Loading...

    Explore
    • Policy Monitoring
    • Live Policy Feed
    • Billing Codes
    • Healthcare Providers
    • Health Insurance Payers
    • States
    • Service Lines
    • Taxonomy Codes
    Lookup tools
    • Billing Code Lookup
    • CPT Modifier Lookup
    • Provider Taxonomy Code Lookup
    • Healthcare Provider & Facility Lookup
    • Health Insurance Payer Lookup
    • Payer Contact Directory

    Policy & Benchmark Tools

    • Prior Authorization Lookup
    • Coverage Criteria Lookup
    • Timely Filing Lookup
    • Billing Code Reimbursement Rates
    • Payer Comparison Dashboard
    • Facility Comparison Dashboard
    • All tools

    Company

    • About OpenPayer
    • Data Sources
    • Request a Policy / Feedback
    • Trek Health
    OpenPayerby Trek Health
    LinkedInYouTube

    © 2026 Trek Health. All rights reserved.

    OpenPayer is built and maintained by Trek Health.

    v1.0.31
    OpenPayerPolicy UpdatesCardiologyHealth New England Cardiac Monitoring Update | Ope…
    Ask Trek AI about this page
    ModifiedHealth-New-EnglandPolicy UM375POL

    Ambulatory Electrocardiograph Monitoring - Medical Policy

    Customize your policy alerts

    Sign up for Health-New-England Policy UM375POL alerts

    Get alerted when Policy UM375POL changes without checking for updates manually.

    Monitor payer policy activity

    Receive email alerts as soon as relevant payer policies are published or updated.

    Governs medical necessity, prior authorization, coverage, and coding for external and implantable ambulatory ECG monitoring, including Holter, patch, mobile telemetry, external event, and implantable loop monitoring, across Commercial, Medicare Advantage, and Medicaid lines of business.

    Policy Summary
    PayerHealth-New-England
    PolicyAmbulatory Electrocardiograph Monitoring - Medical Policy
    Policy CodePolicy UM375POL
    Change TypeModified
    Effective DateAugust 1, 2026
    Next Review DateN/A
    Key ActionObtain prior authorization for implantable ambulatory ECG monitoring and related insertion or device-evaluation services.
    SourceLink
    POLICY UPDATE CHANGES

    The policy added CPT code 33285 for insertion of a subcutaneous cardiac rhythm monitor.

    The policy added remote programming and interrogation coding for subcutaneous cardiac rhythm monitor systems, including CPT 0650T.

    Prior authorization was removed for several external monitoring codes and for monitors of 30 days or fewer, except for specified mobile cardiac outpatient telemetry or loop-monitor circumstances.

    The policy added criteria for interrogation and analysis of an implanted ambulatory ECG monitoring device beyond three years after implantation.

    The policy removed the requirement for a non-diagnostic Holter monitor and removed the silent-myocardial-ischemia assessment criterion for individuals with documented coronary artery disease.

    OpenPayer is powered by Trek Health's payer performance platform. Trek continuously ingests, validates, and normalizes Transparency in Coverage data alongside payer policies and other commercial payer data to create a structured payer intelligence foundation. OpenPayer uses this foundation to deliver personalized search results, dynamically generated policy pages, and tailored policy monitoring based on each user's payers, specialties, billing codes, and areas of interest. The same intelligence powers broader payer performance workflows, including reimbursement benchmarking, contract evaluation, payer negotiations, and financial decision-making.

    5Codes requiring prior authorization
    17+External monitoring codes without prior authorization
    30 daysMCOT and external loop duration
    3 yearsRoutine implanted-device interrogation period
    >2/yearRepeated MCOT or external loop recordings

    Medical Necessity and Coverage Criteria

    Mobile cardiovascular outpatient telemetry

    MCOT is medically necessary when either criterion group is met.

