Loading...

    Explore
    • Policy Monitoring
    • Live Policy Feed
    • Billing Codes
    • Healthcare Providers
    • Health Insurance Payers
    • States
    • Service Lines
    • Taxonomy Codes
    Lookup tools
    • Billing Code Lookup
    • CPT Modifier Lookup
    • Provider Taxonomy Code Lookup
    • Healthcare Provider & Facility Lookup
    • Health Insurance Payer Lookup
    • Payer Contact Directory

    Policy & Benchmark Tools

    • Prior Authorization Lookup
    • Coverage Criteria Lookup
    • Timely Filing Lookup
    • Billing Code Reimbursement Rates
    • Payer Comparison Dashboard
    • Facility Comparison Dashboard
    • All tools

    Company

    • About OpenPayer
    • Data Sources
    • Request a Policy / Feedback
    • Trek Health
    OpenPayerby Trek Health
    LinkedInYouTube

    © 2026 Trek Health. All rights reserved.

    OpenPayer is built and maintained by Trek Health.

    v1.0.32
    OpenPayerPolicy UpdatesOtorhinolaryngology (ENT)MedStar DC Hearing Aid Coverage Policy | OpenPayer
    Ask Trek AI about this page
    CurrentMedStar Family Choice District of ColumbiaPolicy 1421.DC

    Hearing Aid Coverage

    Customize your policy alerts

    Sign up for medstarfamilychoicedistrictofcolumbia Policy 1421.DC alerts

    Get alerted when Policy 1421.DC changes without checking for updates manually.

    Monitor payer policy activity

    Receive email alerts as soon as relevant payer policies are published or updated.

    This policy governs authorization of hearing aids, auditory osseointegrated devices, bone-anchored hearing aids, and related audiology services for MedStar Family Choice District of Columbia enrollees with hearing loss. Coverage requires medical necessity and satisfaction of age-specific, audiologic, medical, device, and documentation criteria.

    Policy Summary
    PayerMedStar Family Choice District of Columbia
    PolicyHearing Aid Coverage
    Policy CodePolicy 1421.DC
    Change TypeMaterial revision
    Effective DateJul 1, 2026
    Last ReviewJul 1, 2023
    Next Review DateN/A
    Key ActionObtain authorization before providing covered hearing aids or hearing devices and submit the required audiologic evaluation, audiogram, fitting documentation, and medical clearance when required.
    SourceLink
    POLICY UPDATE CHANGES

    Coverage was added for nonimplantable or soft-band auditory osseointegrated devices for enrollees younger than 5 years of age when clinically indicated.

    The criteria for auditory osseointegrated devices and bone-anchored hearing aids were updated.

    Adult bilateral hearing aid indications were broadened to remove the prior child-under-21 limitation for successful bilateral users and to add community settings as a qualifying setting.

    Limitations and exclusions for hearing aids, devices, and audiology services were clarified.

    OpenPayer is powered by Trek Health's payer performance platform. Trek continuously ingests, validates, and normalizes Transparency in Coverage data alongside payer policies and other commercial payer data to create a structured payer intelligence foundation. OpenPayer uses this foundation to deliver personalized search results, dynamically generated policy pages, and tailored policy monitoring based on each user's payers, specialties, billing codes, and areas of interest. The same intelligence powers broader payer performance workflows, including reimbursement benchmarking, contract evaluation, payer negotiations, and financial decision-making.

    25 dB HLMinimum hearing loss threshold for children under 21
    40 dB HLAdult unilateral hearing aid PTA threshold
    5 yearsAge threshold for standard auditory osseointegrated devices
    45–65 dBBAHA bone-conduction PTA range
    6 monthsMedical examination window for initial clearance
    8Listed coverage limitations and exclusions

    Hearing Aid and Device Coverage Criteria

    Children under 21

    Covered when ALL of the following are met:

    Pediatric hearing aid criteria

    • Age and device: The participant is younger than 21 years of age and seeks bilateral or unilateral hearing aids.
    • Hearing loss and fitting

      • Hearing loss: The participant has hearing loss of 25 dB HL or greater.>= 25 dB HL
      • Recommendation and fitting: The hearing aid or aids are recommended and fitted by an audiologist.
      • Initial device clearance: For an initial hearing aid, written medical clearance is obtained from a physician who performed a medical examination within the past 6 months.within 6 months

    Adults 21 years and older

    Covered when ALL unilateral criteria are met; bilateral coverage additionally requires one qualifying condition:

    Adult hearing aid criteria

    • Unilateral hearing aid criteria

      • Audiologic threshold: The pure tone average threshold is 40 dB HL or greater at 500, 1,000, 2,000, and 3,000 Hz in the better ear.>= 40 dB HL
      • Functional ability: The patient is alert and able to utilize the aid appropriately.
      • Recommendation and fitting: The hearing aid is recommended and fitted by an audiologist.

