Loading...

    Explore
    • Policy Monitoring
    • Live Policy Feed
    • Billing Codes
    • Healthcare Providers
    • Health Insurance Payers
    • States
    • Service Lines
    • Taxonomy Codes
    Lookup tools
    • Billing Code Lookup
    • CPT Modifier Lookup
    • Provider Taxonomy Code Lookup
    • Healthcare Provider & Facility Lookup
    • Health Insurance Payer Lookup
    • Payer Contact Directory

    Policy & Benchmark Tools

    • Prior Authorization Lookup
    • Coverage Criteria Lookup
    • Timely Filing Lookup
    • Billing Code Reimbursement Rates
    • Payer Comparison Dashboard
    • Facility Comparison Dashboard
    • All tools

    Company

    • About OpenPayer
    • Data Sources
    • Request a Policy / Feedback
    • Trek Health
    OpenPayerby Trek Health
    LinkedInYouTube

    © 2026 Trek Health. All rights reserved.

    OpenPayer is built and maintained by Trek Health.

    v1.0.32
    OpenPayerPolicy UpdatesDurable Medical Equipment (DME)Jefferson CGM Coverage Prior Auth | OpenPayer
    Ask Trek AI about this page
    CurrentJefferson Health PlansPolicy N/A

    Continuous Glucose Monitors

    Customize your policy alerts

    Sign up for all partners_insurance_company_dba_jefferson_health_plans policy alerts

    Know when partners_insurance_company_dba_jefferson_health_plans releases new policies or updates existing guidance.

    Monitor payer policy activity

    Receive email alerts as soon as relevant payer policies are published or updated.

    This policy governs coverage, prior authorization, medical necessity, equipment limits, and coding for continuous glucose monitors and related supplies across Jefferson Health Plans product lines, subject to product-specific requirements and the member’s benefit plan.

    Policy Summary
    PayerJefferson Health Plans
    PolicyContinuous Glucose Monitors
    Policy CodePolicy N/A
    Change TypeAnnual reviewreferences updated
    Effective DateN/A
    Last ReviewJul 15, 2026
    Next Review DateN/A
    Key ActionObtain prior authorization for rentals and DME costing more than $500.
    SourceLink
    POLICY UPDATE CHANGES

    The 2026 annual review updated the policy references.

    OpenPayer is powered by Trek Health's payer performance platform. Trek continuously ingests, validates, and normalizes Transparency in Coverage data alongside payer policies and other commercial payer data to create a structured payer intelligence foundation. OpenPayer uses this foundation to deliver personalized search results, dynamically generated policy pages, and tailored policy monitoring based on each user's payers, specialties, billing codes, and areas of interest. The same intelligence powers broader payer performance workflows, including reimbursement benchmarking, contract evaluation, payer negotiations, and financial decision-making.

    $500
    DME threshold requiring prior authorization
    6 monthsPre-order in-person evaluation
    30 unitsMonthly supply allowance
    3 yearsCGM receiver useful lifetime
    3 monthsTransmitter frequency

    Coverage Criteria

    Product-specific coverage

    Coverage varies by product line and member eligibility.

    Product-specific coverage pathway: For Medicaid and CHIP, follow the DHS Preferred Drug List and applicable SWPDL CGM policy requirements. For Medicare Advantage and Individual and Family Plans, cover CGMs when medically necessary under the DME benefit and the member's eligibility and benefit plan.

    Implantable CGM criteria

    An implantable interstitial glucose sensor is covered when ALL of the following are met.

    Implantable CGM medical necessity

    • The device is used for management of type 1 or type 2 diabetes mellitus.
    • Qualifying treatment program

      • The individual uses an insulin regimen that includes long-acting (basal) and rapid-acting (prandial/mealtime) insulin, or multiple daily injections of U500 insulin.
      • ALL of the following

        • The individual uses a continuous subcutaneous external insulin pump.

    CGM supplies integrated with an external pump

    Supplies for an adjunctive CGM integrated into an external insulin infusion pump are covered when ALL applicable criteria are met.

    Integrated pump CGM supplies: The beneficiary meets the CGM coverage criteria and the coverage criteria for an external insulin infusion pump.

    Investigational, experimental, cosmetic, and not medically necessary services or items are excluded from coverage for all lines of business, subject to the member’s applicable benefit contract.

    Investigational, experimental, cosmetic, or not medically necessary services or items are excluded from coverage for all lines of business.

    Services determined by the Plan to be not medically necessary are excluded from coverage.

    Services or items determined by the Plan to be not medically necessary are excluded from coverage.

