Loading...

    Explore
    • Policy Monitoring
    • Live Policy Feed
    • Billing Codes
    • Healthcare Providers
    • Health Insurance Payers
    • States
    • Service Lines
    • Taxonomy Codes
    Lookup tools
    • Billing Code Lookup
    • CPT Modifier Lookup
    • Provider Taxonomy Code Lookup
    • Healthcare Provider & Facility Lookup
    • Health Insurance Payer Lookup
    • Payer Contact Directory

    Policy & Benchmark Tools

    • Prior Authorization Lookup
    • Coverage Criteria Lookup
    • Timely Filing Lookup
    • Billing Code Reimbursement Rates
    • Payer Comparison Dashboard
    • Facility Comparison Dashboard
    • All tools

    Company

    • About OpenPayer
    • Data Sources
    • Request a Policy / Feedback
    • Trek Health
    OpenPayerby Trek Health
    LinkedInYouTube

    © 2026 Trek Health. All rights reserved.

    OpenPayer is built and maintained by Trek Health.

    v1.0.32
    OpenPayerPolicy UpdatesDurable Medical Equipment (DME)MedStar Family Choice Lymphedema Prior Auth | Open…
    Ask Trek AI about this page
    CurrentMedStar Family Choice District of ColumbiaPolicy 1419

    Pneumatic Compression Devices for Lymphedema

    Customize your policy alerts

    Sign up for medstarfamilychoicedistrictofcolumbia Policy 1419 alerts

    Get alerted when Policy 1419 changes without checking for updates manually.

    Monitor payer policy activity

    Receive email alerts as soon as relevant payer policies are published or updated.

    This policy governs when pneumatic compression devices are medically necessary and may be authorized for home use for lymphedema or chronic venous insufficiency with venous stasis ulcers. It applies to MedStar Family Choice members in Maryland and requires prior authorization with supporting clinical documentation.

    Policy Summary
    PayerMedStar Family Choice District of Columbia
    PolicyPneumatic Compression Devices for Lymphedema
    Policy CodePolicy 1419
    Change TypeMaterial update
    Effective DateJul 1, 2026
    Last ReviewJul 1, 2025
    Next Review DateN/A
    Key ActionObtain prior authorization and submit supporting clinical information for pneumatic compression devices.
    SourceLink

    OpenPayer is powered by Trek Health's payer performance platform. Trek continuously ingests, validates, and normalizes Transparency in Coverage data alongside payer policies and other commercial payer data to create a structured payer intelligence foundation. OpenPayer uses this foundation to deliver personalized search results, dynamically generated policy pages, and tailored policy monitoring based on each user's payers, specialties, billing codes, and areas of interest. The same intelligence powers broader payer performance workflows, including reimbursement benchmarking, contract evaluation, payer negotiations, and financial decision-making.

    POLICY UPDATE CHANGES

    The policy removed retired LCD L33829 and its associated requirements.

    The policy clarified that an advanced E0652 device is not covered without lymphedema extending onto the chest, trunk, or abdomen.

    The policy added documentation that the member or caregiver can apply the device at the prescribed frequency.

    2Covered clinical indications
    4 weeksLymphedema therapy minimum
    6 monthsCVI ulcer therapy minimum
    E0652Advanced device
    Prior authorizationAuthorization requirement

    Coverage Criteria

    Covered Clinical Indications

    Pneumatic compression devices (PCDs) are medically necessary in the home setting when ALL applicable criteria are met.

    ONE of the following covered indications

    • Lymphedema

      • Confirmed diagnosis of lymphedema.
      • At least 4 weeks of conservative therapy, including compression garments or bandaging, exercise, and elevation.>= 4 weeks
      • Persistent symptoms or no meaningful improvement after the conservative therapy trial.
    • Chronic venous insufficiency with venous stasis ulcers

      • Diagnosis of chronic venous insufficiency (CVI).
      • One or more venous stasis ulcers.
      • At least 6 months of conservative therapy, including compression therapy, wound care, exercise, and elevation.>= 6 months
      • Failure of ulcer healing after at least 6 months of conservative therapy.

