Loading...

    Explore
    • Policy Monitoring
    • Live Policy Feed
    • Billing Codes
    • Healthcare Providers
    • Health Insurance Payers
    • States
    • Service Lines
    • Taxonomy Codes
    Lookup tools
    • Billing Code Lookup
    • CPT Modifier Lookup
    • Provider Taxonomy Code Lookup
    • Healthcare Provider & Facility Lookup
    • Health Insurance Payer Lookup
    • Payer Contact Directory

    Policy & Benchmark Tools

    • Prior Authorization Lookup
    • Coverage Criteria Lookup
    • Timely Filing Lookup
    • Billing Code Reimbursement Rates
    • Payer Comparison Dashboard
    • Facility Comparison Dashboard
    • All tools

    Company

    • About OpenPayer
    • Data Sources
    • Trek Health
    OpenPayerby Trek Health
    LinkedInYouTube

    © 2026 Trek Health. All rights reserved.

    OpenPayer is built and maintained by Trek Health.

    v1.0.31
    OpenPayerPolicy UpdatesDurable Medical Equipment (DME)Upper Ohio Valley Exoskeleton Prior Auth | OpenPay…
    Ask Trek AI about this page
    DraftHealth Plan of the Upper Ohio ValleyPolicy 20464917

    Lower-Limb Robotic Exoskeleton for Ambulation

    Customize your policy alerts

    Sign up for healthplanofupperohiovalley Policy 20464917 alerts

    Get alerted when Policy 20464917 changes without checking for updates manually.

    Monitor payer policy activity

    Receive email alerts as soon as relevant payer policies are published or updated.

    Coverage, medical necessity, coding, documentation, and precertification requirements for powered lower-limb robotic exoskeletons, including ReWalk and Indego systems. Medicare coverage requires specified criteria; Commercial, Self-Funded, PEIA, and Medicaid coverage is excluded.

    Policy Summary
    PayerHealth Plan of the Upper Ohio Valley
    PolicyLower-Limb Robotic Exoskeleton for Ambulation
    Policy CodePolicy 20464917
    Change TypeNo material change
    Effective DateAugust 1, 2026
    Last ReviewJun 5, 2026
    Next Review DateJune 5, 2027
    Key ActionObtain a written, signed, and dated order before submitting a claim.
    SourceLink
    POLICY UPDATE CHANGES

    No material clinical or coverage changes in this revision.

    T7-L5Eligible spinal cord injury level
    3-6 monthsRequired device training

    OpenPayer is powered by Trek Health's payer performance platform. Trek continuously ingests, validates, and normalizes Transparency in Coverage data alongside payer policies and other commercial payer data to create a structured payer intelligence foundation. OpenPayer uses this foundation to deliver personalized search results, dynamically generated policy pages, and tailored policy monitoring based on each user's payers, specialties, billing codes, and areas of interest. The same intelligence powers broader payer performance workflows, including reimbursement benchmarking, contract evaluation, payer negotiations, and financial decision-making.

    K1007PDAC-approved code
    4 linesLines not covered
    2Approved products

    Coverage Criteria

    Medicare Initial Coverage Criteria

    Lower Limb Robotic Exoskeletons, specifically the ReWalk™ and Indego®, are covered for Medicare beneficiaries when ALL of the following criteria are met:

    ALL of the following

    • The member has a diagnosis of spinal cord injury (SCI) between thoracic level T7 and lumbar level L5 with paralysis.
    • The member has healthy bone density.
    • The member meets the physical requirements for operating the device, including adequate range of motion at the hips, knees, and ankles; intact upper-body sensation for crutch use; sufficient balance; and the capacity to perceive weight shifts.
    • The member has situational awareness and the cognitive ability to understand, learn, and manage the device's controls and safety protocols.
    • The member does not have severe neurological disorders, such as ALS or severe traumatic brain injury (TBI), that would contraindicate safe interaction with the device.
    • The member has completed 3–6 months of training.
    • The medical record documents the medical necessity criteria and is available upon precertification.

    Lower Limb Robotic Exoskeletons, including but not limited to the ReWalk™ and Indego®, are not covered for Commercial, Self-Funded, PEIA, or Medicaid lines of business because they are considered experimental and investigational. There is limited evidence in the published peer-reviewed scientific medical literature demonstrating the safety and efficacy of powered exoskeletons in the home or community setting.

    Neuromuscular electrical stimulation (NMES) provided to a member while in a hospital, rehabilitation, or skilled inpatient level of care will not be separately payable as durable medical equipment.

    Lower-limb robotic exoskeletons are considered experimental and investigational for Commercial, Self-Funded, PEIA, and Medicaid lines of business and are not covered at this time.

    Coding and Device Parameters

    Medicare contractor PDAC-approved HCPCS codeHCPCS
    K1007Bilateral hip, knee, ankle, foot device, powered, includes pelvic component, single or double upright(s), knee joints any type, with or without ankle joints any type, includes all components and accessories, motors, microprocessors, sensors.
    Spinal Cord Injury Level
    Eligible injury levelSpinal cord injury from thoracic level T7 through lumbar level L5 with paralysis
    Device Training
    Required trainingCompletion of 3–6 months of device training

    Provider Actions and Denial Risks

    Prior Authorization

    Precertification Required

    Suppliers must follow The Health Plan’s applicable precertification requirements before providing the device and must provide supporting documentation when requested for review.

    Documentation Required

    Medical Necessity Records

    The medical record must document the applicable medical-necessity criteria and be available upon precertification.