    MCOT indications

    • Recurrent unexplained symptoms

      • The patient has recurrent unexplained syncope, presyncope, dizziness, or palpitations suspected to be caused by cardiac arrhythmia.
      • Symptoms occur less than daily.Less than daily
    • Suspected AF after brain infarction

      • Atrial fibrillation is suspected as the cause of a brain infarction.
      • The infarction is not attributed to a definite source of cardioembolism or large- or small-artery atherosclerosis.
      • The 48-hour Holter monitor is nondiagnostic.Nondiagnostic 48-hour Holter

    External cardiac event detection monitoring

    External cardiac event detection monitoring is medically necessary when either criterion group is met.

    External event-monitoring indications

    • Infrequent symptomatic events

      • Documentation confirms infrequent palpitations, dizziness, presyncope, or syncope.
      • Arrhythmia is unlikely to be diagnosed by a 24- or 48-hour Holter monitor.24- or 48-hour Holter insufficient
      • Testing will provide diagnostic or treatment information necessary for management beyond what would be provided by continuous 24- or 48-hour Holter monitoring.
    • AF/flutter burden assessment

    Implantable AECG monitoring

    Implantable AECG monitoring is medically necessary when any one of the following indications is met.

    Implantable AECG indications

    • Infrequent recurrent symptoms

      • The patient has recurrent unexplained syncope, presyncope, dizziness, or palpitations occurring so infrequently that a prior external AECG trial was unsuccessful.Prior unsuccessful 3-day Holter or 14-day monitor
    • Long-term AF/flutter monitoring

      • The patient requires long-term monitoring for atrial fibrillation or atrial flutter.
    • Possible AF/flutter after nondiagnostic evaluation

      • The patient has possible atrial fibrillation or flutter, such as cryptogenic stroke.

    Continuous external patch monitoring

    Long-term external patch ECG monitoring is medically necessary for the stated indication.

    External patch monitoring

    • The patient is suspected of having an arrhythmia.
    • Long-term external patch ECG monitoring uses continuous rhythm recording and storage.More than 48 hours up to 30 days

      Examples include Zio Patch and similar devices.

    Adult age-specific criteria

    Adults must meet one or more of the following age-specific criteria in addition to the applicable medical-necessity criteria above.

    Adult criteria

    • Evaluation of infrequent recurrent symptoms that may be associated with arrhythmia, such as presyncope, syncope, lightheadedness, palpitations, shortness of breath, chest pain, or dizziness.
    • Evaluation of unexplained recurrent palpitations after complete examination.
    • Monitoring after surgical or catheter ablation of atrial fibrillation when discontinuation of systemic anticoagulation is being considered.
    • Assessment of a history of cryptogenic stroke with evidence of prior nondiagnostic tests.
    • Evaluation of idiopathic hypertrophic or dilated cardiomyopathy to detect arrhythmias.

    Pediatric age-specific criteria

    Pediatric members must meet one or more of the following age-specific criteria in addition to the applicable medical-necessity criteria above.

    Pediatric criteria

    • Antiarrhythmic drug efficacy assessment during rapid somatic growth.
    • Asymptomatic congenital atrioventricular block that is non-paced.
    • Documented or potential long QT syndrome.
    • Hypertrophic or dilated cardiomyopathy.
    • Syncope, near-syncope, or sustained palpitations without a reasonable explanation and without overt clinical evidence of heart disease.

    Implantable AECG, MCOT, or external cardiac event detection monitoring performed in lieu of another monitoring method for the convenience of the patient, provider, or family is not medically necessary. These technologies should be requested when the applicable medical-necessity criteria support the selected monitoring method, rather than solely for convenience.

    Convenience-based use of implantable AECG, MCOT, or external cardiac event detection monitoring is not medically necessary. Monitoring requested for convenience instead of another appropriate monitoring method does not meet the policy’s coverage criteria.