    Clinical Need for Pneumatic Compression

    Pneumatic compression is medically necessary only when ALL of the following clinical-need criteria are met.

    ALL of the following

    • Compression therapy has

      • Failed.
      • Not been tolerated.
      • Been unable to be applied.
    • The patient has

      • Refractory edema.
      • Lymphatic obstruction.

    Advanced Calibrated-Gradient Device (E0652)

    An advanced segmented pneumatic compressor with calibrated gradient pressure (E0652) is covered only when ALL of the following criteria are met.

    ALL of the following

    • Standard pneumatic compression devices (E0650 or E0651) are ineffective.
    • The patient requires individualized pressure control due to unique clinical factors.

      Compatible appliances include E0656, E0657, E0658, E0659, E0667, E0668, E0669, and E0670.

    Pneumatic compression must be used as an adjunct after appropriate conservative management, not as first-line treatment without clinical justification. Coverage also requires properly fitted garments, patient compliance, complete supporting documentation, and use under the direction of a qualified licensed practitioner.

    A calibrated-gradient device provides compressor-generated, calibrated pressure that progresses along the treated extremity. A gradient created solely by sleeves or tubing does not qualify as calibrated gradient pressure.

    Conservative therapy must be completed before pneumatic compression is initiated. The applicable conservative-therapy period is at least 4 weeks for lymphedema and at least 6 months for chronic venous insufficiency with venous stasis ulcers.

    Compression therapy must be attempted before pneumatic compression unless compression therapy is contraindicated. The record must document that compression therapy failed, was not tolerated, or could not be applied when pneumatic compression is being used to address the qualifying clinical need.

    E0652 requires documentation that a standard device (E0650 or E0651) was ineffective, or that the patient requires individualized pressure control because of unique clinical factors. Use of E0652 as a first-line device without this justification is not medically necessary.

    Covered Codes and Coding Thresholds

    Non-Segmented Pneumatic CompressorHCPCSCovered
    E0650Non-segmented pneumatic compressor
    Appliances Compatible with E0650HCPCSCovered
    E0655Compatible appliance for E0650 device
    E0660Compatible appliance for E0650 device
    E0665Compatible appliance for E0650 device
    E0666Compatible appliance for E0650 device
    E0671Compatible appliance for E0650 device
    E0672Compatible appliance for E0650 device
    E0673Compatible appliance for E0650 device
    Segmental Gradient AppliancesHCPCSCovered
    E0671Segmental gradient appliance
    E0672Segmental gradient appliance
    E0673Segmental gradient appliance
    Segmented Pneumatic Compressors Without Calibrated Gradient PressureHCPCSCovered
    E0651Segmented pneumatic compressor without calibrated gradient pressure
    Appliances Compatible with E0651HCPCSCovered
    E0667Compatible appliance for E0651 device
    E0668Compatible appliance for E0651 device
    E0669Compatible appliance for E0651 device
    Segmented Pneumatic Compressors With Calibrated Gradient PressureHCPCSCovered
    E0652Segmented pneumatic compressor with calibrated gradient pressure
    Appliances Compatible with E0652HCPCSCovered
    E0656Compatible appliance for E0652 device
    E0657Compatible appliance for E0652 device
    E0658Compatible appliance for E0652 device
    E0659Compatible appliance for E0652 device
    E0667Compatible appliance for E0652 device
    E0668Compatible appliance for E0652 device
    E0669Compatible appliance for E0652 device
    E0670Compatible appliance for E0652 device
    Lymphedema Conservative Therapy
    Minimum trial duration≥ 4 weeks
    Required conservative therapyCompression garments or bandaging, exercise, and elevation
    Required treatment responsePersistent symptoms or no meaningful improvement after the trial
    CVI With Venous Stasis Ulcers
    Minimum treatment period≥ 6 months
    Required conservative therapy

    Authorization and Provider Actions

    Prior Authorization

    Prior Authorization Required

    Prior authorization is required for all pneumatic compression devices. Requests must be reviewed before the device is provided or used.

