Loading...

    Explore
    • Policy Monitoring
    • Live Policy Feed
    • Billing Codes
    • Healthcare Providers
    • Health Insurance Payers
    • States
    • Service Lines
    • Taxonomy Codes
    Lookup tools
    • Billing Code Lookup
    • CPT Modifier Lookup
    • Provider Taxonomy Code Lookup
    • Healthcare Provider & Facility Lookup
    • Health Insurance Payer Lookup
    • Payer Contact Directory

    Policy & Benchmark Tools

    • Prior Authorization Lookup
    • Coverage Criteria Lookup
    • Timely Filing Lookup
    • Billing Code Reimbursement Rates
    • Payer Comparison Dashboard
    • Facility Comparison Dashboard
    • All tools

    Company

    • About OpenPayer
    • Data Sources
    • Trek Health
    OpenPayerby Trek Health
    LinkedInYouTube

    © 2026 Trek Health. All rights reserved.

    OpenPayer is built and maintained by Trek Health.

    v1.0.30
    OpenPayerPolicy UpdatesClinical/Medical PolicyOklahoma OHCA Long-Term EEG Prior Auth | OpenPayer
    Ask Trek AI about this page
    CurrentOklahoma Health Care AuthorityPolicy N/A

    Long-term Electroencephalographic (EEG) Monitoring

    Customize your policy alerts

    Sign up for all Oklahoma Health Care Authority policy alerts

    Know when Oklahoma Health Care Authority releases new policies or updates existing guidance.

    Monitor payer policy activity

    Receive email alerts as soon as relevant payer policies are published or updated.

    This guideline governs medical necessity and prior authorization for long-term continuous EEG and video-EEG monitoring, including technical and professional components. It applies to providers requesting or documenting these services for OHCA members.

    Policy Summary
    PayerOklahoma Health Care Authority
    PolicyLong-term Electroencephalographic (EEG) Monitoring
    Policy CodePolicy N/A
    Change TypeRevision of Existing Criteria
    Effective DateFebruary 3, 2021
    Next Review DateFebruary 2024
    Key ActionObtain prior authorization and submit medical-necessity documentation for listed EEG setup and long-term EEG/VEEG services.
    SourceLink
    POLICY UPDATE CHANGES

    No material clinical or coverage changes in this revision.

    ≥2 hoursMinimum long-term EEG duration

    OpenPayer is powered by Trek Health's payer performance platform. Trek continuously ingests, validates, and normalizes Transparency in Coverage data alongside payer policies and other commercial payer data to create a structured payer intelligence foundation. OpenPayer uses this foundation to deliver personalized search results, dynamically generated policy pages, and tailored policy monitoring based on each user's payers, specialties, billing codes, and areas of interest. The same intelligence powers broader payer performance workflows, including reimbursement benchmarking, contract evaluation, payer negotiations, and financial decision-making.

    72 hours
    Additional review threshold
    12 monthsExpected repeat frequency
    12Intermittent monitoring patient limit
    4Continuous monitoring patient limit
    27Covered EEG procedure codes

    Coverage Criteria

    General medical necessity and documentation

    Medical necessity and documentation requirements must all be met.

    General requirements

    • Required submission elements

      • Medical necessity must be met, supported by adequate objective medical records and evidence sufficient to justify the member’s need for the service.
      • Submit an order from a contracted qualified health professional involved in the patient’s treatment, requesting extended monitoring EEG or VEEG and specifying the number of units requested and the location where the service will be administered.
      • Submit clinical documentation including the diagnosis, history and physical examination, previous EEG results, and neuroimaging, if available.
      • Submit the current treatment plan; current medications; medications previously tried, failed, or contraindicated, including medication names and dates tried; and documentation of seizure activity, including frequency, intensity, and any hospitalizations.

    Covered indications

    Coverage is supported when ANY of the following indications applies.

    • Diagnostic and classification indications

      • Episodic events in which epilepsy is suspected but the history, examination, and routine EEG are inconclusive or nondiagnostic.
      • Differentiation between neurological, cardiac, or psychogenic origin of seizures when conventional tests are inconclusive or nondiagnostic.
      • Suspected non-epileptic events in a patient with confirmed epilepsy.
      • Classification of seizure type in a patient with confirmed epilepsy.
      • Localization of seizure focus in a patient with confirmed epilepsy.

    Repeat monitoring

    Repeat monitoring is subject to additional physician review when requested more frequently than once in 12 months.

    Additional repeat-study justification: The request must include physician review and documentation clearly describing why additional testing is necessary for diagnostic purposes or potential treatment adjustments.More frequently than once per 12 months

    Once a diagnosis has been established, this study is not expected to be repeated or used for monitoring a therapeutic regimen.