    Covered Services and Code Guidance

    Covered CPT CodesCPTCovered
    93224External electrocardiographic recording up to 48 hours by continuous rhythm recording and storage; includes recording, scanning analysis with report, review and interpretation by a physician or other qualified health care professional.
    93225External electrocardiographic recording up to 48 hours by continuous rhythm recording and storage; recording (includes connection, recording, and disconnection).
    93226External electrocardiographic recording up to 48 hours by continuous rhythm recording and storage; scanning analysis with report.
    93227External electrocardiographic recording up to 48 hours by continuous rhythm recording and storage; review and interpretation by a physician or other qualified health care professional.
    Long-term 7-day and 14-day Monitoring CPT CodesCPT
    93241External electrocardiographic recording for more than 48 hours up to 7 days by continuous rhythm recording and storage; includes recording, scanning analysis with report, review and interpretation.
    93242External electrocardiographic recording for more than 48 hours up to 7 days by continuous rhythm recording and storage; recording (includes connection and initial recording).
    93243External electrocardiographic recording for more than 48 hours up to 7 days by continuous rhythm recording and storage; scanning analysis with report.
    93244External electrocardiographic recording for more than 48 hours up to 7 days by continuous rhythm recording and storage; review and interpretation.
    93245External electrocardiographic recording for more than 7 days up to 15 days by continuous rhythm recording and storage; includes recording, scanning analysis with report, review and interpretation.
    93246External electrocardiographic recording for more than 7 days up to 15 days by continuous rhythm recording and storage; recording (includes connection and initial recording).
    93247External electrocardiographic recording for more than 7 days up to 15 days by continuous rhythm recording and storage; scanning analysis with report.
    93248External electrocardiographic recording for more than 7 days up to 15 days by continuous rhythm recording and storage; review and interpretation.
    Covered CPT CodesCPTCovered
    93228Wearable mobile cardiovascular telemetry with electrocardiographic recording, concurrent computerized real time data analysis and greater than 24 hours of accessible ECG data storage, with ECG-triggered and patient-selected events transmitted to a remote attended surveillance center for up to 30 days; physician review and interpretation with report.
    93229Wearable mobile cardiovascular telemetry with electrocardiographic recording, concurrent computerized real time data analysis and greater than 24 hours of accessible ECG data storage, with technical support for connection and patient instructions for use, attended surveillance, analysis, and physician-prescribed transmission of daily and emergent data reports.
    Covered CPT CodesCPTCovered
    93268External cardiac event detection / external loop monitoring, up to 30 days; global service.
    93270External cardiac event detection / external loop monitoring; hookup.
    93271External cardiac event detection / external loop monitoring; technical service.
    93272External cardiac event detection / external loop monitoring; professional service.
    Covered CPT CodesCPTCovered
    33285Insertion, subcutaneous cardiac rhythm monitor, including programming.
    Covered CPT CodesCPTCovered
    93285In office device evaluation.
    93291In office device evaluation.
    93298Remote device evaluation.
    0650TRemote insertion of device evaluation.
    Codes Requiring Prior AuthorizationCPT
    33285Insertion, subcutaneous cardiac rhythm monitor, including programming.
    93285Programming device evaluation (in person) with iterative adjustment of the implantable device to test the function of the device and select optimal permanent programmed values with analysis, review and report by a physician or other qualified health care.
    93291Interrogation device evaluation (in person) with analysis, review and report by a physician or other qualified health care professional, includes connection, recording and disconnection per patient encounter; subcutaneous cardiac rhythm monitor system, including heart rhythm derived data analysis.
    93298Interrogation device evaluation(s), (remote) up to 30 days; subcutaneous cardiac rhythm monitor system, including analysis of recorded heart rhythm data, analysis, review(s) and report(s) by a physician or other qualified healthcare professional.
    0650TProgramming device evaluation (remote) of subcutaneous cardiac rhythm monitor system, with iterative adjustment of the implantable device to test the function of the device and select optimal permanently programmed values with analysis, review and report by a physician or other qualified health care professional.
    External Monitoring Codes Not Requiring Prior AuthorizationCPT
    93224External electrocardiographic recording up to 48 hours by continuous rhythm recording and storage; includes recording, scanning analysis with report, review and interpretation by a physician or other qualified health care professional.
    93225External electrocardiographic recording up to 48 hours by continuous rhythm recording and storage; recording (includes connection, recording, and disconnection).
    93226External electrocardiographic recording up to 48 hours by continuous rhythm recording and storage; scanning analysis with report.
    93227External electrocardiographic recording up to 48 hours by continuous rhythm recording and storage; review and interpretation by a physician or other qualified health care professional.
    93228Wearable mobile cardiovascular telemetry with electrocardiographic recording, concurrent computerized real time data analysis and greater than 24 hours of accessible ECG data storage (retrievable with query) with ECG triggered and patient selected events transmitted to a remote attended surveillance center for up to 30 days; physician review and interpretation with report.
    93229Wearable mobile cardiovascular telemetry with electrocardiographic recording, concurrent computerized real time data analysis and greater than 24 hours of accessible ECG data storage (retrievable with query) with ECG triggered and patient selected events transmitted to a remote attended surveillance center for up to 30 days; technical support for connection and patient instructions for use, attended surveillance, analysis.
    93241External electrocardiographic recording for more than 48 hours up to 7 days by continuous rhythm recording and storage; includes recording, scanning analysis with report, review and interpretation.
    93242External electrocardiographic recording for more than 48 hours up to 7 days by continuous rhythm recording and storage; recording (includes connection and initial recording).
    93243External electrocardiographic recording for more than 48 hours up to 7 days by continuous rhythm recording and storage; scanning analysis with report.
    93244External electrocardiographic recording for more than 48 hours up to 7 days by continuous rhythm recording and storage; review and interpretation.
    1–10 of 18
    1/2
    Holter monitoring
    Monitoring duration24–48 hours
    Recording methodContinuous rhythm recording and storage of all ECG data
    Service componentsRecording, scanning analysis with report, and physician or other qualified health care professional review and interpretation
    Continuous AECG patch monitoring
    Monitoring durationMore than 48 hours up to 30 days

