Loading...

    Explore
    • Policy Monitoring
    • Live Policy Feed
    • Billing Codes
    • Healthcare Providers
    • Health Insurance Payers
    • States
    • Service Lines
    • Taxonomy Codes
    Lookup tools
    • Billing Code Lookup
    • CPT Modifier Lookup
    • Provider Taxonomy Code Lookup
    • Healthcare Provider & Facility Lookup
    • Health Insurance Payer Lookup
    • Payer Contact Directory

    Policy & Benchmark Tools

    • Prior Authorization Lookup
    • Coverage Criteria Lookup
    • Timely Filing Lookup
    • Billing Code Reimbursement Rates
    • Payer Comparison Dashboard
    • Facility Comparison Dashboard
    • All tools

    Company

    • About OpenPayer
    • Data Sources
    • Request a Policy / Feedback
    • Trek Health
    OpenPayerby Trek Health
    LinkedInYouTube

    © 2026 Trek Health. All rights reserved.

    OpenPayer is built and maintained by Trek Health.

    v1.0.32
    OpenPayerPolicy UpdatesEndocrinologyJefferson Health Plans Insulin Pump Coverage | Ope…
    Ask Trek AI about this page
    ModifiedPartners Insurance Company dba Jefferson Health PlansPolicy MN.027.A

    External Infusion Pump, Insulin

    Customize your policy alerts

    Sign up for partners_insurance_company_dba_jefferson_health_plans Policy MN.027.A alerts

    Get alerted when Policy MN.027.A changes without checking for updates manually.

    Monitor payer policy activity

    Receive email alerts as soon as relevant payer policies are published or updated.

    Coverage policy for the medical necessity of external insulin infusion pumps, including initial therapy, continued use, and replacement, across applicable Jefferson Health Plans lines of business.

    Policy Summary
    PayerPartners Insurance Company dba Jefferson Health Plans
    PolicyExternal Infusion Pump, Insulin
    Policy CodePolicy MN.027.A
    Change TypeNew policy
    Effective Date11/03/2025
    Last ReviewSep 18, 2025
    Next Review DateN/A
    Key ActionSubmit comprehensive clinical documentation and relevant medical records demonstrating the member’s need for insulin pump therapy and ability to manage the device.
    SourceLink
    POLICY UPDATE CHANGES

    The policy establishes medical-necessity criteria for external insulin infusion pumps.

    The policy history identifies this as a new policy version.

    ≥4/dayRequired average glucose self-testing frequency unless using a CGM
    6 monthsMinimum duration of multiple daily insulin injections

    OpenPayer is powered by Trek Health's payer performance platform. Trek continuously ingests, validates, and normalizes Transparency in Coverage data alongside payer policies and other commercial payer data to create a structured payer intelligence foundation. OpenPayer uses this foundation to deliver personalized search results, dynamically generated policy pages, and tailored policy monitoring based on each user's payers, specialties, billing codes, and areas of interest. The same intelligence powers broader payer performance workflows, including reimbursement benchmarking, contract evaluation, payer negotiations, and financial decision-making.

    >7%Example HbA1c threshold supporting medical necessity
    6 monthsTreating-physician evaluation interval for continued coverage
    E0784HCPCS code for external ambulatory insulin infusion pump

    Medical Necessity and Coverage Criteria

    Initial Therapy

    Covered when ALL of the following criteria are met, including the applicable InterQual criteria.

    The member meets the applicable InterQual criteria for an external insulin infusion pump. InterQual criteria are available upon request; licensed users may access them through InterQual.

    InterQual criteria may be requested when needed.

    ALL of the following additional clinical criteria

    • The member has documented glucose self-testing averaging at least 4 times per day, or has used a continuous glucose monitor (CGM) for the past 2 months.
    • ONE of the following glycemic-control criteria

      • The member has an elevated glycosylated hemoglobin level, such as HbA1c greater than 7 percent, while receiving multiple daily insulin injections (at least 3 injections per day) for at least 6 months.
      • The member has a history of recurrent hypoglycemia while receiving multiple daily insulin injections, such as blood glucose levels less than 70 mg/dL.
      • The member has wide fluctuations in blood glucose before mealtime, such as pre-prandial blood glucose levels commonly exceeding 140 mg/dL, while receiving multiple daily insulin injections.
      • The member has dawn phenomenon with fasting blood sugars frequently exceeding 200 mg/dL while receiving multiple daily insulin injections.
      • The member has a history of severe glycemic excursions while receiving multiple daily insulin injections.
    • The member or caregiver has demonstrated the ability and commitment to comply with pump care, frequent blood glucose self-monitoring, and careful attention to diet and exercise; has completed diabetic education; and is comfortable with carbohydrate counting and diabetic meal planning.
    • The member or caregiver can manage the device technology.
    • The pump is ordered by, and follow-up care is managed by, qualified practitioners as appropriate under federal and state MA policy, including 42 CFR §440.70(a), with experience managing persons with insulin infusion pumps, such as an endocrinologist. The practitioner works closely with nurses, diabetic educators, and dieticians knowledgeable in insulin infusion pump use.

