Loading...

    Explore
    • Policy Monitoring
    • Live Policy Feed
    • Billing Codes
    • Healthcare Providers
    • Health Insurance Payers
    • States
    • Service Lines
    • Taxonomy Codes
    Lookup tools
    • Billing Code Lookup
    • CPT Modifier Lookup
    • Provider Taxonomy Code Lookup
    • Healthcare Provider & Facility Lookup
    • Health Insurance Payer Lookup
    • Payer Contact Directory

    Policy & Benchmark Tools

    • Prior Authorization Lookup
    • Coverage Criteria Lookup
    • Timely Filing Lookup
    • Billing Code Reimbursement Rates
    • Payer Comparison Dashboard
    • Facility Comparison Dashboard
    • All tools

    Company

    • About OpenPayer
    • Data Sources
    • Request a Policy / Feedback
    • Trek Health
    OpenPayerby Trek Health
    LinkedInYouTube

    © 2026 Trek Health. All rights reserved.

    OpenPayer is built and maintained by Trek Health.

    v1.0.32
    OpenPayerPolicy UpdatesEndocrinologyHealth Choice Arizona Insulin Pump Coverage | Open…
    Ask Trek AI about this page
    CurrentHealth Choice ArizonaPolicy P003.7

    External Insulin Pumps and System Components

    Customize your policy alerts

    Sign up for health_choice_arizona Policy P003.7 alerts

    Get alerted when Policy P003.7 changes without checking for updates manually.

    Monitor payer policy activity

    Receive email alerts as soon as relevant payer policies are published or updated.

    Coverage and medical-necessity criteria for specified external insulin pumps and system components, including initial therapy, continuation, replacement, and renewals for members with type 1 or type 2 diabetes in Commercial and Marketplace plans.

    Policy Summary
    PayerHealth Choice Arizona
    PolicyExternal Insulin Pumps and System Components
    Policy CodePolicy P003.7
    Change TypeNo material clinical or coverage changes
    Effective DateN/A
    Last ReviewFeb 16, 2023
    Next Review DateN/A
    Key ActionSubmit the completed precertification request form with required clinical documentation and the prescribing provider’s signature.
    SourceLink
    POLICY UPDATE CHANGES

    No material clinical or coverage changes in this revision.

    3+ monthsPre-initiation insulin treatment
    4 times/day

    OpenPayer is powered by Trek Health's payer performance platform. Trek continuously ingests, validates, and normalizes Transparency in Coverage data alongside payer policies and other commercial payer data to create a structured payer intelligence foundation. OpenPayer uses this foundation to deliver personalized search results, dynamically generated policy pages, and tailored policy monitoring based on each user's payers, specialties, billing codes, and areas of interest. The same intelligence powers broader payer performance workflows, including reimbursement benchmarking, contract evaluation, payer negotiations, and financial decision-making.

    Required glucose monitoring
    3 of 5Required response measures
    12 monthsApproval and renewal duration
    >220 units/dayType 2 daily insulin threshold
    8HCPCS codes listed

    Medical Necessity and Coverage Criteria

    Type 1 diabetes initial therapy

    Covered for type 1 diabetes initial therapy when ALL criteria are met, including ONE qualifying device-age criterion.

    Type 1 initial therapy

    • Provider and diagnosis

      • Provider qualification: The prescriber is a physician or other prescriber specializing in diabetes or is in consultation with an Endocrinologist.
      • Diagnosis: The individual has a confirmed diagnosis of type 1 diabetes mellitus.
    • ONE qualifying device-age criterion

      • Device-specific minimum age

        • Omnipod Dash: The individual is 2 years of age or older.
        • Omnipod: The individual is an adult or child.
        • Omnipod 5 G6: The individual is 6 years of age or older.
        • MiniMed 630G System: The individual is 14 years of age or older.
        • MiniMed 670G System: The individual is 7 years of age or older.
        • MiniMed 770G System: The individual is 2 years of age or older.
        • T:Slim X2: The individual is 6 years of age or older.
    • Treatment preparation

      • Diabetes education: There is evidence the individual has completed a diabetes self-management education program.
      • Insulin injections and dose adjustment: The treatment program includes at least three insulin injections per day with frequent self-adjustments of insulin dose for at least three months.At least 3 injections per day for at least 3 months
      • Glucose monitoring: There is documentation of blood glucose self-testing averaging at least four times per day or documented use of a therapeutic factory-calibrated CGM during the two months before initiation of an insulin pump.At least 4 glucose checks per day or therapeutic factory-calibrated CGM during the preceding 2 months

    Omnipod continuation therapy

    Covered for continuation of Omnipod therapy when ALL ongoing-care requirements are met and THREE response measures are present.