    Prior Authorization and Documentation Requirements

    Prior Authorization

    Prior Authorization: Extended or Repeated External Monitoring

    Prior authorization is required for external ambulatory electrocardiograph (AECG) monitoring devices worn for more than 30 days and for repeated use exceeding two MCOT or external loop recordings in a calendar year.

    • External AECG monitoring over 30 days, including Mobile Cardiovascular Outpatient Telemetry (MCOT) and external loop recorders.
    • More than two MCOT or external loop recordings in one calendar year.
    Prior Authorization

    Prior Authorization: Implantable AECG Monitoring

    Prior authorization is required for patient-activated or auto-activated implantable AECG monitoring. Submit documentation showing the applicable medical-necessity indication.

    • Recurrent, infrequent unexplained syncope, presyncope, dizziness, or palpitations after an unsuccessful 3-day Holter or 14-day external monitor.
    • Long-term monitoring for atrial fibrillation or atrial flutter.
    • Possible atrial fibrillation or flutter, including cryptogenic stroke with nondiagnostic prior external monitoring and no identified source of cardioembolism or arterial atherosclerosis.

    Ambulatory ECG Monitoring Overview

    Ambulatory ECG monitoring records cardiac electrical activity during routine activity and periods of stress for longer than a standard 10-second ECG. It is used primarily to evaluate intermittent or asymptomatic arrhythmias and conduction abnormalities, with monitoring duration selected according to symptom frequency and the monitoring method. Available methods range from continuous 24–48-hour Holter monitoring to external or implantable monitoring for longer periods, including up to 30 days for certain external monitors.