    Replacement Therapy

    Replacement of an external insulin infusion pump is medically necessary when ANY of the following conditions applies.

    ANY of the following

    • The member is a child who requires a larger insulin reservoir.
    • The pump is out of warranty, malfunctioning, and cannot be refurbished.
    • The Personal Diabetes Monitor (PDM) for an Omnipod System is out of warranty, malfunctioning, and cannot be refurbished.

    Continuation Therapy

    Continued medical necessity requires ALL of the following ongoing documentation and evaluation requirements.

    ALL of the following

    • The member is seen and evaluated by the treating physician at least once every 6 months.At least every 6 months
    • The benefits from insulin pump use are documented in the medical record, such as improved diabetes control or improved HbA1c.

    Replacement of a functioning insulin pump with an insulin pump that communicates wirelessly with a glucose monitor is not medically necessary, because wireless communication has not been shown to improve clinical outcomes.

    Services or items determined by the Plan to be investigational, experimental, cosmetic, or not medically necessary are excluded from coverage for all lines of business, subject to the member's applicable benefit documents and benefit contract.

    Replacing a functioning insulin pump solely with an insulin pump that provides wireless communication to a glucose monitor is not medically necessary.

    An extension of approval is not medically necessary when the member's condition does not show improvement and there is evidence of noncompliance.

    Coding and Clinical Qualification Details

    HCPCS CodeHCPCS
    E0784External ambulatory infusion pump, insulin
    Glucose self-testing
    Required frequencyAverage of at least 4 glucose self-tests per day
    Applies toDocumented glucose self-testing for external insulin pump qualification
    AlternativeUse of a continuous glucose monitor for the past 2 months
    CGM use
    Qualifying periodContinuous glucose monitor used for the past 2 months
    DocumentationDocument the member’s use of a CGM for the preceding 2 months
    Qualification pathway

    Provider Documentation and Review Requirements

    Prior Authorization

    Medical Necessity Review Required

    Before approval, establish that the external insulin infusion pump is medically necessary under the applicable InterQual® criteria and the additional clinical criteria in this policy. InterQual criteria may be available upon request; qualified practitioners must order the pump and manage follow-up care.

    • The treating practitioner should have experience managing insulin infusion pumps and work with knowledgeable nurses, diabetes educators, and dieticians.
    • The member or caregiver must be able to manage the device and demonstrate commitment to pump care, glucose monitoring, diet, exercise, diabetic education, carbohydrate counting, and meal planning.
    Documentation Required

    Submit Comprehensive Clinical Records

    Submit comprehensive clinical documentation supporting the member’s clinical need for insulin pump therapy and demonstrating proper patient selection. Records must show that the member meets the established clinical criteria and can appropriately manage insulin pump therapy.

    External Insulin Pump Overview

    An external insulin pump, also called a continuous subcutaneous insulin infusion system, is a battery-operated, computerized device that delivers programmed basal insulin continuously under the skin and allows the member to administer bolus doses. It provides an alternative to multiple daily insulin injections.

    Key Terms

    External insulin pump
    Device typeBattery-operated, computerized device
    FunctionDelivers insulin subcutaneously in a programmed and controlled manner
    Therapy providedContinuous insulin infusion instead of multiple daily insulin injections
    Continuous Glucose Monitor (CGM)
    PurposeContinually monitors blood glucose
    FeedbackProvides real-time blood glucose updates
    ConfigurationUses a device attached to the body
    Policy Summary
    PayerPartners Insurance Company dba Jefferson Health Plans
    PolicyExternal Infusion Pump, Insulin
    Policy CodePolicy MN.027.A
    Change TypeNew policy
    Effective Date11/03/2025
    Last ReviewSep 18, 2025
    Next Review DateN/A
    Key ActionSubmit comprehensive clinical documentation and relevant medical records demonstrating the member’s need for insulin pump therapy and ability to manage the device.
    SourceLink
    On This Page
    Medical Necessity and Coverage CriteriaCoding and Clinical Qualification DetailsProvider Documentation and Review RequirementsExternal Insulin Pump OverviewKey Terms
    CGM use may satisfy the glucose-monitoring criterion instead of testing an average of at least 4 times per day
    HbA1c
    Example elevated levelHbA1c greater than 7 percent
    Treatment contextElevated HbA1c while using multiple daily insulin injections
    DocumentationSubmit HbA1c results supporting the qualifying elevated level
    Multiple daily injections
    Minimum frequencyAt least 3 insulin injections per day
    Minimum durationAt least 6 months
    Qualification contextMultiple daily injections used when documenting an elevated HbA1c or qualifying glycemic complication
    Hypoglycemia
    ThresholdBlood glucose levels less than 70 mg/dL
    Clinical descriptionA blood glucose level low enough to cause symptoms and potentially harm
    Typical equivalentBelow 70 mg/dL (3.9 mmol/L)
    Pre-prandial glucose
    CriterionPre-prandial blood glucose levels commonly exceed 140 mg/dL
    Clinical patternWide fluctuations in blood glucose before mealtime
    Qualification contextA qualifying glycemic event while on multiple daily insulin injections
    Dawn phenomenon
    CriterionFasting blood sugars frequently exceed 200 mg/dL
    Associated conditionDawn phenomenon
    Qualification contextA qualifying glycemic event while on multiple daily insulin injections
    • Include relevant medical records and clinical history supporting the request.
    • Coverage of CGM-related components remains contingent on meeting all applicable CGM coverage criteria.
    Documentation Required

    Document Initial Clinical Qualification

    For an initial request, document the required glucose-monitoring history and qualifying clinical evidence while the member is receiving multiple daily insulin injections.