    Auditory osseointegrated devices and bone-anchored hearing aids

    Covered when ALL of the applicable age, audiologic, implant, and medical criteria are met:

    Auditory osseointegrated device or BAHA criteria

    • Age: The enrollee is 5 years of age or older. Nonimplantable or soft-band devices may be covered for participants younger than 5 years of age when clinically indicated.age >= 5 years for standard devices
    • Implant configuration — ONE of

      • Unilateral implant: The participant has conductive or mixed hearing loss with a pure tone average bone-conduction threshold at 500, 1,000, 2,000, and 3,000 Hz within the applicable device-specific limit.<= 45 dB for BAHA Attract, BAHA Divino, BAHA BP100, Baha 4, and Sophono Alpha System; <= 55 dB for BAHA 5 Power, BAHA Intenso, and Ponto Plus Power; <= 65 dB for BAHA Cordelle II
      • Bilateral implants

    Acceptable devices and audiology services

    Covered devices and services include ALL of the following:

    Acceptable hearing aids, devices, and audiology services

    • Hearing aids and devices: The hearing aid or device is FDA approved and listed in the District of Columbia Medicaid Fee Schedule.
    • Audiology services: The audiology service is listed in the District of Columbia Medicaid Fee Schedule.

    Replacement of a hearing aid is not covered when the existing device remains functional, repairable, and appropriately effective in correcting or ameliorating the patient’s hearing-related problem or condition.

    Replacement of an improperly fitted ear mold is not covered unless the replacement is provided by someone other than the original provider and the replacement service has not been claimed previously.

    Additional professional fees and overhead charges for a new hearing aid are not covered when a dispensing fee claim has already been submitted to the program.

    Loaner hearing aids are not covered.

    Hearing aids that are not FDA approved are not covered.

    Hearing aids that are not listed on the District of Columbia Medicaid Fee Schedule are not covered.

    Audiology services that are not listed on the District of Columbia Medicaid Fee Schedule are not covered.

    Use of hearing aids for conditions other than hearing loss, including tinnitus, is not covered.

    Audiologic Thresholds and Device Parameters

    Children Under 21 Hearing Loss
    Minimum hearing lossAt least 25 dB HL
    Applicable populationChildren under 21 years of age
    Covered devicesBilateral or unilateral hearing aids
    Adults Unilateral Hearing Aid PTA
    Better-ear PTA thresholdAt least 40 dB HL
    Test frequencies500, 1,000, 2,000, and 3,000 Hz
    Applicable hearing aidAdult unilateral hearing aid

    Authorization and Documentation Requirements

    Prior Authorization

    Prior Authorization Required for Hearing Aids

    Prior authorization is required for hearing aids. MedStar Family Choice District of Columbia authorizes hearing aids only when medically necessary and the applicable coverage criteria are met; requests that do not specifically meet the criteria may be submitted with supporting medical records and relevant literature for Medical Director review as a medical exception.

    • Submit documentation supporting the participant’s age, hearing loss, audiologic findings, audiologist recommendation and fitting, required medical clearance, and any applicable functional-use or bilateral-benefit criteria.
    • Hearing aids and audiology services must be FDA approved and listed on the District of Columbia Medicaid Fee Schedule.
    Prior Authorization

    Prior Authorization for BAHA Devices

    Prior authorization and medical-necessity review apply to auditory osseointegrated devices and bone anchored hearing aids (BAHA). Coverage requires the applicable age, hearing-loss, bone-conduction threshold, device, and conventional-hearing-aid contraindication criteria.

    • The enrollee must be age 5 or older; nonimplantable or soft-band devices may be covered for participants younger than 5 or when clinically indicated.

    Clinical Background

    Hearing loss may be sensorineural, conductive, or mixed. Hearing aids may benefit children and motivated, independent adults when hearing loss interferes with school, work, or other functioning. Auditory osseointegrated and bone-anchored devices may be used for conductive or mixed hearing loss when an anatomic or medical condition prevents use of a conventional air-conduction hearing aid.

    Hearing and Audiology Definitions

    Sensorineural Hearing Loss
    DefinitionHearing loss involving the inner ear, cochlea, or auditory nerve
    Affected structuresInner ear and cochlea
    Neural involvementMay involve the auditory nerve
    Conductive Hearing Loss
    DefinitionHearing loss caused by limitation of external sound reaching the inner ear
    Representative causesCerumen impaction or middle ear fluid
    Additional causeOssicular chain fixation, meaning lack of movement of the small bones in the ear
    Policy Summary
    PayerMedStar Family Choice District of Columbia
    PolicyHearing Aid Coverage
    Policy CodePolicy 1421.DC
    Change TypeMaterial revision
    Effective DateJul 1, 2026
    Last ReviewJul 1, 2023
    Next Review DateN/A
    Key ActionObtain authorization before providing covered hearing aids or hearing devices and submit the required audiologic evaluation, audiogram, fitting documentation, and medical clearance when required.
    SourceLink
    On This Page
    Hearing Aid and Device Coverage CriteriaAudiologic Thresholds and Device ParametersAuthorization and Documentation RequirementsClinical BackgroundHearing and Audiology Definitions
    Initial device clearance: For an initial hearing aid, written medical clearance is obtained from a physician who performed a medical examination within the past 6 months.within 6 months
  1. Additional bilateral criterion — ONE of

