Loading...

    Explore
    • Policy Monitoring
    • Live Policy Feed
    • Billing Codes
    • Healthcare Providers
    • Health Insurance Payers
    • States
    • Service Lines
    • Taxonomy Codes
    Lookup tools
    • Billing Code Lookup
    • CPT Modifier Lookup
    • Provider Taxonomy Code Lookup
    • Healthcare Provider & Facility Lookup
    • Health Insurance Payer Lookup
    • Payer Contact Directory

    Policy & Benchmark Tools

    • Prior Authorization Lookup
    • Coverage Criteria Lookup
    • Timely Filing Lookup
    • Billing Code Reimbursement Rates
    • Payer Comparison Dashboard
    • Facility Comparison Dashboard
    • All tools

    Company

    • About OpenPayer
    • Data Sources
    • Request a Policy / Feedback
    • Trek Health
    OpenPayerby Trek Health
    LinkedInYouTube

    © 2026 Trek Health. All rights reserved.

    OpenPayer is built and maintained by Trek Health.

    v1.0.32
    OpenPayerPolicy UpdatesOrthopedics/MusculoskeletalCentene Osteogenic Stimulation Coverage Update | O…
    Ask Trek AI about this page
    ModifiedCentenePolicy CP MP.194

    Osteogenic Stimulation

    Customize your policy alerts

    Sign up for Centene Policy CP MP.194 alerts

    Get alerted when Policy CP MP.194 changes without checking for updates manually.

    Monitor payer policy activity

    Receive email alerts as soon as relevant payer policies are published or updated.

    Medical necessity criteria for invasive and noninvasive electrical and ultrasonic osteogenic stimulators to enhance bone healing, for providers and payers affiliated with Centene Corporation.

    Policy Summary
    PayerCentene
    PolicyOsteogenic Stimulation
    Policy CodePolicy CP MP.194
    Change TypeCoding addition (HCPCS E0760) and wording/format clarifications
    Effective Date
    Next Review Date
    Key ActionObtain prior authorization per Centene policy for osteogenic stimulation devices referenced by the policy's CPT/HCPCS codes.
    SourceLink
    POLICY UPDATE CHANGES

    Added HCPCS code E0760 for low intensity ultrasound osteogenesis stimulator.

    Updated Criteria I.A.3. and II.A.3. to state 'appropriate fracture care and immobilization' and changed language from 'radiographs' to 'imaging' in multiple criteria.

    Reformatted criteria and changed previous criteria structure (e.g., III.A.6.a.-b. to new III.B.1.-2.) with no impact on criteria.

    OpenPayer is powered by Trek Health's payer performance platform. Trek continuously ingests, validates, and normalizes Transparency in Coverage data alongside payer policies and other commercial payer data to create a structured payer intelligence foundation. OpenPayer uses this foundation to deliver personalized search results, dynamically generated policy pages, and tailored policy monitoring based on each user's payers, specialties, billing codes, and areas of interest. The same intelligence powers broader payer performance workflows, including reimbursement benchmarking, contract evaluation, payer negotiations, and financial decision-making.

    3device categories covered
    >=90dmin time since fracture/surgery
    >=2min imaging sets required
    85-100%LIPUS reported healing
    listedpeer-reviewed refs

    Medical Necessity Criteria

    Noninvasive electrical stimulation

    Covered — ANY of the following apply

    Nonunion due to congenital pseudoarthrosis
    Failed fusion of a joint (other than spine) with at least six months elapsed since last surgery
    As an adjunct to spinal fusion for patients at high risk of pseudoarthrosis due to previously failed fusion or for multilevel spinal fusion (three or more vertebrae)
    Risk factors for delayed or nonunion (e.g., alcoholism, chemotherapy, diabetes, obesity, osteoporosis, renal disease, tobacco or steroid use)

    Invasive electrical stimulation

    Covered — ANY of the following apply

    Failed spinal fusion where a minimum of nine months has elapsed since the last surgery
    Adjunct to spinal fusion for patients at high risk of pseudoarthrosis
    Following multilevel spinal fusion (three or more vertebrae) or where there is prior failed fusion at same site
    Risk factors for delayed or nonunion (e.g., alcoholism, chemotherapy, diabetes, obesity, osteoporosis, renal disease, tobacco or steroid use)