    Step Therapy

    Conservative Therapy Before Device Use

    Before device use, document completion of the applicable conservative-therapy trial and the patient’s response. Pneumatic compression is medically necessary when compression therapy has failed, is not tolerated, or cannot be applied, and the patient has refractory edema, lymphatic obstruction, or non-healing ulcers.

    • For lymphedema: confirmed diagnosis plus at least 4 weeks of conservative therapy, including compression garments or bandaging, exercise, and elevation; symptoms must persist or show no meaningful improvement.
    • For chronic venous insufficiency with venous stasis ulcers: diagnosis of CVI, at least one venous stasis ulcer, and at least 6 months of compression therapy, wound care, exercise, and elevation, with failure of ulcer healing.
    • Compression therapy must be attempted unless contraindicated; garments must be properly fitted and used compliantly.

    Clinical Background

    Chronic venous insufficiency may involve significant edema, skin changes, and venous ulceration. Initial management generally includes leg elevation, exercise, and static compression therapy; patients with refractory disease may require intermittent pneumatic compression.

    Device Definitions

    Non-Segmented Pneumatic Compressor
    Compressor configurationSingle-chamber, non-segmented, non-programmable compressor
    Outflow portsOne outflow port
    Garment operationGarment inflation and deflation follow the pressure and cycle times specified by the pump
    Segmented Pneumatic Compressor Without Calibrated Gradient Pressure
    Compressor configurationMulti-chamber, segmented, non-programmable pump
    Inflation patternGarment segments inflate sequentially at fixed pressure in each compartment
    Pressure adjustment

    General DME Medical Necessity

    General DME Medical Necessity

    The home pneumatic compression device must meet all of the following general medical-necessity requirements.

    General DME medical necessity

    • The device is prescribed by a physician.
    • The device is used with appropriate clinical oversight.
    • The patient has qualifying lymphedema or chronic venous insufficiency with venous stasis ulcers.
    • The applicable conservative-therapy requirements are met.
    • The patient has persistent or refractory symptoms, lymphatic obstruction, or non-healing ulcers, as applicable to the qualifying condition.

    Required Clinical Documentation

    Documentation Required

    Complete the medical-necessity record

    Submit complete documentation supporting medical necessity and the selected compressor type. Include the diagnosis and prognosis, objective findings such as limb measurements or ulcer size, severity, prior treatments and outcomes, and the clinical rationale for device selection.

    Documentation Required

    Record physician oversight and the treatment plan

    Document physician confirmation of the need for therapy, training on device use, and a treatment plan that establishes pressure, duration, and frequency.

    • Include ongoing monitoring.
    Documentation Required

    Document response and safe home operation

    Document clinical improvement, treatment tolerance, and safe device use. Also record that the member or caregiver can apply the device at the prescribed frequency.

    Non-Covered Circumstances

    E0652 is not covered without demonstrated ineffectiveness of standard E0650 or E0651 devices and a clinical need for individualized pressure control. It is also not covered without lymphedema extending onto the chest, trunk, or abdomen.

    Policy Summary
    PayerMedStar Family Choice District of Columbia
    PolicyPneumatic Compression Devices for Lymphedema
    Policy CodePolicy 1419
    Change TypeMaterial update
    Effective DateJul 1, 2026
    Last ReviewJul 1, 2025
    Next Review DateN/A
    Key ActionObtain prior authorization and submit supporting clinical information for pneumatic compression devices.
    SourceLink
    On This Page
    Coverage CriteriaCovered Codes and Coding ThresholdsAuthorization and Provider ActionsClinical BackgroundDevice DefinitionsGeneral DME Medical NecessityRequired Clinical DocumentationNon-Covered Circumstances
  1. Non-healing ulcers.
  2. Compression therapy, wound care, exercise, and elevation
    Required treatment responseFailure of ulcer healing after ≥ 6 months of conservative therapy
    Individually Adjustable Pressure Segments
    Minimum adjustable segmentsAt least 3 outflow ports
    Pressure controlManual adjustment of pressure on the outflow ports
    Clinical functionDelivers individually determined pressure to corresponding garment segments
    Step Therapy

    Advanced Device Requirements

    An E0652 segmented pneumatic compressor with calibrated gradient pressure is covered only when standard devices are ineffective and the patient requires individualized pressure control because of unique clinical factors. Gradient produced solely by sleeves or tubing does not qualify as calibrated gradient pressure.