    • Statutory blindness: The participant has visual impairment meeting the definition of statutory blindness.
    • Previous successful bilateral user: The participant is a previous successful bilateral hearing aid user and meaningful objective benefit over unilateral amplification can be documented.
    • Significant hearing-related disability: The participant demonstrates significant hearing-related disability in educational, vocational, or community settings with a unilateral aid, and meaningful objective benefit from bilateral aids can be documented.
    • Bilateral symmetry: Bone-conduction thresholds are symmetric, defined as less than a 10 dB average difference between ears or less than a 15 dB difference at individual frequencies, measured at the frequencies specified for the applicable device group.< 10 dB average difference between ears or < 15 dB at individual frequencies
  2. Medical contraindication to conventional air-conduction hearing aid — ONE of

    • Congenital or surgically induced ear canal malformation: Congenital atresia or a surgically induced malformation leaves the ear canal absent or unable to accommodate a standard hearing aid, provided that the nerve is functional.
    • Severe chronic ear infection: Severe chronic infection of the middle or outer ear is exacerbated by a standard hearing aid.
    • External ear canal dermatitis or hypersensitivity: Dermatitis of the external ear canal, including hypersensitivity to ear molds used in air-conduction hearing aids.
    • Tumor of the external ear canal or tympanic cavity.
    • Other contraindicating condition: Another anatomic or medical condition contraindicates use of an air-conduction hearing aid.
  3. Unilateral BAHA Bone-Conduction PTA
    BAHA Attract, BAHA Divino, BAHA BP100, Baha 4, and Sophono Alpha SystemBone-conduction PTA less than or equal to 45 dB at 500, 1,000, 2,000, and 3,000 Hz
    BAHA 5 Power, BAHA Intenso, and Ponto Plus PowerBone-conduction PTA less than or equal to 55 dB at 500, 1,000, 2,000, and 3,000 Hz
    BAHA Cordelle IIBone-conduction PTA less than or equal to 65 dB at 500, 1,000, 2,000, and 3,000 Hz
    Bilateral BAHA Symmetry
    Average inter-ear differenceLess than 10 dB average difference between ears
    Individual-frequency differenceLess than 15 dB difference at individual frequencies
    Frequencies for BAHA Divino, Ponto Plus, Ponto Plus Power, Ponto Pro, and Sophono Alpha SystemAverage measured at 500, 1,000, 2,000, and 4,000 Hz
    Frequencies for BAHA Attract, BAHA BP100, Baha 4, BAHA 5 Power, BAHA Cordelle II, and BAHA IntensoAverage measured at 500, 1,000, 2,000, and 3,000 Hz
  4. For a unilateral implant, the enrollee must have conductive or mixed hearing loss and a pure-tone average bone-conduction threshold at 500, 1,000, 2,000, and 3,000 Hz of ≤45 dB for BAHA Attract, BAHA Divino, BAHA BP100, Baha 4, or Sophono Alpha System; ≤55 dB for BAHA 5 Power, BAHA Intenso, or Ponto Plus Power; or ≤65 dB for BAHA Cordelle II.
  5. The requested device must be an FDA-approved device listed on the District of Columbia Medicaid Fee Schedule.
  6. Documentation Required

    Audiologist Evaluation and Audiogram Required

    Submit an audiologist evaluation with an audiogram for hearing-aid review. The audiologist must recommend and fit the hearing aid when that criterion applies.

    • Include audiologic findings sufficient to establish the applicable hearing-loss threshold, pure-tone average, and—when applicable—bone-conduction results.
    • Audiology services must be listed on the District of Columbia Medicaid Fee Schedule.
    Documentation Required

    Initial Hearing Aid Medical Clearance

    For an initial hearing aid, obtain written medical clearance from a physician who performed a medical examination within the preceding six months.

    • The six-month medical-examination and written-clearance requirement applies to initial hearing aids for children and adults.
    • Submit the written clearance with the prior-authorization request.
    Documentation Required

    Document Ability to Use the Hearing Aid

    For an adult age 21 or older requesting a unilateral hearing aid, document that the participant is alert and able to utilize the hearing aid appropriately.