    • Ongoing diabetes-specialist care: The individual continues to be seen by a physician or other prescriber specializing in diabetes or is in consultation with an Endocrinologist.
    • THREE clinical response measures

      • The individual has achieved and maintains an HbA1c of 7% or less, or 8% or less if age 65 or older.
      • There has been a reduction in recurrent, unexplained, unexpected hypoglycemic episodes.
      • There is no hypoglycemia unawareness.

    Type 2 diabetes initial therapy

    Covered for type 2 diabetes initial therapy when ALL criteria are met, including ONE qualifying device-age criterion.

    Type 2 initial therapy

    • Provider and diagnosis

      • Provider qualification: The prescriber is a physician or other prescriber specializing in diabetes or is in consultation with an Endocrinologist.
      • Diagnosis: The individual has a confirmed diagnosis of type 2 diabetes mellitus.
    • ONE qualifying device-age criterion

      • MiniMed 630G System: The individual is 14 years of age or older.

    Replacement of pump or system component

    Replacement of an external insulin pump or delivery component is covered when ALL replacement criteria are met; type 2 diabetes additionally requires THREE response measures.

    External pump or system component replacement

    • Successfully managed diabetes: The individual has successfully managed diabetes mellitus.
    • Malfunction and repair status: The pump or component is malfunctioning, cannot be repaired, and is no longer under warranty.
    • Endocrinology evaluation: An endocrinologist managing the diabetes evaluated the individual within the last six months and recommends continued use of a replacement device.Evaluation within the last 6 months
    • Diabetes type

    Experimental or investigational use

    Pump therapy is considered experimental or investigational when ANY of the following conditions applies.

    • The insulin pump lacks final approval from the appropriate governmental regulatory bodies, such as the Food and Drug Administration.
    • Scientific evidence is insufficient to permit conclusions concerning the effect on health outcomes.
    • Evidence is insufficient to support improvement of the net health outcome.
    • Evidence is insufficient to support improvement of the net health outcome as much as, or more than, established alternatives.
    • Evidence is insufficient to support improvement outside the investigational setting.

    Replacing a currently functioning insulin pump solely to obtain the most recent or improved technology is considered a convenience item and is not medically necessary.

    Additional software or hardware required to download insulin-pump data to a personal computer, smartphone, or tablet for diabetes self-management is considered a convenience item and is not medically necessary.

    Pump upgrades intended only to obtain improved technology, as well as data-download software or hardware used for diabetes self-management, are convenience items and are not medically necessary.

    Coding and Operational Parameters

    HCPCSHCPCS
    A9274
    A4226
    E0784
    E0787
    S1034
    S1035
    S1036
    S1037
    Pre-initiation insulin injections
    Minimum injectionsAt least 3 insulin injections per day
    Dose managementFrequent self-adjustments of insulin dose
    Required durationAt least 3 months before pump initiation
    Pre-initiation glucose monitoring
    Self-testing frequencyAverage blood glucose self-testing at least 4 times per day
    Alternative monitoringTherapeutic factory-calibrated CGM use may be documented instead
    Monitoring period

    Authorization and Documentation Requirements

    Prior Authorization

    Prior Authorization Required

    Precertification is required for insulin pump requests. Prior authorization is also required for Omnipod pods before dispensing.

    • Submit the request through the applicable pharmacy benefit authorization process.
    Documentation Required

    Precertification Submission

    The precertification submission must be complete and signed by the prescribing provider. Incomplete submissions may delay the coverage determination.

    • Completed request form
    • Chart notes
    • Laboratory workup
    • Any other supporting documentation
    • Fax to BCBSAZ Pharmacy Management at (602) 864-3126 or email Pharmacyprecert@azblue.com

    Guideline Scope and Covered Devices

    This guideline addresses coverage of external insulin pump therapy for individuals with type 1 or type 2 diabetes mellitus. It includes specified Omnipod, Medtronic MiniMed, and Tandem devices and addresses initial therapy, continued therapy, replacement of an external pump, and replacement of pump or delivery-system components.