    Referenced Codes and Coding Rules

    Referenced CPT CodesCPT
    20974
    20975Electrical stimulation to aid bone healing; invasive (operative).
    20979Low intensity ultrasound stimulation to aid bone healing_noninvasive (nonoperative
    Referenced HCPCS CodesHCPCS
    A4559Coupling or gel.
    E0747Osteogenesis stimulator; electrical, noninvasive; other than spinal applications.
    E0748Osteogenesis stimulator; electrical, noninvasive, spinal applications.
    E0749Osteogenesis stimulator; electrical_surgically implanted.
    E0760Osteogenesis stimulator; low intensity_ultrasound_noninvasive
    Imaging confirmation interval — minimum two sets separated by ≥90 days
    RequirementSerial imaging must include a minimum of two sets of images, each with multiple views, separated by at least 90 days.
    PurposeTo document that fracture healing has ceased for three or more months prior to initiating osteogenic stimulation.
    Applies toUsed as part of nonunion criteria for both noninvasive and invasive electrical stimulators and for LIPUS nonunion indications.
    Imaging contentEach set must include multiple views of the fracture site.
    Elapsed time for nonunion — at least 90 days since fracture or surgical treatment
    Elapsed time threshold

    Prior Authorization, Documentation, and Billing Guidance

    Prior Authorization

    Prior authorization required for referenced CPT/HCPCS codes

    Prior authorization is required for osteogenic stimulation services and devices referenced by the policy CPT and HCPCS codes; providers must obtain any required authorization before billing.

    • Codes referenced in the policy include CPT: 20974, 20975, 20979 and HCPCS: A4559, E0747, E0748, E0749, E0760.
    • Inclusion of codes in the policy does not guarantee coverage; obtain prior authorization per Health Plan rules.
    Prior Authorization

    Health Plan may require adherence to this clinical policy

    The Health Plan may require adherence to this clinical policy when making coverage decisions; providers should verify applicable prior authorization and coverage rules with the member's Health Plan prior to requesting or delivering services.

    • Coverage decisions and administration of benefits are subject to Health Plan-level administrative policies and procedures.
    • Providers should confirm plan-specific prior authorization requirements and state/federal requirements.

    Clinical Background and Evidence Summary

    Fracture healing is a complex biological process and while most fractures heal with standard treatment, approximately 5–10% may have delayed healing or nonunion. Standard management includes stabilization (internal or external fixation, casting) and, when indicated, bone grafting; osteogenic stimulators (electrical or low-intensity pulsed ultrasound) are considered adjunctive therapies to promote bone formation in selected cases where healing is delayed, ceased, or when patients have risk factors for impaired healing.

    Device and Term Definitions

    Noninvasive electrical osteogenic stimulators (PEMF, CC, CEMF) — definitions
    PEMF (Pulsed Electromagnetic Field)Noninvasive system delivering electromagnetic fields via externally placed treatment coils to stimulate bone healing.
    Capacitive coupling (CC)Noninvasive delivery of electrical current to the fracture site using externally applied electrodes or coils.
    Combined electromagnetic field (CEMF / CMFT)Noninvasive technology combining magnetic field modalities delivered externally to the fracture site to promote osteogenesis.
    Invasive vs noninvasive distinctionInvasive (implantable) stimulators deliver direct current via implanted electrodes; noninvasive systems use external coils or electrodes.
    Low-intensity pulsed ultrasound devices (LIPUS) — application details
    Daily application time

    Policy Updates

    2024-07-24annual_review

    Annual review completed; wording clarified in multiple criteria (e.g., changed 'radiographs' to 'imaging' and updated 'appropriate fracture care and immobilization'); background and references reviewed — no change to clinical intent.

    2024-06-25formatting_update

    Annual review reformatted criteria (reorganized criteria numbering and sections) with no impact on clinical criteria; references reviewed and updated.