    Monitoring and Diagnostic Terms

    Holter monitoring
    DefinitionHolter monitoring continuously records all ECG data
    Recording duration24–48 hours
    Service scopeExternal electrocardiographic recording by continuous rhythm recording and storage
    Continuous AECG patch monitoring
    DefinitionContinuous ambulatory ECG patch monitoring using a single-use AECG monitor
    DurationUsed for periods longer than 2 days
    Data collectionListed devices can collect all rhythm data for up to 14 days
    Policy Summary
    PayerHealth-New-England
    PolicyAmbulatory Electrocardiograph Monitoring - Medical Policy
    Policy CodePolicy UM375POL
    Change TypeModified
    Effective DateAugust 1, 2026
    Next Review DateN/A
    Key ActionObtain prior authorization for implantable ambulatory ECG monitoring and related insertion or device-evaluation services.
    SourceLink
    On This Page
    Medical Necessity and Coverage CriteriaCovered Services and Code GuidancePrior Authorization and Documentation RequirementsAmbulatory ECG Monitoring OverviewMonitoring and Diagnostic Terms
    The member has a history of atrial fibrillation or atrial flutter.
  1. Monitoring is needed to assess atrial fibrillation/flutter burden to inform medical decisions such as rate control or anticoagulation.
  2. No definitive source of cardioembolism, large-artery atherosclerosis, or small-artery atherosclerosis has been identified.
  3. External cardiac monitoring was nondiagnostic, including a 24–48-hour Holter, telemetry, or long-term external AECG.Nondiagnostic external monitoring
  4. Palpitations after surgery for congenital heart disease with significant residual hemodynamic abnormalities.
  5. Previously documented arrhythmia or pacemaker dependency.
  6. Syncope or near-syncope associated with exertion, or dizziness with known heart disease.
  7. Recording methodContinuous ambulatory ECG recording and storage
    Listed device capabilityDevices can collect all rhythm data for up to 14 days
    MCOT and external loop monitoring
    Monitoring durationUp to 30 days
    Monitoring typeExternal cardiac event detection or external loop monitoring
    Event recordingGenerally stores 30 seconds to 2 minutes before and after a patient- or auto-triggered event
    Repeated MCOT or external loop recordings
    Prior authorization thresholdMore than 2 MCOT or external loop recordings in 1 calendar year
    Applies toMCOT and external loop recordings
    Policy requirementPrior authorization is required when the threshold is exceeded
    Prior Authorization

    Prior Authorization: Implant and Device Evaluation Services

    Obtain prior authorization for implantable AECG insertion and related device-evaluation services when the device meets the policy’s medical-necessity criteria.

    • In-person programming or interrogation: CPT 93285 and 93291.
    • Remote interrogation or programming evaluation: CPT 93298 and 0650T.
    Prior Authorization

    Prior Authorization: Subcutaneous Monitor Insertion

    Prior authorization is required for insertion of a subcutaneous cardiac rhythm monitor, including programming.

    • CPT 33285 — insertion, subcutaneous cardiac rhythm monitor, including programming.
    Prior Authorization

    Prior Authorization: Implantable Monitor Evaluation

    Prior authorization is required for evaluation of a medically necessary implanted AECG monitoring device, including in-person programming or interrogation and remote interrogation or programming evaluation.

    • CPT 93285 — in-person programming device evaluation.
    • CPT 93291 — in-person interrogation device evaluation.
    • CPT 93298 — remote interrogation up to 30 days.
    • CPT 0650T — remote programming device evaluation.
    Documentation Required

    Document the Need for External Event Monitoring

    For external event-detection monitoring, document the symptoms, their frequency, the suspected arrhythmia, and why a shorter Holter monitor is unlikely to establish the diagnosis or provide sufficient management information.

    • Document symptoms such as palpitations, dizziness, presyncope, or syncope.
    • State that symptoms occur infrequently and are unlikely to be diagnosed by a 24- or 48-hour Holter monitor.
    • Explain how the requested monitoring will provide diagnostic or treatment information beyond continuous Holter monitoring.
    • For atrial fibrillation or flutter, document the need to assess arrhythmia burden for decisions such as rate control or anticoagulation.
    Documentation Required

    Document the Clinical Indication

    Document the relevant clinical indication and supporting history for the requested monitoring service, including symptoms, suspected arrhythmia, prior nondiagnostic testing, and applicable arrhythmia or cardiac conditions.

