Loading...

    Explore
    • Policy Monitoring
    • Live Policy Feed
    • Billing Codes
    • Healthcare Providers
    • Health Insurance Payers
    • States
    • Service Lines
    • Taxonomy Codes
    Lookup tools
    • Billing Code Lookup
    • CPT Modifier Lookup
    • Provider Taxonomy Code Lookup
    • Healthcare Provider & Facility Lookup
    • Health Insurance Payer Lookup
    • Payer Contact Directory

    Policy & Benchmark Tools

    • Prior Authorization Lookup
    • Coverage Criteria Lookup
    • Timely Filing Lookup
    • Billing Code Reimbursement Rates
    • Payer Comparison Dashboard
    • Facility Comparison Dashboard
    • All tools

    Company

    • About OpenPayer
    • Data Sources
    • Request a Policy / Feedback
    • Trek Health
    OpenPayerby Trek Health
    LinkedInYouTube

    © 2026 Trek Health. All rights reserved.

    OpenPayer is built and maintained by Trek Health.

    v1.0.32
    OpenPayerPolicy UpdatesWound CareFallon Health Hyperbaric Coverage | OpenPayer
    Ask Trek AI about this page
    CurrentFallon Community Health Plan IncPolicy N/A

    Hyperbaric Oxygen Therapy Clinical Coverage Criteria

    Customize your policy alerts

    Sign up for all fallon_community_health_plan_inc policy alerts

    Know when fallon_community_health_plan_inc releases new policies or updates existing guidance.

    Monitor payer policy activity

    Receive email alerts as soon as relevant payer policies are published or updated.

    This policy governs coverage, medical-necessity review, prior authorization, exclusions, and billing guidance for hyperbaric oxygen therapy across Fallon Health products, including Medicare, MassHealth, Community Care, pediatric, emergency, and post-stabilization services.

    Policy Summary
    PayerFallon Community Health Plan Inc
    PolicyHyperbaric Oxygen Therapy Clinical Coverage Criteria
    Policy CodePolicy N/A
    Change TypeAnnual review — no material clinical or coverage changes
    Effective DateSeptember 1, 2026
    Last ReviewAug 18, 2026
    Next Review DateN/A
    Key ActionObtain prior authorization for non-emergent hyperbaric oxygen therapy and for post-stabilization treatment after an emergency.
    SourceLink
    POLICY UPDATE CHANGES

    Pediatric InterQual subset retired; no coverage criteria changes.

    Annual review approved with no changes to coverage criteria.

    ≥2.0 ATATypical chamber pressure
    90–120 minTypical session duration
    30 daysDiabetic-wound reassessment threshold

    OpenPayer is powered by Trek Health's payer performance platform. Trek continuously ingests, validates, and normalizes Transparency in Coverage data alongside payer policies and other commercial payer data to create a structured payer intelligence foundation. OpenPayer uses this foundation to deliver personalized search results, dynamically generated policy pages, and tailored policy monitoring based on each user's payers, specialties, billing codes, and areas of interest. The same intelligence powers broader payer performance workflows, including reimbursement benchmarking, contract evaluation, payer negotiations, and financial decision-making.

    Wagner III+
    Required diabetic wound severity
    16 minAdditional billing-unit threshold

    Covered Services and Exclusions

    Covered conditions

    Covered when treatment is administered in a chamber and the indication is one of the following:

    Covered indications

    • Covered conditions: Acute carbon monoxide intoxication; decompression illness; gas embolism; gas gangrene; acute traumatic peripheral ischemia when loss of function, limb, or life is threatened; crush injuries and suturing of severed limbs when loss of function, limb, or life is threatened; progressive necrotizing infections, including necrotizing fasciitis; acute peripheral arterial insufficiency; preparation and preservation of compromised skin grafts, not for primary wound management; chronic refractory osteomyelitis unresponsive to conventional medical and surgical management; osteoradionecrosis as an adjunct to conventional treatment; soft tissue radionecrosis as an adjunct to conventional treatment; cyanide poisoning; actinomycosis refractory to antibiotics and surgical treatment, as an adjunct to conventional therapy.