    2021-09-21coding_update
    Policy Summary
    PayerCentene
    PolicyOsteogenic Stimulation
    Policy CodePolicy CP MP.194
    Change TypeCoding addition (HCPCS E0760) and wording/format clarifications
    Effective Date
    Next Review Date
    Key ActionObtain prior authorization per Centene policy for osteogenic stimulation devices referenced by the policy's CPT/HCPCS codes.
    SourceLink
    On This Page
    Medical Necessity CriteriaReferenced Codes and Coding RulesPrior Authorization, Documentation, and Billing GuidanceClinical Background and Evidence SummaryDevice and Term DefinitionsPolicy Updates
    At least 90 days have passed since the date of fracture or the date of surgical treatment of the fracture.
    ContextRequired for classification of long bone nonunion when considering noninvasive electrical stimulation.
    Also referenced forDocumentation of nonunion before initiating invasive electrical stimulators (with same imaging/stability requirements).
    Step Therapy

    Demonstrate failed healing or risk factors and proper stabilization before device use

    Before initiating an osteogenic stimulator, documentation must demonstrate failed healing or presence of risk factors and that the fracture site is appropriately stabilized (e.g., appropriate fracture care and immobilization); the policy requires these prerequisites prior to device use.

    • Policy requires that the bone be stable at both ends by means of appropriate fracture care and immobilization.
    • Policy allows use when risk factors for delayed or nonunion are present (examples listed include alcoholism, chemotherapy, diabetes, obesity, osteoporosis, renal disease, tobacco or steroid use).
    Documentation Required

    Imaging documentation required for nonunion: ≥2 image sets separated by ≥90 days

    For nonunion cases, documentation must include serial imaging showing healing has ceased for three or more months, with a minimum of two sets of images (each including multiple views) obtained and separated by at least 90 days prior to starting treatment.

    • Each imaging set must include multiple views of the fracture site.
    • The two sets must be separated by a minimum of 90 days to confirm cessation of healing.
    Documentation Required

    Provider responsibilities: follow policy criteria and submit required documentation

    Providers must follow the policy's clinical criteria and supply required documentation when requesting authorization or submitting claims; adherence to these provider obligations is expected when delivering services to Health Plan members.

    • Submit clinical documentation that aligns with the policy criteria (e.g., imaging, timing since fracture/surgery, stabilization details).
    • Ensure device use meets the specific indications and thresholds defined in the policy.
    Note

    Submitting claims binds providers to policy terms and conditions

    By submitting claims for payment, providers and their representatives agree to be bound by the terms and conditions expressed in this clinical policy and related contractual agreements.

    • Providers are independent contractors and are bound to the policy terms through contract or by submitting services/claims.
    • Unauthorized use or distribution of the policy is prohibited.
    Note

    Coverage decisions subject to member contract terms and plan administration

    Coverage decisions and administration of benefits are subject to the member's coverage documents (e.g., evidence of coverage, certificate of coverage), applicable state and federal requirements, and Health Plan-level administrative policies and procedures; conflicts with state Medicaid provisions defer to the state Medicaid manual.

    • This clinical policy is a guide to medical necessity and does not constitute a contract or guarantee of payment.
    • State Medicaid coverage provisions take precedence over this clinical policy when they conflict.
    Approximately 20 minutes once daily at home until healing is achieved.
    Method of useDevice is applied externally to the skin over the fracture site using conductive coupling (gel) for ultrasound transmission.
    Indications notedUsed as adjunct to stabilization for fresh fractures at high risk for delayed healing and as secondary therapy for nonunions.
    Prescribed useLIPUS devices are prescribed by a physician for home use by the patient.
    Definition of multilevel spinal fusion — involving three or more vertebrae
    DefinitionA multilevel spinal fusion involves fusion across three or more vertebrae.
    Context of useReferenced as a qualifying condition for adjunctive use of osteogenic stimulators in high-risk spinal fusion patients.
    Policy update noteDefinition was added/clarified in the policy revisions and applies to criteria for invasive and noninvasive adjunctive use.
    Latest

    Added HCPCS code E0760 for low intensity ultrasound osteogenesis stimulator (coding implication update).