    • Standard devices E0650/E0651 must be shown to be ineffective.
    • Document the unique clinical factors supporting individualized pressure control.
    • E0652 is not covered without lymphedema extending onto the chest, trunk, or abdomen.
    • Compatible appliances include E0656, E0657, E0658, E0659, E0667, E0668, E0669, and E0670.
    Documentation Required

    Clinical Documentation

    The medical record must establish the diagnosis, expected prognosis, objective findings, severity, prior treatment history, outcomes, and the clinical rationale for selecting the requested device and compressor type.

    • Include objective findings such as limb measurements and ulcer size.
    • Describe prior treatments and outcomes, including conservative-therapy response.
    • Explain why the requested device type is clinically appropriate.
    Documentation Required

    Physician Oversight

    A qualified licensed practitioner must oversee therapy and document the evaluation confirming need, training on device use, and a treatment plan specifying pressure, duration, and frequency. Ongoing monitoring is required.

    • Document practitioner evaluation and confirmation of medical need.
    • Provide and record training on device operation.
    • Specify prescribed pressure, treatment duration, and frequency.
    • Record ongoing monitoring.
    Documentation Required

    Safe Home Use and Treatment Response

    Before or during initial treatment, document clinical improvement, tolerance of therapy, and the member’s or caregiver’s ability to use the device safely at the prescribed frequency. Use under a qualified licensed practitioner is required.

    • Document improvement and response to treatment.
    • Confirm the therapy is tolerated.
    • Confirm that the member or caregiver can apply and operate the device safely as prescribed.
    Prior Authorization

    Prior Authorization Submission

    Submit the prior authorization request with all supporting clinical information required under the applicable MedStar Family Choice Prior Authorization Policy. An unsupported request may not be approved.

    • Include the diagnosis, objective findings, conservative-therapy history and outcomes, requested device and compressor type, treatment plan, and practitioner oversight documentation.
    • Attach documentation supporting the requested device’s medical necessity and any applicable E0652 criteria.
    Denial Risk

    Common Denial Conditions

    Requests may be denied when required conservative therapy is incomplete, the device is proposed as first-line treatment without justification, or the clinical record does not support medical necessity.

    • Conservative therapy was not completed or compression therapy was not attempted without documented contraindication.
    • The device is used as first-line therapy without justification.
    • Garments are improperly fitted or the patient is non-compliant.
    • Documentation is incomplete.
    • Therapy is not provided under a qualified licensed practitioner.

    Unsupported block type: denial_risk

    Denial Risk

    Advanced Device Documentation

    E0652 requires documented failure of E0650/E0651 and a clinical need for individualized pressure control. Confirm that the lymphedema extends onto the chest, trunk, or abdomen and that the requested system provides calibrated gradient pressure rather than pressure created only by sleeves or tubing.

    • Document the unique clinical factors requiring individualized pressure control.
    • Include the standard-device trial and its ineffective outcome.
    • Document lymphedema distribution involving the chest, trunk, or abdomen.
    • List compatible appliances when applicable: E0656, E0657, E0658, E0659, E0667, E0668, E0669, or E0670.
    No manual adjustment of pressure in individual compartments
    Segmented Pneumatic Compressor With Calibrated Gradient Pressure
    Compressor configurationMulti-chamber, segmented, programmable pump
    Adjustable portsManual pressure adjustment on at least 3 outflow ports
    Clinical functionDelivers individually determined pressure to corresponding garment segments