      Where described as adjunctive, HBOT must be used with accepted conventional treatment.

    • Qualifying diabetic lower-extremity wound

      • The patient has type I or type II diabetes and a lower-extremity wound due to diabetes.
      • The wound is classified as Wagner grade III or higher.Wagner grade III or higher
      • The patient has failed an adequate course of standard wound therapy, with no measurable signs of healing for at least 30 consecutive days.No measurable signs of healing for at least 30 consecutive days

        HBOT is adjunctive only and must be used in addition to standard wound care, including vascular assessment and correction when possible, nutritional and glucose optimization, debridement, maintenance of a clean moist granulation bed with appropriate dressings, offloading, and treatment of infection.

    Continuation of diabetic-wound therapy

    For qualifying diabetic wounds, coverage is continued only when all of the following ongoing requirements are met:

    Continuation therapy

    • The wound is evaluated at least every 30 days during administration of HBOT.Evaluation at least every 30 days
    • Measurable signs of healing are demonstrated within each 30-day treatment period.Measurable healing within each 30-day period

      Continued HBOT is not covered if measurable signs of healing have not been demonstrated within any 30-day period of treatment.

    Topical oxygen therapy, including topical oxygen delivery systems, topical hyperbaric oxygen chambers, and any related professional services, is excluded. Topical application of oxygen does not meet the policy definition of hyperbaric oxygen therapy.

    HBOT is not covered for uses that lack a recommendation from the Hyperbaric Oxygen Therapy Committee of the Undersea and Hyperbaric Medical Society (UHMS). Examples include treatment of decubitus ulcers, Lyme disease, migraine of any etiology, complex regional pain syndrome, fibromyalgia, cerebral palsy, autistic disorder, and chronic fatigue syndrome.

    Mild hyperbaric oxygen therapy delivered at pressures lower than 1.5 ATA is not covered because clinical evidence of effectiveness has not been established.

    HBOT is not covered for prevention of mandibular osteoradionecrosis, including treatment provided before or after dental extraction.

    HBOT is not covered to prevent complications of, or improve survival of, intraoral implants in an irradiated field.

    Coverage is subject to the member's Evidence of Coverage and other applicable benefit-plan provisions. A benefit plan may contain specific exclusions or limitations even when medical-necessity criteria are satisfied. If the policy conflicts with the member's benefit plan, the benefit-plan provisions govern, subject to applicable mandates.

    Topical hyperbaric oxygen chambers (A4575) and topical oxygen delivery systems (E0446) are denied as not reasonable and necessary. Professional services related to topical oxygen therapy are also excluded.

    Procedure Codes and Billing Rules

    Informational HBOT Procedure CodesCPT | HCPCS
    99183Physician or other qualified health care professional attendance and supervision of hyperbaric oxygen therapy, per session.
    G0277Hyperbaric oxygen under pressure, full body chamber, per 30-minute interval.
    Topical Oxygen Codes — Not Reasonable and NecessaryHCPCSNot Covered
    A4575Topical hyperbaric oxygen chambers.
    E0446Topical oxygen delivery systems.
    G0277 Additional-Unit Threshold
    CodeG0277
    Additional-unit thresholdAt least 16 minutes of the next 30-minute interval
    Billing ruleLess than 16 minutes should not be billed
    G0277 Billing Units
    16–45 minutes1 unit
    46–75 minutes2 units
    76–105 minutes3 units

    Authorization and Documentation Requirements

    Prior Authorization

    Emergency and Post-Stabilization Authorization

    Prior authorization is required for non-emergent hyperbaric oxygen therapy. Emergency medical-condition treatment does not require prior authorization, including emergent therapy that may involve several treatments during the first 24 hours. Post-stabilization hyperbaric oxygen therapy requires prior authorization after the member’s condition has stabilized, even when the services are related to the emergency condition.

    • Apply the emergency exception only to services treating an emergency medical condition.
    • Obtain prior authorization for post-stabilization hyperbaric oxygen therapy and all non-emergent therapy.
    Documentation Required

    Adult MassHealth and Community Care Review

    For MassHealth and Community Care members age 18 and older, Fallon Health uses the InterQual® medical-necessity criteria in effect on the date of service.

