Artificial Urinary Sphincter
Implantation of an artificial urinary sphincter may be considered medically necessary when the patient meets either pathway A or pathway B.
ONE of the following pathways
Pathway A
Patient is six or more months post-prostatectomy with symptoms refractory to behavioral and pharmacological therapies.
Pathway B
Patient's symptoms limit activities of daily living.
Failure, intolerance, or contraindication to conservative management, including medication, physical therapy, bladder training, or similar treatment.
Initial Injectable Bulking Agents
FDA-approved treatment with injectable bulking agents (e.g., Coaptite, Durasphere, Bulkamid, or Macroplastique) may be considered medically necessary when ALL of the following criteria are met.
ALL of the following
Patient has urinary stress incontinence and symptoms that limit activities of daily living.
Failure of, or contraindication to, conservative medical management.
Acute urogenital tract inflammation or infection.
Fragile urethral mucosal lining, such as after radiation therapy or surgery to the bladder neck.
Repeat Injectable Bulking Agents
Up to four repeat treatments with FDA-approved injectable bulking agents may be considered medically necessary when ALL of the following criteria are met.
ALL of the following
Patient has recurrence of stress urinary incontinence.
Patient meets all criteria for initial treatment with injectable bulking agents.
Initial Posterior Tibial Nerve Stimulation
Posterior tibial nerve stimulation administered once weekly for up to 12 weeks may be considered medically necessary when ALL of the following criteria are met.
ALL of the following
Patient has urinary urge incontinence with symptoms that limit activities of daily living.
Failure of, or contraindication to, conservative medical management.
Patient has failed a trial of two different classes of medications, such as antimuscarinic/anticholinergics and beta-3 adrenoceptor agonists, unless contraindicated.
Additional Posterior Tibial Nerve Stimulation
Subsequent posterior tibial nerve stimulation treatments may be considered medically necessary when the continuation criterion is met.
ALL of the following
Documented improvement in symptoms, such as through a voiding diary.1 treatment every month for a maximum of 2 years
The 2-year period begins with initiation of posterior tibial nerve stimulation treatment.
Removal of Posterior Tibial Nerve Stimulation
Removal of a posterior tibial nerve stimulator may be considered medically necessary when BOTH conditions are met.
ALL of the following
The device has been thoroughly evaluated and found to be no longer functional.
The device was appropriately placed for medical necessity.
Sacral Nerve Stimulation Trial
A trial period of sacral nerve stimulation with a temporarily implanted lead may be considered medically necessary when ALL of the following criteria are met.
ALL of the following
Patient has urinary urge incontinence or nonobstructive urinary retention, with symptoms that limit activities of daily living.
Failure of, or contraindication to, conservative medical management or behavioral treatments, such as pelvic floor exercises or intermittent catheterizations for nonobstructive urinary retention.
Patient has failed a trial of two different classes of medications, such as antimuscarinic/anticholinergics and beta-3 adrenoceptor agonists, unless contraindicated.
Incontinence is not related to a spinal cord injury or progressive, systemic neurologic condition.
Permanent Sacral Nerve Stimulator Implantation
Permanent implantation of a sacral nerve stimulator may be considered medically necessary when the trial response requirement is met.
ALL of the following
The trial period demonstrates documented improvement in symptoms.>= 50% improvement
Improvement must be demonstrated over a minimum trial period of 48 hours, such as through a voiding diary.
Sacral Nerve Stimulation Device Removal or Replacement
Sacral nerve stimulation device removal or replacement may be considered medically necessary when BOTH conditions are met.
ALL of the following
The device has been thoroughly evaluated and found to be no longer functional.
The device was appropriately placed for medical necessity.
Treatments with Supportive Evidence
For urinary dysfunction patients with symptoms refractory to conservative treatment, the evidence is summarized as follows.
ALL of the following
Low-quality but consistent evidence supports the use of artificial urinary sphincters and injectable bulking agents. Several evidence-based clinical practice guidelines also recommend their use.
Clinical practice guidelines and recent systematic reviews indicate that posterior tibial nerve stimulation and sacral nerve stimulation may similarly improve symptoms.
Evidence does not support the efficacy of transurethral radiofrequency therapy, muscle training with vaginal cones, muscle training with pelvic floor electrical stimulation, or implanted adjustable continence therapies.
Systematic reviews evaluating these therapies note a lack of long-term evidence from high-quality trials and call for additional large, randomized studies with direct comparison to other urinary incontinence treatment options to establish safety and efficacy.
Implantable Tibial Nerve Stimulation
The 2024 AUA/SUFU guideline identified tibial nerve stimulation, including implantable tibial nerve stimulation, as an accepted minimally invasive treatment option for patients with overactive bladder who have had an inadequate response to or cannot tolerate behavioral or pharmacologic therapy.
ALL of the following
Guideline context supports tibial nerve stimulation, including implantable tibial nerve stimulation, for appropriately selected patients with overactive bladder.
The guideline does not specifically endorse eCoin; the recommendation is based largely on evidence supporting tibial nerve stimulation and neuromodulation more broadly rather than robust comparative evidence demonstrating the safety and effectiveness of the eCoin device itself.
Implanted Adjustable Continence Therapy, such as the ProAct Therapy System; implantable tibial nerve stimulators, such as the eCOIN Peripheral Neurostimulator System or Revi; percutaneously implanted posterior tibial nerve stimulation systems, such as the ZIDA Wearable Neuromodulation System; intraurethral valve-pumps, such as the InFlow Intraurethral Valve-Pump from Vesiflo, Inc.; pelvic floor electrical stimulation; transurethral radiofrequency therapy, including the Renessa Procedure; transcutaneous tibial nerve stimulators, such as the Vivally System; vaginal cones; external female catheters, such as the PureWick Urine Collection System; endovaginal cryogen-cooled, monopolar radiofrequency remodeling; the Flyte System Controller; and autologous muscle cell therapy.
Evidence does not support the efficacy of transurethral radiofrequency therapy, muscle training with vaginal cones, muscle training with pelvic floor electrical stimulation, or implanted adjustable continence therapies. Systematic reviews note a lack of long-term evidence from high-quality trials and call for additional large, randomized studies with direct comparison to other urinary incontinence treatment options to establish safety and efficacy.
If an unlisted code is submitted for a non-covered service addressed in this policy, it will be denied as not covered.
Services that do not meet the stated medical-necessity criteria for the applicable treatment are considered not medically necessary. This includes failure to meet the required clinical conditions, treatment-history requirements, response thresholds, continuation requirements, or device-status conditions described above.
The treatments listed as not medically necessary in this section, including excluded urinary incontinence treatments and treatments lacking supporting efficacy evidence, are not covered as medically necessary under this policy.