    • This functional-use documentation is required in addition to the adult audiologic threshold, audiologist recommendation and fitting, and initial medical-clearance requirements when applicable.
    Documentation Required

    Document Objective Bilateral Benefit

    Bilateral hearing aids for adults require the unilateral-hearing-aid criteria plus documentation of meaningful objective benefit from bilateral amplification and at least one qualifying circumstance.

    • The participant is statutorily blind.
    • The participant is a previous successful bilateral hearing-aid user and meaningful objective benefit over unilateral amplification can be documented.
    • The participant has significant hearing-related disability in educational, vocational, or community settings with a unilateral aid and meaningful objective benefit from bilateral aids can be documented.
    Documentation Required

    BAHA Bilateral Symmetry and Contraindication Documentation

    For bilateral BAHA implants, document moderate-to-severe bilateral symmetric conductive or mixed hearing loss, with the applicable bone-conduction thresholds met in both ears, and a medical condition that prevents use of a conventional air-conduction hearing aid.

    • Symmetry requires either less than a 10 dB average interaural difference at 500, 1,000, 2,000, and 4,000 Hz or less than a 15 dB difference at individual frequencies for BAHA Divino, Ponto Plus, Ponto Plus Power, Ponto Pro, or Sophono Alpha System.
    • For BAHA Attract, BAHA BP100, BAHA 4, BAHA 5 Power, BAHA Cordelle II, or BAHA Intenso, symmetry requires less than a 10 dB average interaural difference at 500, 1,000, 2,000, and 3,000 Hz or less than a 15 dB difference at individual frequencies.
    • Qualifying contraindications include congenital atresia or surgically induced ear-canal malformation that prevents accommodation of a standard hearing aid when the nerve is functional; severe chronic middle- or outer-ear infection exacerbated by a standard hearing aid; external-ear-canal dermatitis, including hypersensitivity to air-conduction ear molds; tumors of the external ear canal and/or tympanic cavity; or other anatomic or medical conditions contraindicating an air-conduction hearing aid.
    Denial Risk

    Excluded Devices, Services, and Replacements

    Do not request or bill excluded devices, services, or replacements. These items are not covered under this policy or are subject to the stated replacement and billing limitations.

    • Replacement hearing aids when existing devices are functional, repairable, and appropriately correct or ameliorate the condition.
    • Replacement of improperly fitted ear molds unless the replacement is provided by someone other than the original provider and the replacement service has not previously been claimed.
    • Additional professional fees or overhead charges for a new hearing aid when a dispensing-fee claim has already been made to the program.
    • Loaner hearing aids.
    • Hearing aids that are not FDA approved or are not listed on the District of Columbia Medicaid Fee Schedule.
    • Audiology services that are not listed on the District of Columbia Medicaid Fee Schedule.
    • Use of hearing aids for conditions other than hearing loss, including tinnitus.
    Denial Risk

    Failure to Meet Medical-Necessity Criteria

    Requests may be denied when the applicable medical-necessity criteria are not met or the required documentation is missing. This includes failures involving age, audiologic thresholds, recommendation and fitting, medical clearance, functional ability, bilateral benefit, BAHA device thresholds, symmetry, or contraindications to conventional amplification.

    • Children under 21: hearing loss must be ≥25 dB HL, the hearing aid must be recommended and fitted by an audiologist, and an initial device requires timely written physician clearance.
    • Adults 21 and older: unilateral coverage requires a pure-tone average of ≥40 dB HL at 500, 1,000, 2,000, and 3,000 Hz in the better ear, documented ability to use the aid, audiologist recommendation and fitting, and timely initial medical clearance.
    • Adult bilateral coverage requires the unilateral criteria plus statutory blindness, previous successful bilateral use with documented meaningful objective benefit, or qualifying hearing-related disability with documented meaningful objective bilateral benefit.
    • BAHA coverage requires the applicable age, conductive or mixed hearing loss, bone-conduction threshold, bilateral symmetry when applicable, and a documented condition preventing use of a conventional air-conduction hearing aid.
    Mixed Hearing Loss
    DefinitionA combination of conductive and sensorineural hearing loss
    Conductive componentIncludes limitation of external sound reaching the inner ear
    Sensorineural componentInvolves the inner ear, cochlea, or auditory nerve
    Pure Tone Average (PTA)
    DefinitionThe average of hearing threshold levels at a set of specified frequencies
    What is averagedHearing threshold levels
    Frequency basisA specified set of frequencies
    Statutory Blindness
    Visual acuity thresholdCentral visual acuity of 20/200 or less
    Eye measuredThe better eye
    Correction and statutory referenceMeasured with use of a correcting lens, as defined under Sections 216(i)(1) and 1614(a)(2) of the Social Security Act
    dB HL
    AbbreviationdB HL
    MeaningDecibels hearing level
    UseUsed to express hearing thresholds