    • Adults: infrequent recurrent symptoms, unexplained recurrent palpitations, post-ablation atrial-fibrillation monitoring when anticoagulation discontinuation is considered, cryptogenic stroke with prior nondiagnostic testing, or idiopathic hypertrophic or dilated cardiomyopathy.
    • Pediatric indications: antiarrhythmic drug efficacy during rapid growth; asymptomatic congenital non-paced atrioventricular block; documented or potential long-QT syndrome; hypertrophic or dilated cardiomyopathy; unexplained syncope, near-syncope, or sustained palpitations; post-congenital-heart-surgery palpitations with significant residual abnormalities; documented arrhythmia or pacemaker dependency; or exertional syncope, near-syncope, or dizziness with known heart disease.
    • For MCOT, document suspected cardiac arrhythmia with symptoms occurring less than daily, or suspected atrial fibrillation after brain infarction with a nondiagnostic 48-hour Holter monitor.
    Documentation Required

    Documentation Beyond Three Years

    For implanted AECG interrogation and analysis beyond three years after implantation, provide clinical documentation supporting ongoing medical necessity.

    • Coverage is limited to medically necessary implanted AECG devices that met the applicable criteria.
    • Interrogation and analysis may be performed once every 30 days when ongoing medical necessity is documented.
    Documentation Required

    Submit Clinical Evidence

    The treating physician or primary care provider must submit clinical evidence showing that the patient meets the criteria for the requested treatment, testing, or procedure.

    • Include relevant clinical notes, symptom history, prior monitoring results, diagnoses, and the rationale for the requested service.
    • Submit sufficient information for Health New England to complete the prior-authorization review.
    Denial Risk

    Convenience Use Is Not Medically Necessary

    Implantable AECG monitoring used in lieu of another monitoring method for the convenience of the patient, provider, or family is not medically necessary.

    • Document why the requested implantable monitor is clinically indicated rather than selected for convenience.
    Denial Risk

    Convenience Use of External Monitoring

    MCOT or external cardiac event detection monitoring used in lieu of another monitoring method for the convenience of the patient, provider, or family is not medically necessary.

    • The request must be supported by the applicable symptom pattern, suspected arrhythmia, and diagnostic or treatment need.
    Denial Risk

    Use Outside Medical-Necessity Criteria

    Implantable AECG monitoring, MCOT, or external cardiac event detection monitoring that does not meet the policy’s stated medical-necessity criteria is considered experimental and investigational.

    • For implantable AECG, all other uses are experimental and investigational.
    • For MCOT or external event detection, uses outside the stated criteria are experimental and investigational.
    Denial Risk

    Self-Monitoring ECG Technology

    Self-monitoring ECG technologies, including Kardia Mobile, are considered experimental and investigational under this policy.

    • Do not request coverage as medically necessary based solely on use of a self-monitoring ECG technology.
    Documentation Required

    Insufficient Clinical Documentation

    Requests may not be properly reviewed without clinical evidence demonstrating that the patient meets the applicable criteria.

    • The treating physician or primary care provider must submit the required documentation with the prior-authorization request.
    • Missing information may prevent Health New England from determining whether the requested service is medically necessary.
    External cardiac event detection monitoring
    DefinitionAn external loop monitor capable of monitoring an individual for long durations
    Monitoring durationUp to 30 days
    Event storage and transmissionGenerally stores 30 seconds to 2 minutes before and after a patient- or auto-triggered event, then transmits the recording to an attended surveillance center
    Implantable loop monitor/recorder
    DefinitionA single-lead ECG monitoring device implanted directly under the skin
    Diagnostic useUsed to diagnose recurrent unexplained episodes of palpitations or syncope
    Insertion guidanceRarely the preferred initial ambulatory ECG test; an electrophysiological study is not a prerequisite for insertion
    Mobile cardiac outpatient telemetry
    DefinitionAn automatic, continuous real-time cardiac monitor that requires no patient activation
    Monitoring durationUp to 30 days
    Transmission behaviorAutomatically transmits arrhythmia ECG segments to an attended surveillance center and can capture events when the patient has no symptoms
    Electrophysiology study
    Test settingPerformed in an electrophysiology laboratory or cardiac catheterization laboratory
    Test methodA thin catheter containing electrodes is inserted into a blood vessel leading to the heart to record electrical activity
    Clinical purposeIdentifies the origin of an abnormal rhythm and may evaluate medication effectiveness, cardiac-arrest risk, or treatment options