    • Documentation should support the beneficiary’s diagnosis, functional abilities, safety, cognitive capacity, and training completion.
    Documentation Required

    Treating Practitioner Documentation

    Device Background

    A lower-limb powered exoskeleton is a wearable, battery-powered robotic device intended to provide user-initiated mobility for individuals with spinal cord injuries or lower-limb disabilities. It may assist with standing, walking, and stair navigation in rehabilitation and home settings.

    Definitions

    Lower-Limb Exoskeleton
    StructureAn external structure with joints and links that may be regarded as a wearable robot designed around the shape and function of the human body
    Lower-Limb Powered Exoskeleton
    DefinitionA wearable, battery-powered robotic exoskeleton for individuals with spinal cord injuries or lower-limb disabilities that provides user-initiated mobility and enables standing, walking, and stair navigation in rehabilitation and home settings

    Medicare DME Medical Necessity

    Medicare DME Medical Necessity

    Medicare coverage requires ALL of the following clinical, functional, safety, and training criteria:

    Medical necessity for lower-limb robotic exoskeleton

    • Clinical criteria

      • Spinal cord injury: The beneficiary has a spinal cord injury between thoracic level T7 and lumbar level L5 with paralysis.T7-L5 with paralysis
      • Bone density: The beneficiary has healthy bone density.Healthy bone density
    • Functional operation criteria

    Documentation Requirements

    Billing Rule

    Obtain an equipment-specific order

    Obtain a written, signed, and dated order before submitting the claim. The order must identify the prescribed equipment.

    Documentation Required

    Prepare medical-necessity documentation

    Ensure that the treating practitioner provides thorough documentation substantiating medical necessity and appropriate use. Records must support the applicable criteria and be available for precertification review.

    Documentation Required

    Document noncovered-device notification

    Before dispensing a noncovered device, notify the member verbally and in writing that the specific service is not covered. Submit evidence of the notification upon request.

    Noncovered Services

    The following services and items are not covered: lower-limb robotic exoskeletons, including ReWalk and Indego systems, for Commercial, Self-Funded, PEIA, or Medicaid lines of business; and NMES provided in a hospital, rehabilitation, or skilled inpatient setting when billed separately as durable medical equipment.

    Policy Summary
    PayerHealth Plan of the Upper Ohio Valley
    PolicyLower-Limb Robotic Exoskeleton for Ambulation
    Policy CodePolicy 20464917
    Change TypeNo material change
    Effective DateAugust 1, 2026
    Last ReviewJun 5, 2026
    Next Review DateJune 5, 2027
    Key ActionObtain a written, signed, and dated order before submitting a claim.
    SourceLink
    On This Page
    Coverage CriteriaCoding and Device ParametersProvider Actions and Denial RisksDevice BackgroundDefinitionsMedicare DME Medical NecessityDocumentation RequirementsNoncovered Services

    The treating practitioner must provide thorough documentation substantiating medical necessity and appropriate use of the device.

    Billing Rule

    Written Order Required

    The supplier must obtain a written, signed, and dated order before submitting a claim to The Health Plan.

    Denial Risk

    Noncovered-Service Notification

    Before dispensing a noncovered item, the provider must notify the member verbally and in writing that the specific service is not covered. The provider should submit evidence of this notification upon request and may be held financially responsible if notification is not provided.

    Denial Risk

    Excluded Lines of Business

    Lower-limb robotic exoskeletons, including ReWalk and Indego, are not covered for Commercial, Self-Funded, PEIA, or Medicaid lines of business because they are considered experimental and investigational.

    • Limited peer-reviewed evidence demonstrates the safety and efficacy of powered exoskeletons in home or community settings.
    Denial Risk

    Medicare Criteria Must Be Met

    Medicare coverage is supported only when the required clinical, functional, safety, cognitive, and training criteria are met. Claims may be denied when the required spinal cord injury, bone-density, physical-function, situational-awareness, control-management, or training criteria are absent.

    • SCI must be between thoracic level T7 and lumbar level L5 with paralysis.
    • The member must have healthy bone density, adequate range of motion, intact upper-body sensation for crutch use, sufficient balance, and the ability to perceive weight shifts.
    • The member must have situational awareness and the cognitive ability to learn and manage device controls and safety protocols.
    • The member must complete 3–6 months of training.
    Denial Risk

    Contraindication or Unsafe Use

    Severe neurological disorders may contraindicate safe use of the device and preclude coverage.

    • Examples include amyotrophic lateral sclerosis (ALS) and severe traumatic brain injury (TBI), which may impair safe interaction with the device.
    Denial Risk

    Missing Order or Medical Records

    Claims may be denied when the required written order or medical-necessity records are missing or insufficient to substantiate the device’s medical necessity and appropriate use.

  1. Range of motion: The beneficiary has adequate range of motion at the hips, knees, and ankles.
  2. Upper-body sensation: The beneficiary has intact upper-body sensation for crutch use.
  3. Balance and weight-shift perception: The beneficiary has sufficient balance and the capacity to perceive weight shifts.
  4. Safety and cognitive criteria

    • Cognition and situational awareness: The beneficiary has situational awareness and the cognitive ability to understand, learn, and manage the device controls and safety protocols.
    • No specified contraindications: The beneficiary does not have severe neurologic disorders, such as ALS or severe traumatic brain injury, that could impair safe interaction with the device.Absence of specified severe neurologic disorders
  5. Training criterion: The beneficiary has completed device training.3–6 months