Loading...

    Explore
    • Policy Monitoring
    • Live Policy Feed
    • Billing Codes
    • Healthcare Providers
    • Health Insurance Payers
    • States
    • Service Lines
    • Taxonomy Codes
    Lookup tools
    • Billing Code Lookup
    • CPT Modifier Lookup
    • Provider Taxonomy Code Lookup
    • Healthcare Provider & Facility Lookup
    • Health Insurance Payer Lookup
    • Payer Contact Directory

    Policy & Benchmark Tools

    • Prior Authorization Lookup
    • Coverage Criteria Lookup
    • Timely Filing Lookup
    • Billing Code Reimbursement Rates
    • Payer Comparison Dashboard
    • Facility Comparison Dashboard
    • All tools

    Company

    • About OpenPayer
    • Data Sources
    • Request a Policy / Feedback
    • Trek Health
    OpenPayerby Trek Health
    LinkedInYouTube

    © 2026 Trek Health. All rights reserved.

    OpenPayer is built and maintained by Trek Health.

    v1.0.32
    OpenPayerPolicy UpdatesClinical/Medical PolicyMassachusetts EOHHS CardioMEMS Coverage | OpenPaye…
    Ask Trek AI about this page
    CurrentMassachusetts Executive Office of Health and Human ServicesPolicy N/A

    Guidelines for Medical Necessity Determination for CardioMEMS™

    Customize your policy alerts

    Sign up for all Massachusetts Executive Office of Health and Human Services policy alerts

    Know when Massachusetts Executive Office of Health and Human Services releases new policies or updates existing guidance.

    Monitor payer policy activity

    Receive email alerts as soon as relevant payer policies are published or updated.

    These guidelines describe the clinical information MassHealth uses to determine medical necessity and prior authorization for the CardioMEMS™ HF System, including its insertion procedure, implantable device, and sensor. They primarily address adults with NYHA class II or III heart failure and allow case-by-case review for other diagnoses.

    Policy Summary
    PayerMassachusetts Executive Office of Health and Human Services
    PolicyGuidelines for Medical Necessity Determination for CardioMEMS™
    Policy CodePolicy N/A
    Change TypeNo material clinical or coverage change
    Effective DateMay 13, 2022
    Next Review DateN/A
    Key ActionSubmit prior authorization electronically with supporting documentation before CardioMEMS™ implantation.
    SourceLink
    POLICY UPDATE CHANGES

    No material clinical or coverage changes in this revision.

    PA requiredPrior authorization
    1 yearMaximum coverage period
    1Insertion limit
    18+Minimum age

    OpenPayer is powered by Trek Health's payer performance platform. Trek continuously ingests, validates, and normalizes Transparency in Coverage data alongside payer policies and other commercial payer data to create a structured payer intelligence foundation. OpenPayer uses this foundation to deliver personalized search results, dynamically generated policy pages, and tailored policy monitoring based on each user's payers, specialties, billing codes, and areas of interest. The same intelligence powers broader payer performance workflows, including reimbursement benchmarking, contract evaluation, payer negotiations, and financial decision-making.

    II-III
    Covered NYHA classes
    NYHA INoncovered class

    Medical Necessity Criteria

    Heart Failure Coverage Criteria

    CardioMEMS™ may be considered medically necessary for heart failure with preserved or reduced ejection fraction when ALL of the following criteria are met and documented. Coverage of the system, including the insertion procedure, device, and sensor, is limited to up to one year from authorization, with no more than one insertion procedure during that one-year period.

    ALL of the following

    • The member has class II or class III heart failure under standards established by the New York Heart Association (NYHA).
    • ONE of the following

      • The member has experienced an acute inpatient hospital admission within the past 12 months, with heart failure as a diagnosis contributing to the admission.
      • The member has elevated natriuretic peptides within the past 30 days.
    • The member is not on a waiting list for a heart transplant.
    • There is no clinical concern for concurrent deep-vein thrombosis or pulmonary embolism.
    • The member is able to tolerate a course of dual antiplatelet therapy for one month following implantation of CardioMEMS™.
    • The member does not have a mechanical right-heart valve.
    • The member is 18 years of age or older.
    • The member has capacity to make fully informed decisions and has consented to the procedure after the limitations, risks, and complications have been discussed.
    • Comorbid medical or mental health disorders are appropriately managed and reasonably controlled.

    Additional Diagnoses

    Except as provided in the noncoverage circumstances below, CardioMEMS™ for a diagnosis other than heart failure may be considered only on a case-by-case basis based on documented medical necessity.

    ALL of the following

    • The diagnosis is other than heart failure.
    • Medical necessity is documented and supports case-by-case review.
    • None of the applicable noncoverage circumstances applies, including the circumstances described below.

    CardioMEMS™ is not medically necessary for members with class I heart failure under standards established by the New York Heart Association (NYHA).

    CardioMEMS™ is not medically necessary when there is a history or current risk of pulmonary embolism, or when the member has current deep-vein thrombosis (DVT).

    MassHealth does not consider CardioMEMS™ medically necessary under certain circumstances, including class I heart failure; a history or current risk of pulmonary embolism; current deep-vein thrombosis; renal failure requiring hemodialysis; a mechanical right-heart valve; or a history of severe bleeding.

    Authorization and Submission Requirements

    Prior Authorization

    Submit Prior Authorization Before Implantation

    Prior authorization is required before CardioMEMS™ implantation. The clinician performing the device implantation must electronically submit the PA request and all supporting documentation through the Provider Online Service Center (POSC), unless the provider has a currently approved electronic claims waiver.