    Hyperbaric Oxygen Therapy Overview

    Hyperbaric oxygen therapy (HBOT) delivers physician-prescribed medical-grade oxygen in a hard-sided chamber while the patient breathes oxygen under increased pressure. Conventional treatment is generally provided at chamber pressures of at least 2.0 ATA for approximately 90–120 minutes per treatment, with the course and supervision determined by the treating physician. The policy distinguishes chamber-based HBOT from topical oxygen therapy and mild HBOT, which are not covered under the specified exclusions.

    Terms and Chamber Types

    Monoplace Chamber
    Chamber typeMonoplace chamber
    ConstructionHard-sided hyperbaric chamber
    CapacityAccommodates one person
    Multiplace Chamber
    Chamber typeMultiplace chamber
    ConstructionHard-sided hyperbaric chamber
    CapacityDesigned to accommodate two or more people
    Policy Summary
    PayerFallon Community Health Plan Inc
    PolicyHyperbaric Oxygen Therapy Clinical Coverage Criteria
    Policy CodePolicy N/A
    Change TypeAnnual review — no material clinical or coverage changes
    Effective DateSeptember 1, 2026
    Last ReviewAug 18, 2026
    Next Review DateN/A
    Key ActionObtain prior authorization for non-emergent hyperbaric oxygen therapy and for post-stabilization treatment after an emergency.
    SourceLink
    On This Page
    Covered Services and ExclusionsProcedure Codes and Billing RulesAuthorization and Documentation RequirementsHyperbaric Oxygen Therapy OverviewTerms and Chamber Types
    106–135 minutes4 units
    Diabetic Wound Severity
    Required severityWagner grade III or higher
    Diabetes requirementType I or type II diabetes
    Wound locationLower-extremity wound due to diabetes
    Failure of Standard Wound Therapy
    Standard therapy outcomeNo measurable signs of healing
    Minimum durationAt least 30 consecutive days
    Treatment roleHBOT is covered as adjunctive therapy and must be used in addition to standard wound care
    Mild Hyperbaric Oxygen Pressure
    DefinitionExposure at pressures lower than 1.5 ATA
    Evidence statusMild hyperbaric oxygen therapy is unproven and has no clinical evidence of effectiveness
    Coverage statusMild hyperbaric oxygen therapy at pressures lower than 1.5 ATA is not covered
  1. Refer to InterQual® CP: Procedures, Hyperbaric Oxygen Therapy.
  2. Fallon Health makes the applicable InterQual criteria available through its public transparency tool.
  3. Documentation Required

    Pediatric Case-by-Case Review

    Hyperbaric oxygen therapy for MassHealth ACO and Community Care members younger than 18 is reviewed individually on a case-by-case basis.

    • Submit clinical documentation supporting the requested treatment and medical necessity for individual review.
    Billing Rule

    Medicare Coverage Variation

    For Medicare members, Medicare coverage criteria govern coverage of hyperbaric oxygen therapy. Fallon Health’s criteria do not apply when Medicare criteria are fully established.

    • Follow applicable Medicare statutes and regulations, national coverage determinations, and local coverage determinations.
    • Medicare NCD Hyperbaric Oxygen Therapy (20.29) applies; topical oxygen limitations may also appear in LCD L33797.
    Note

    MassHealth Coverage Criteria

    For MassHealth members, Fallon Health generally follows MassHealth medical-necessity guidelines. Because MassHealth has no guideline for hyperbaric oxygen therapy, Fallon Health’s Hyperbaric Oxygen Therapy Clinical Coverage Criteria apply, consistent with the applicable definition of medical necessity.

    • Use Fallon Health clinical criteria when MassHealth has no applicable medical-necessity guideline.
    • For NaviCare members, follow applicable Medicare criteria first; when those criteria do not establish coverage or are not met, follow applicable MassHealth guidelines and then Fallon criteria when appropriate.

    Unsupported block type: prior_auth

    Documentation Required

    Prescription, Oversight, and Facility Requirements

    Hyperbaric oxygen is a physician-prescribed and physician-supervised procedure. It must be delivered in a properly accredited hospital or facility using a hard-sided chamber that meets applicable ASME-PVHO-1 and NFPA 99 standards.