    Initial therapy requires intensive insulin management, diabetes self-management education, and frequent glucose monitoring. For type 2 diabetes, coverage also requires elevated HbA1c despite multi-regimen treatment and a high daily insulin requirement. Continued therapy is evaluated using documented glycemic and complication-related response measures.

    Policy Summary
    PayerHealth Choice Arizona
    PolicyExternal Insulin Pumps and System Components
    Policy CodePolicy P003.7
    Change TypeNo material clinical or coverage changes
    Effective DateN/A
    Last ReviewFeb 16, 2023
    Next Review DateN/A
    Key ActionSubmit the completed precertification request form with required clinical documentation and the prescribing provider’s signature.
    SourceLink
    On This Page
    Medical Necessity and Coverage CriteriaCoding and Operational ParametersAuthorization and Documentation RequirementsGuideline Scope and Covered Devices
    There is no post-prandial hyperglycemia.
  1. There has been a reduction in diabetic ketoacidosis.
  2. MiniMed 670G System: The individual is 7 years of age or older.
  3. MiniMed 770G System: The individual is 2 years of age or older.
  4. T:Slim X2: The individual is 6 years of age or older.
  5. Type 2 clinical requirements

    • The individual has an HbA1c greater than 7% on two consecutive HbA1c tests.HbA1c >7% on 2 consecutive tests
    • The individual is currently receiving multi-regimen diabetes treatment including GLP-1 and SGLT-2 therapy.
    • The individual is using greater than 220 units of insulin per day.>220 units of insulin per day
    • There is evidence the individual has completed a diabetes self-management education program.
    • The treatment program includes at least three insulin injections per day with frequent self-adjustments of insulin dose for at least three months.At least 3 injections per day for at least 3 months
    • There is documentation of blood glucose self-testing averaging at least four times per day or documented use of a therapeutic factory-calibrated CGM during the two months before initiation of an insulin pump.At least 4 glucose checks per day or therapeutic factory-calibrated CGM during the preceding 2 months
  6. Type 1 diabetes: The replacement request is for an individual with type 1 diabetes mellitus.
  7. Type 2 diabetes

    • THREE clinical response measures

      • The individual has achieved and maintains an HbA1c of 7% or less, or 8% or less if age 65 or older.
      • There has been a reduction in recurrent, unexplained, unexpected hypoglycemic episodes.
      • There is no hypoglycemia unawareness.
      • There is no post-prandial hyperglycemia.
      • There has been a reduction in diabetic ketoacidosis.
  8. The treatment uses dosing, frequency, or duration outside FDA-approved dosing, frequency, and duration.
    During the 2 months before initiation of an insulin pump
    Type 2 HbA1c
    HbA1c thresholdGreater than 7%
    Required results2 consecutive HbA1c tests
    Applicable therapyType 2 diabetes initial pump therapy
    Type 2 daily insulin requirement
    Daily insulin thresholdGreater than 220 units per day
    MeasurementCurrent insulin use
    Applicable therapyType 2 diabetes initial pump therapy
    Response for continuation or type 2 replacement
    Required responseAt least 3 of 5 response measures
    Glycemic responseAchieved and maintains HbA1c of 7% or less, or 8% or less for individuals age 65 and older
    Additional response measuresReduction in recurrent unexplained unexpected hypoglycemic episodes; no hypoglycemia unawareness; no post-prandial hyperglycemia; or reduction in diabetic ketoacidosis
    Replacement endocrinology evaluation
    Evaluation timingWithin the last 6 months
    EvaluatorAn endocrinologist managing the diabetes
    Required documentationEvaluation includes a recommendation supporting continued use of a replacement device
    Approval and renewal duration
    Authorization period12 months
    Omnipod approval duration12 months
    Renewal duration12 months
    Documentation Required

    Type 1 Initial Therapy Records

    For initial insulin pump therapy in type 1 diabetes, submit medical records showing that all requirements are met.

