and extradural motor cortex stimulation (EMCS) are alternative terms for motor cortex stimulation.
    Electrode placementThe procedure involves placing one or more electrodes extradurally over the motor cortex.

    Not Covered Services

    Motor cortex stimulation is not covered for any indication. Related noncovered services include cortical neurostimulator electrode implantation and associated cranial neurostimulator procedures, including the listed services for electrode implantation, pulse-generator insertion or replacement, cortical mapping, and implanted neurostimulator analysis.

    Policy Summary
    PayerSummaCare
    PolicyMotor Cortex Stimulation Policy
    Policy CodePolicy N/A
    Change TypeNo material change
    Effective DateOct 8, 2026
    Last ReviewOct 8, 2026
    Next Review DateN/A
    Key ActionSubmit motor cortex stimulation for medical-necessity review; the service is considered experimental and investigational for all indications.
    SourceLink
    On This Page
    Coverage CriteriaCoding InformationProvider ActionsBackgroundDefinitionsNot Covered Services
    Device connectionThe electrodes are connected to an implantable, battery-powered neurostimulator.