    • Submit the request before implantation.
    • Waiver holders must submit the MassHealth PA-1 Form and all supporting documentation.
    Billing Rule

    Authorization Duration and Insertion Limit

    The CardioMEMS™ system, including the insertion procedure, device, and sensor, is covered for up to one year from the authorization date. Only one insertion procedure is allowed during that one-year period.

    CardioMEMS™ HF System Overview

    The CardioMEMS™ HF System is an implantable pulmonary artery pressure monitor placed in the left pulmonary artery during right-heart catheterization. Patients obtain daily readings using a home sensor, which transmits physiologic data wirelessly to clinicians for remote monitoring and identification of developing congestion so that clinicians can intervene.

    Clinical and Device Terms

    CardioMEMS™ HF System
    ManufacturerAbbott
    System componentsImplantable pulmonary artery pressure monitor, home sensor, and wireless physiologic-data transmission process
    Clinical useMonitors hemodynamic congestion in heart failure; the device is placed in the left pulmonary artery during right-heart catheterization
    MEMS
    AbbreviationMEMS
    MeaningMicroelectromechanical system
    Application in this policyThe CardioMEMS™ HF System uses an implantable pulmonary artery pressure monitor with home sensing and wireless data transmission
    Policy Summary
    PayerMassachusetts Executive Office of Health and Human Services
    PolicyGuidelines for Medical Necessity Determination for CardioMEMS™
    Policy CodePolicy N/A
    Change TypeNo material clinical or coverage change
    Effective DateMay 13, 2022
    Next Review DateN/A
    Key ActionSubmit prior authorization electronically with supporting documentation before CardioMEMS™ implantation.
    SourceLink
    On This Page
    Medical Necessity CriteriaAuthorization and Submission RequirementsCardioMEMS™ HF System OverviewClinical and Device Terms
    • Coverage period: up to one year from authorization.
    • Insertion limit: one procedure during the authorization period.
    Documentation Required

    Credentialed Clinical Assessment Required

    Include a copy of an assessment performed by an appropriately credentialed and enrolled provider in accordance with the guidelines. The assessment must support medical necessity and include the onset and history resulting in the relevant diagnosis, as well as referrals for the specific procedures.

    • Assessment must be performed by an appropriately credentialed and enrolled provider.
    • Include the date of onset and relevant diagnostic history.
    • Include referrals for the specific procedures.
    Documentation Required

    Document Co-morbidity Management

    Submit progress notes showing that the member’s co-existing medical or mental health diagnoses are appropriately managed and reasonably controlled.

    • Document management of co-existing medical conditions.
    • Document management of co-existing mental health conditions.
    • The conditions must be reasonably controlled.
    Documentation Required

    Proceduralist Attestation Required

    The clinician performing the procedure must submit a letter attesting that the member meets the Section II.A. clinical coverage criteria, that the clinician collaborated with other health care professionals involved in the member’s care, and that the risks and complications were discussed and informed consent was obtained.

    • Attest that all applicable clinical coverage criteria are met.
    • Attest to collaboration with involved health care professionals, including the primary care clinician when applicable.
    • Attest that risks and complications were discussed and informed consent was obtained.
    Denial Risk

    All Clinical Criteria Must Be Met

    CardioMEMS™ may be considered medically necessary only when all applicable clinical criteria are met and documented. Failure to satisfy any required criterion may result in denial of the PA request.

    • Required criteria include the applicable NYHA class, recent qualifying heart-failure hospitalization or elevated natriuretic peptides, eligibility and safety requirements, informed decision-making and consent, and appropriately managed co-morbid conditions.
    • Review and document every criterion before submitting the request.
    Denial Risk

    Noncovered Clinical Circumstances

    MassHealth does not consider CardioMEMS™ medically necessary in certain circumstances, including NYHA class I heart failure and heart failure with a history or current risk of pulmonary embolism. Other listed noncovered circumstances include current deep venous thrombosis, hemodialysis-dependent renal failure, a mechanical right-heart valve, or a history of severe bleeding.

    • NYHA class I heart failure is noncovered.
    • Pulmonary embolism history or current risk is noncovered.
    • Review related high-risk conditions before submission, including current deep venous thrombosis, hemodialysis-dependent renal failure, mechanical right-heart valve, and history of severe bleeding.
    Denial Risk

    Complete Supporting Documentation

    Missing or incomplete supporting documentation can delay review or result in denial. Ensure the PA request includes the credentialed clinical assessment, co-morbidity management records, proceduralist attestation, and documentation of informed consent.

    • Include the assessment with onset, diagnostic history, and relevant referrals.
    • Include progress notes showing co-existing conditions are appropriately managed and reasonably controlled.
    • Include the implanting clinician’s attestation and informed-consent documentation.
    HFpEF
    Full termHeart failure with preserved ejection fraction
    AbbreviationHFpEF
    Policy contextCardioMEMS™ may benefit certain patients with HFpEF, but is not beneficial for routine use
    HFrEF
    Full termHeart failure with reduced ejection fraction
    AbbreviationHFrEF
    Policy contextCardioMEMS™ may benefit certain patients with HFrEF; the guideline notes a mortality benefit for HFrEF
    NYHA heart failure class
    Full termNew York Heart Association functional classification
    Potentially eligible classesNYHA class II or class III heart failure
    Excluded classNYHA class I heart failure is not considered medically necessary for CardioMEMS™
    Clinical contextThe guideline states that CardioMEMS™ shows the most benefit in patients with class III heart failure