    • Prescriber specializes in diabetes or is consulting with an endocrinologist
    • Confirmed diagnosis of type 1 diabetes mellitus
    • Age meets the applicable device requirement: Omnipod Dash ≥2 years; Omnipod, adults and children; Omnipod 5 G6 ≥6 years; MiniMed 630G ≥14 years; MiniMed 670G ≥7 years; MiniMed 770G ≥2 years; or T:Slim X2 ≥6 years
    • Completed diabetes self-management education program
    • At least three insulin injections daily with frequent insulin-dose self-adjustments for at least three months
    • Blood-glucose self-testing averaging at least four times daily, or use of a therapeutic factory-calibrated CGM, during the two months before pump initiation
    Documentation Required

    Continuation Records

    For continuation or renewal of an Omnipod pump for type 1 diabetes, document ongoing specialist management and clinical response to therapy.

    • Continued care by a physician or other prescriber specializing in diabetes, or consultation with an endocrinologist
    • At least three response measures: maintained HbA1c ≤7% (or ≤8% for individuals age 65 or older); reduced recurrent unexplained or unexpected hypoglycemic episodes; no hypoglycemia unawareness; no post-prandial hyperglycemia; or reduced diabetic ketoacidosis
    Documentation Required

    Type 2 Initial Therapy Records

    For initial insulin pump therapy in type 2 diabetes, submit medical records showing that all requirements are met.

    • Prescriber specializes in diabetes or is consulting with an endocrinologist
    • Confirmed diagnosis of type 2 diabetes mellitus
    • Age meets the applicable device requirement: MiniMed 630G ≥14 years; MiniMed 670G ≥7 years; MiniMed 770G ≥2 years; or T:Slim X2 ≥6 years
    • HbA1c greater than 7% on two consecutive HbA1c tests
    • Currently receiving multi-regimen diabetes treatment that includes a GLP-1 and an SGLT-2 agent
    • Using more than 220 units of insulin per day
    • Completed diabetes self-management education program
    • At least three insulin injections daily with frequent insulin-dose self-adjustments for at least three months
    • Blood-glucose self-testing averaging at least four times daily, or use of a therapeutic factory-calibrated CGM, during the two months before pump initiation
    • Initial approval duration is 12 months
    Documentation Required

    Replacement Records

    For replacement of an external insulin pump or insulin-delivery system component, document that the existing equipment cannot continue to be used and that replacement remains clinically appropriate. For type 2 diabetes, also document the required response to therapy.

    • Pump or component is malfunctioning, cannot be repaired, and is no longer under warranty
    • Endocrinologist managing the diabetes evaluated the individual within the last six months and recommended continued use of a replacement device
    • For type 2 diabetes, document at least three response measures: maintained HbA1c ≤7% (or ≤8% for individuals age 65 or older); reduced recurrent unexplained or unexpected hypoglycemic episodes; no hypoglycemia unawareness; no post-prandial hyperglycemia; or reduced diabetic ketoacidosis

    Unsupported block type: denial_risk

    Denial Risk

    Unapproved or Investigational Use

    Insulin pump treatment is considered experimental or investigational when it lacks required regulatory approval or sufficient evidence of improved health outcomes, including evidence comparable to established alternatives or outside the investigational setting. Use outside FDA-approved dosing, frequency, duration, device, or indication may result in denial.

    • Review the applicable off-label-use policy for use outside FDA-approved guidelines.
    • Document the FDA-approved indication and applicable dosing, frequency, and duration.
    Denial Risk

    Technology Upgrade Only

    Replacing a currently functioning insulin pump solely to obtain newer or improved technology is a convenience item and is not medically necessary.

    • Do not submit a technology upgrade as a medically necessary replacement when the current pump is functioning.
    Denial Risk

    Data-Download Accessories

    Additional software or hardware needed to download pump data to a personal computer, smartphone, tablet, or similar device for diabetes self-management is a convenience item and is not medically necessary.

    • Data-download accessories are not eligible as medically necessary insulin pump equipment.
    Denial Risk

    Replacement Eligibility Not Established

    Replacement eligibility is not established unless the request includes documentation of the pump or component's malfunction, inability to be repaired, and end-of-warranty status, together with the required endocrinology evaluation.

    • Include all replacement-eligibility records before submitting the request.
    • The endocrinologist's evaluation must be within the six months preceding the request and support continued use of a replacement device.