    Monitoring beyond 72 hours

    Monitoring beyond 72 hours requires additional review.

    Extended-duration monitoring: The request must include physician review and written documentation supporting each additional 24 hours of monitoring.>72 hours; each additional period is 24 hours

    Studies of neonates or unattended, non-cooperative patients are identified as contraindicated and do not meet coverage criteria.

    Localization of a seizure focus or foci is contraindicated when seizure symptoms or other EEG findings indicate bilateral foci or rapid generalization.

    Coding and Monitoring Parameters

    EEG SetupCPTCovered
    95700EEG Setup
    EEG Monitoring - Technical ComponentCPTCovered
    95705EEG, no video, monitoring technical component, 2-12 hours, unmonitored
    95706EEG, no video, monitoring technical component, 2-12 hours, intermittent
    95707EEG, no video, monitoring technical component, 2-12 hours, continuous
    95708EEG, no video, monitoring technical component, 12-26 hours, unmonitored
    95709EEG, no video, monitoring technical component, 12-26 hours, intermittent
    95710EEG, no video, monitoring technical component, 12-26 hours, continuous
    95711Video-EEG, monitoring technical component, 2-12 hours, unmonitored
    95712Video-EEG, monitoring technical component, 2-12 hours, intermittent
    95713Video-EEG, monitoring technical component, 2-12 hours, continuous
    95714Video-EEG, monitoring technical component, 12-26 hours, unmonitored
    1–10 of 12
    1/2
    EEG Monitoring - Professional ComponentCPTCovered
    95717Professional component, EEG no video, 2-12 hours, partial day
    95718Professional component, video EEG, 2-12 hours, partial day
    95719Professional component, EEG no video, 12-26 hours, full day
    95720Professional component, video EEG, 12-26 hours, full day
    95721Professional component, EEG no video, 36-60 hours, 2 days
    95722Professional component, video EEG, 36-60 hours, 2 days
    95723Professional component, EEG no video, 60-84 hours, 3 days
    95724Professional component, video EEG, 60-84 hours, 3 days
    95725Professional component, EEG no video, 84 hours or more, 4+ days
    95726Professional component, video EEG, 84 hours or more, 4+ days
    Long-term recording duration
    Minimum durationAt least 2 hours
    Recording distinctionTesting typically defined as less than 2 hours is distinguished from long-term continuous recording EEG
    Recording purposeLong-term recording captures brain-wave activity for clinical evaluation of seizures and other abnormalities
    Intermittent monitoring review interval
    Review intervalAt least every 2 hours during the entire recording
    Required documentationThe EEG technologist must perform and document real-time review of the data

    Authorization and Documentation Requirements

    Prior Authorization

    Obtain prior authorization before billing

    The listed EEG setup and long-term EEG/VEEG technical and professional component CPT codes require prior authorization. The request must demonstrate medical necessity and include the required order and clinical documentation.

    Documentation Required

    Include a qualified provider order

    Submit an order from a contracted qualified health professional involved in the patient’s treatment. The order must include the number of units requested and the location where the extended monitoring EEG/VEEG will be administered.

    Documentation Required

    Provide clinical records and prior testing

    Background

    Long-term EEG monitoring records brain-wave activity for at least 2 hours and may include synchronous video of the patient's clinical behavior. It is used to distinguish epileptic seizures from syncope, cardiac or sleep-related events, and psychogenic events; classify or localize seizures; evaluate seizure frequency and treatment response; and support epilepsy surgery evaluation. Technical services may be unmonitored, intermittently monitored, or continuously monitored, while professional services include qualified review, interpretation, and reporting.

    Definitions

    Electroencephalogram (EEG)
    PurposeA diagnostic test used to measure the electrical activity of the brain
    EquipmentHighly sensitive recording equipment is attached to the scalp by fine electrodes
    Typical durationTesting is typically less than 2 hours
    EEG technologist
    QualificationQualified through education, training, and licensure, certification, or regulation when applicable in seizure recognition
    Core responsibilitiesPerforms EEG setup, takedown when performed, patient education, technical descriptions, and equipment maintenance
    Clinical responsibility
    Policy Summary
    PayerOklahoma Health Care Authority
    PolicyLong-term Electroencephalographic (EEG) Monitoring
    Policy CodePolicy N/A
    Change TypeRevision of Existing Criteria
    Effective DateFebruary 3, 2021
    Next Review DateFebruary 2024
    Key ActionObtain prior authorization and submit medical-necessity documentation for listed EEG setup and long-term EEG/VEEG services.
    SourceLink
    On This Page
    Coverage CriteriaCoding and Monitoring ParametersAuthorization and Documentation RequirementsBackgroundDefinitions
  1. Identification of absence seizures, including blanking out or staring, for medication management.
  2. Suspected seizures associated with sleep disturbances when routine EEG is inconclusive or nondiagnostic.
  3. Seizures precipitated by naturally occurring cyclic events or environmental stimuli that are not reproducible in a hospital or clinic setting, when routine EEG is inconclusive or nondiagnostic.
  4. Surgical evaluation