    Coding and Billing Rules

    Therapeutic (Non-Adjunctive) Continuous Glucose MonitorsHCPCSCovered
    A4239Glucose monitor (CGM), includes all supplies and accessories, 1 month supply = 1 unit of service; non-adjunctive, non-implanted continuous glucose monitor or receiver
    Non-Therapeutic (Adjunctive) Continuous Glucose MonitorsHCPCSCovered
    A4238Supply allowance for adjunctive continuous glucose monitor (CGM), includes all supplies and accessories, 1 month supply = 1 unit of service
    E2102Adjunctive continuous glucose monitors or receiver
    A9276Sensor; invasive (e.g., subcutaneous), disposable, for use with interstitial continuous glucose monitoring system, 1 unit = 1-day supply
    A9277Transmitter; external, for use with interstitial continuous glucose monitoring system
    A9278Receiver (monitor); external, for use with interstitial continuous glucose monitoring system
    0446TCreation of subcutaneous pocket with insertion of implantable interstitial glucose sensor, including system activation and patient training
    0447TRemoval of implantable interstitial glucose sensor from subcutaneous pocket via incision
    0448TRemoval of implantable interstitial glucose sensor with creation of subcutaneous pocket at different anatomic site and insertion of new
    Non-therapeutic (adjunctive) continuous glucose monitorsmixed
    A4238Supply allowance for adjunctive continuous glucose monitor (CGM), includes all supplies and accessories, 1 month supply = 1 unit of service.
    E2102Adjunctive continuous glucose monitors or receiver.
    A9276Sensor; invasive (e.g., subcutaneous), disposable, for use with interstitial continuous glucose monitoring system, 1 unit = 1-day supply.
    A9277Transmitter; external, for use with interstitial continuous glucose monitoring system.
    A9278Receiver (monitor); external, for use with interstitial continuous glucose monitoring system.
    0446TCreation of subcutaneous pocket with insertion of implantable interstitial glucose sensor, including system activation and patient training.
    0447TRemoval of implantable interstitial glucose sensor from subcutaneous pocket via incision.
    0448TRemoval of implantable interstitial glucose sensor with creation of subcutaneous pocket at different anatomic site and insertion of new
    DME Prior Authorization Threshold
    Prior authorization thresholdDME costing over $500 requires prior authorization.
    Applies toDurable medical equipment requests.
    Related requirementPrior authorization is also required for DME rentals.
    Pre-Order Evaluation
    Required evaluationAn in-person visit between the treating practitioner and member is required.
    TimingThe visit must occur within six months before ordering the CGM.

    Provider Actions and Authorization

    Prior Authorization

    Prior Authorization for Non-Preferred Medicaid and CHIP CGMs

    For Medicaid and CHIP products, obtain prior authorization before requesting a non-preferred CGM. Coverage consideration may be given when the member requires the non-preferred device because of compatibility or operability with an insulin pump.

    • Applies to Medicaid and CHIP lines of business.
    • Preferred CGMs under the Pennsylvania DHS SWPDL include Dexcom G6/G7 and FreeStyle Libre 2/3.
    Prior Authorization

    Prior Authorization for Rentals and High-Cost DME

    Prior authorization is required for rentals and durable medical equipment (DME) costing more than $500.

    • Apply current accepted standards of care, applicable NCD/LCD guidance, or InterQual® when evaluating medical necessity.

    Unsupported block type: billing_rule

    Unsupported block type: documentation

    Unsupported block type: documentation

    Unsupported block type: documentation

    Continuous Glucose Monitor Overview

    Continuous glucose monitors measure interstitial glucose and may be used as adjunctive systems with self-monitoring blood glucose, as non-adjunctive systems requiring calibration, as factory-calibrated integrated systems, or as flash-monitor systems. Covered CGM systems support management of type 1 or type 2 diabetes when medically necessary and when the member meets applicable treatment and benefit requirements. An implantable interstitial glucose sensor is covered for members using an intensive insulin regimen or a continuous subcutaneous external insulin pump.

    CGM Definitions

    Adjunctive CGM
    DefinitionA CGM used together with a self-monitoring blood glucose device.
    Blood glucose deviceThe CGM is used with a self-monitoring blood glucose device.
    Use relationshipThe CGM is adjunctive to self-monitoring blood glucose.
    Non-Adjunctive CGM With Daily Calibration
    DefinitionA CGM that requires a daily self-monitoring blood glucose device for calibration.
    Calibration methodCalibration uses a self-monitoring blood glucose device.
    Calibration frequency

    Medical Necessity Criteria

    Implantable sensor treatment criteria

    An implantable interstitial glucose sensor is covered for diabetes management when the member uses one of the specified insulin treatment programs.

    Qualifying diabetes treatment: The individual uses an insulin regimen including long-acting basal and rapid-acting prandial/mealtime insulin, or multiple daily injections of U500 insulin; OR uses a continuous subcutaneous external insulin pump.

    Applies to management of type 1 or type 2 diabetes mellitus.

    Rental and Purchase Rules

    EquipmentRental and purchase rule
    Continuous glucose monitors and related DMEPrior authorization is required for rentals and DME costing more than $500.