    • Document glucose self-testing at least 4 times daily on average, or CGM use for the preceding 2 months.
    • Document HbA1c greater than 7% while using at least 3 insulin injections daily for at least 6 months, or a qualifying condition: recurrent hypoglycemia below 70 mg/dL, wide pre-meal glucose fluctuations commonly exceeding 140 mg/dL, dawn phenomenon with fasting glucose frequently exceeding 200 mg/dL, or severe glycemic excursions.
    • Document the member’s or caregiver’s ability and commitment to comply with pump care, frequent glucose monitoring, diet and exercise requirements, diabetes education, carbohydrate counting, meal planning, and device technology management.
    Documentation Required

    Document Continued Benefit Every Six Months

    For continued coverage, document that the member is evaluated by the treating physician at least every 6 months and that insulin pump use continues to provide a clinical benefit.

    • Include documented benefit such as improved diabetes control or HbA1c.
    • If the condition has not improved and there is evidence of noncompliance, extension of approval is not considered medically necessary.
    Documentation Required

    Justify the Replacement Request

    A replacement external insulin infusion pump must be supported by documentation of an applicable covered replacement reason.

    • A child requires a larger insulin reservoir.
    • The pump is out of warranty, malfunctioning, and cannot be refurbished.
    • The Omnipod Personal Diabetes Monitor (PDM) is out of warranty, malfunctioning, and cannot be refurbished.
    • Do not request replacement of a functioning pump solely to obtain wireless communication with a glucose monitor; this is not medically necessary because improved clinical outcomes have not been demonstrated.
    Note

    Use Medicare LCD Guidance

    For Jefferson Health Plans Medicare variations, reference Medicare LCD L33794 for the applicable external insulin pump coverage guidelines.

    • Medicare LCD: https://www.cms.gov/medicare-coverage-database/view/lcd.aspx?LCDId=33794
    Denial Risk

    Initial Criteria Not Met: Denial Risk

    An initial request may be denied when the member does not meet InterQual medical-necessity requirements or the additional clinical criteria. Missing or inadequate evidence of glucose monitoring, qualifying glycemic history, treatment experience, self-management ability, or qualified practitioner involvement can prevent approval.

    • Failure to document glucose self-testing at least 4 times daily or CGM use for the preceding 2 months.
    • Failure to document the required HbA1c and multiple-daily-injection history, or an accepted qualifying glycemic condition.
    • Failure to demonstrate diabetes education, pump-care commitment, device-management ability, or appropriate clinical management.
    Denial Risk

    Insufficient Continued-Therapy Documentation

    Continued therapy may be denied when required follow-up and benefit documentation is missing or shows that pump therapy is not improving the member’s condition. Evidence of noncompliance also prevents an extension of approval as medically necessary.

    • No treating-physician evaluation documented at least every 6 months.
    • No documented benefit, such as improved diabetes control or HbA1c.
    • Documented lack of improvement or noncompliance.
    Denial Risk

    Replacement Conditions Not Met

    A replacement may be denied when the requested reason does not meet the policy’s covered replacement conditions or when the reason is not adequately documented.

    • The pump or Omnipod PDM is functioning, within warranty, or can be refurbished.
    • The request is for a larger reservoir without documentation that the member is a child who requires it.
    • The request replaces a functioning pump solely with a model offering wireless communication to a glucose monitor.
    Denial Risk

    Excluded Service Categories

    Investigational, experimental, cosmetic, and not-medically-necessary services or items are excluded from coverage for all lines of business, subject to the member’s applicable benefit contract and benefit limitations.

    • Medical policies assist with benefit administration and do not themselves describe the member’s benefits.
    • Coverage applies only when the requested service or item is an eligible benefit under the applicable benefit contract on the date rendered.
    Glycated hemoglobin (HbA1c)
    DefinitionA form of hemoglobin created when glucose irreversibly binds to hemoglobin
    Biologic contextGlucose binds to hemoglobin over the typical 120-day lifespan of a red blood cell
    Clinical useServes as an important marker for long-term glycemic control
    Hypoglycemia
    DefinitionA blood glucose level low enough to cause symptoms and potentially harm
    Typical thresholdBelow 70 mg/dL (3.9 mmol/L)
    Clinical significanceLow blood glucose that may produce symptoms and cause harm