    • Pre-operative evaluation of a patient undergoing epilepsy surgery.
  5. Review purposeReview supports recording integrity and quality, identifies maintenance needs, and allows clinical issues to be reported to the physician or other qualified health care professional
    Intermittent concurrent patient limit
    Concurrent patient limitMaximum 12 patients
    Monitoring modeIntermittent monitoring may be provided remotely or on-site
    Exceeding the limitIf the number of patients exceeds 12, the study is considered unmonitored
    Continuous concurrent patient limit
    Concurrent patient limitMaximum 4 patients
    Monitoring requirementThe EEG technologist must perform and document concurrent real-time monitoring of EEG data and video when video is performed
    Exceeding the limitIf the patient number exceeds 4, the study is considered intermittent monitoring
    Extended monitoring review threshold
    Review thresholdMonitoring beyond 72 hours
    Documentation intervalWritten documentation is required for each additional 24 hours of monitoring
    Review requirementPhysician review is required
    Repeat monitoring frequency
    Frequency thresholdMore frequently than once in a 12-month period
    Review requirementPhysician review is required
    Additional justificationDocumentation must clearly explain why additional testing is necessary for diagnostic purposes or potential treatment adjustments

    Submit clinical documentation including the diagnosis, history and physical examination, previous EEG results, and neuroimaging when available.

    Documentation Required

    Document treatment and seizure history

    Document the current treatment plan, current medications, and medications previously tried, failed, or contraindicated. Include medication names and dates tried, along with seizure activity details, including frequency, intensity, and any hospitalizations.

    Documentation Required

    Submit additional physician review

    For monitoring beyond 72 hours or testing more frequently than once in a 12-month period, provide physician-review documentation explaining the need for the additional monitoring or repeat diagnostic study.

    Denial Risk

    Demonstrate medical necessity

    The request may be denied when medical necessity is not demonstrated through adequate objective medical records sufficient to justify the member’s need for the service.

    Denial Risk

    Complete all supporting documentation

    Requests may be denied or pended when required supporting information is missing, including the order, requested units, service location, clinical history, prior testing, treatment information, or seizure documentation.

    Denial Risk

    Support each additional 24 hours

    Monitoring beyond 72 hours requires physician review and written documentation supporting each additional 24-hour period of monitoring.

    Denial Risk

    Justify repeat monitoring

    Long-term EEG monitoring requested more frequently than once in a 12-month period requires physician review and clear documentation explaining why additional testing is necessary for diagnostic purposes or potential treatment adjustments.

    Denial Risk

    Avoid contraindicated indications

    The guideline identifies studies of neonates or unattended, non-cooperative patients as contraindicated. Seizure-focus localization is also contraindicated when seizure symptoms or EEG findings indicate bilateral foci or rapid generalization.

    Performs seizure recognition within the applicable scope of practice and as allowed by law, regulation, and facility policy
    Long-term continuous recording EEG
    Minimum durationEEG recording for a duration equal to or greater than 2 hours
    Diagnostic purposesUsed to differentiate seizures from other abnormalities and determine seizure type or location
    Additional usesMay monitor treatment or status epilepticus, evaluate epilepsy surgery candidacy, or screen for adverse change in critically ill patients
    Status epilepticus
    DefinitionA dangerous condition in which epileptic seizures follow one another without recovery of consciousness between them
    Medical significanceIt is a life-threatening medical emergency
    RiskTreatment delay can result in a life-threatening emergency
    Video EEG monitoring (VEEG)
    Recording methodSynchronous recording and display of EEG patterns and videorecorded clinical behavior
    DurationTypically conducted over several days
    Clinical usesCorrelates electrophysiological changes with behavior, distinguishes epileptic from non-epileptic events, and identifies the brain area from which seizures arise
    Intermittent monitoring
    Review intervalAn EEG technologist performs and documents real-time review at least every 2 hours throughout the recording
    Review purposeReview assures recording integrity and quality, identifies maintenance needs, and supports notification of clinical issues
    Concurrent patient limitThe technologist may monitor no more than 12 patients concurrently
    Continuous real-time monitoring
    Core requirementIncludes all intermittent-monitoring requirements
    Real-time monitoringThe technologist performs and documents concurrent real-time monitoring of EEG data and video when performed throughout the recording
    Patient limit and downgradeA technologist may monitor no more than 4 patients concurrently; a break in real-time monitoring or more than 4 patients makes the study intermittent monitoring