    • Use physician-prescribed medical-grade oxygen at a chamber pressure of at least 2.0 ATA.
    • Provide treatment in a hospital or facility properly accredited by the Undersea and Hyperbaric Medical Society (UHMS).
    Documentation Required

    Diabetic Wound Qualification

    For diabetic wounds of the lower extremities, document all qualifying elements before requesting coverage.

    • The member has type I or type II diabetes and the lower-extremity wound is due to diabetes.
    • The wound is Wagner grade III or higher.
    • The wound has failed an adequate course of standard wound therapy.
    Documentation Required

    Standard Wound Care

    HBOT for diabetic wounds is adjunctive therapy and must be provided with standard wound care after failure of an adequate course of that care.

    • Assess vascular status and correct vascular problems in the affected limb when possible.
    • Optimize nutritional status and glucose control.
    • Debride devitalized tissue by any appropriate means.
    • Maintain a clean, moist granulation-tissue bed with appropriate moist dressings.
    • Provide appropriate offloading and necessary treatment for any infection.
    Denial Risk

    30-Day Wound Reassessment

    Before initiating or continuing diabetic-wound HBOT, document the wound’s response to standard wound therapy and perform ongoing reassessment.

    • Coverage requires no measurable signs of healing for at least 30 consecutive days of standard wound therapy.
    • Evaluate the wound at least every 30 days during HBOT.
    • Continued HBOT is not covered unless measurable healing is demonstrated within each 30-day treatment period.

    Unsupported block type: denial_risk

    Denial Risk

    Topical Oxygen Therapy

    Topical oxygen therapy is not considered covered hyperbaric oxygen therapy under the applicable criteria. Related professional services are also subject to noncoverage limitations.

    • Topical hyperbaric oxygen chambers (A4575) are denied as not reasonable and necessary.
    • Topical oxygen delivery systems (E0446) are denied as not reasonable and necessary.
    • Any professional services related to topical oxygen therapy are excluded from coverage.
    Denial Risk

    No UHMS-Supported Indication

    HBOT is excluded when the use lacks a recommendation from the UHMS Hyperbaric Oxygen Therapy Committee.

    • Examples include decubitus ulcers, Lyme disease, migraine of any etiology, complex regional pain syndrome, fibromyalgia, cerebral palsy, autistic disorder, and chronic fatigue syndrome.
    • The exclusion also includes prevention of mandibular osteoradionecrosis before or after dental extraction and prevention of intraoral implant failure.
    Denial Risk

    Mild Hyperbaric Oxygen

    Mild hyperbaric oxygen therapy delivered at pressures below 1.5 ATA is not covered because clinical effectiveness has not been established.

    • Do not treat exposures below 1.5 ATA as covered HBOT under this policy.
    Denial Risk

    No Healing During Continuation

    Continued HBOT for a diabetic wound is not covered when measurable healing has not been demonstrated during a 30-day treatment period.

    • Document measurable healing within each 30-day period to support continuation.
    • Stop or reassess continued therapy when the required healing response is absent.
    Billing Rule

    Check Benefit-Specific Exclusions

    Verify the member’s specific benefit plan before providing or billing HBOT. The member’s Evidence of Coverage and benefit-plan terms may impose exclusions or limitations regardless of medical necessity.

    • Consult the applicable Evidence of Coverage for product- or employer-group-specific exclusions and limitations.
    • If this policy conflicts with the member’s benefit plan, the benefit-plan provisions govern, subject to applicable state and federal mandates.
    Mild Hyperbaric Oxygen Therapy
    DefinitionHyperbaric oxygen exposure delivered at a pressure lower than 1.5 ATA
    Clinical statusConsidered unproven or investigational
    Coverage statusNot covered when delivered at pressures lower than 1.5 ATA
    ATA
    MeaningAtmospheres absolute
    PurposePressure measurement used to describe chamber pressure
    Typical hyperbaric pressureHyperbaric oxygen is delivered at a pressure of not less than 2.0 ATA