    Replacement and Component Limits

    CGM Receiver Replacement
    EquipmentCGM receiver.
    Reasonable useful lifetimeThree years.
    Replacement documentationReplacement or renewal requires documentation that the current receiver is no longer usable under the applicable replacement requirements.
    CGM Transmitter Replacement
    EquipmentCGM transmitter.
    Replacement frequencyOnce every three months.
    Unit allowanceOne unit per three months when the CGM is covered.

    Required Documentation

    Documentation Required

    Document diabetes control and device appropriateness

    Before ordering a CGM, ensure the treating practitioner has an in-person visit with the member within six months before the order to evaluate diabetes control and determine whether the device is appropriate.

    Documentation Required

    Document replacement eligibility

    For replacement or renewal, document that the current CGM or component is malfunctioning, no longer under warranty, and cannot be repaired.

    Documentation Required

    Document continued clinical benefit

    For replacement or renewal, include a healthcare-provider evaluation from within the preceding six months and supporting record data demonstrating how the member benefits from continued CGM use.

    Excluded Services and Items

    The following are not covered: investigational or experimental services or items; cosmetic services or items; services or items determined by the Plan to be not medically necessary; and services or items that are not eligible under the member’s applicable benefit contract. Coverage is also subject to applicable benefit limits and exclusions.

    Policy Summary
    PayerJefferson Health Plans
    PolicyContinuous Glucose Monitors
    Policy CodePolicy N/A
    Change TypeAnnual reviewreferences updated
    Effective DateN/A
    Last ReviewJul 15, 2026
    Next Review DateN/A
    Key ActionObtain prior authorization for rentals and DME costing more than $500.
    SourceLink
    On This Page
    Coverage CriteriaCoding and Billing RulesProvider Actions and AuthorizationContinuous Glucose Monitor OverviewCGM DefinitionsMedical Necessity CriteriaRental and Purchase RulesReplacement and Component LimitsRequired DocumentationExcluded Services and Items
    PurposeThe visit evaluates diabetes control and determines device appropriateness.
    Supply Allowance
    Monthly allowance30 units of supplies.
    Six-month allowance180 units of supplies.
    Billing methodSupplies may be billed monthly using a daily rate.
    Transmitter Frequency
    ItemCGM transmitter.
    FrequencyOnce every three months.
    Unit allowanceOne unit per three months.
    Receiver Replacement Interval
    ItemCGM receiver.
    Useful lifetimeThree years.
    Replacement conditionReplacement or renewal requires documentation that the current receiver is no longer usable under the applicable replacement requirements.
    FreeStyle Libre 2 Sensor Limit
    ProductFreeStyle Libre 2 Sensor MISC.
    Quantity limit2 sensors.
    Limit periodPer 28 days.
    Dexcom G6 Sensor Limit
    ProductDexcom G6 Sensor MISC.
    Quantity limit3 sensors.
    Limit periodPer 30 days.
    Dexcom G7 Sensor Limit
    ProductDexcom G7 Sensor MISC.
    Quantity limit3 sensors.
    Limit periodPer 30 days.
    FreeStyle Libre 2 Plus Sensor Limit
    ProductFreeStyle Libre 2 Plus Sensor MISC.
    Quantity limit2 sensors.
    Limit periodPer 28 days.

    Unsupported block type: billing_rule

    Unsupported block type: denial_risk

    Unsupported block type: denial_risk

    Unsupported block type: denial_risk

    Unsupported block type: billing_rule

    Calibration is required daily.
    Factory-Calibrated Integrated CGM
    DefinitionA non-adjunctive, factory-calibrated, integrated CGM.
    Adjunctive statusThe system is non-adjunctive.
    Calibration and integrationThe system is factory-calibrated and integrated.
    Flash Monitor
    DefinitionA sensor-based, invasive, non-adjunctive, factory-calibrated glucose monitor initiated by the user.
    SensorThe monitor is sensor-based and invasive.
    Initiation and calibrationThe user initiates the monitor, which is factory-calibrated and non-adjunctive.
    Therapeutic CGM
    DefinitionA system approved by the FDA as a replacement for home blood glucose monitors.
    Clinical functionIt performs the medically necessary function of a home glucose monitor.
    Treatment decisionsIt is used to make diabetes treatment decisions.
    Non-Therapeutic CGM
    DefinitionA CGM device used as an adjunct to home blood glucose monitor testing rather than as a replacement.
    Medical functionIt does not perform a medically necessary function.
    FDA designationA CGM system without the FDA designation is considered non-therapeutic.
    Documentation Required

    Verify CGM benefit eligibility

    Verify that the requested CGM service or item is an eligible benefit under the member’s applicable benefit contract. Applicable benefit documents govern eligibility, benefit limits, and exclusions.