Loading...

    Explore
    • Policy Monitoring
    • Live Policy Feed
    • Billing Codes
    • Healthcare Providers
    • Health Insurance Payers
    • States
    • Service Lines
    • Taxonomy Codes
    Lookup tools
    • Billing Code Lookup
    • CPT Modifier Lookup
    • Provider Taxonomy Code Lookup
    • Healthcare Provider & Facility Lookup
    • Health Insurance Payer Lookup
    • Payer Contact Directory

    Policy & Benchmark Tools

    • Prior Authorization Lookup
    • Coverage Criteria Lookup
    • Timely Filing Lookup
    • Billing Code Reimbursement Rates
    • Payer Comparison Dashboard
    • Facility Comparison Dashboard
    • All tools

    Company

    • About OpenPayer
    • Data Sources
    • Request a Policy / Feedback
    • Trek Health
    OpenPayerby Trek Health
    LinkedInYouTube

    © 2026 Trek Health. All rights reserved.

    OpenPayer is built and maintained by Trek Health.

    v1.0.31
    OpenPayerPolicy UpdatesClinical/Medical PolicyBlue Shield California Actigraphy Coverage | OpenP…
    Ask Trek AI about this page
    CurrentBlue Shield of CaliforniaPolicy 2.01.73

    Actigraphy

    Customize your policy alerts

    Sign up for blue_shield_of_california Policy 2.01.73 alerts

    Get alerted when Policy 2.01.73 changes without checking for updates manually.

    Monitor payer policy activity

    Receive email alerts as soon as relevant payer policies are published or updated.

    This policy governs coverage of actigraphy used to assess sleep-wake patterns and body movement, including its use in evaluating sleep disorders. Sole-technique actigraphy is investigational; actigraphy incorporated into portable sleep monitoring is addressed separately and must not be reported separately.

    Policy Summary
    PayerBlue Shield of California
    PolicyActigraphy
    Policy CodePolicy 2.01.73
    Change TypeNo material change
    Effective DateSep 1, 2026
    Next Review DateN/A
    Key ActionDo not separately report actigraphy when it is used as a component of portable sleep monitoring under CPT codes 95800 or 95806.
    SourceLink
    POLICY UPDATE CHANGES

    No material clinical or coverage changes in this revision.

    InvestigationalSole-technique actigraphy
    None requiredClinical review documentation
    72 hours–14 daysActigraphy recording duration
    26.1%Sensitivity in central hypersomnolence

    Coverage Criteria

    OpenPayer is powered by Trek Health's payer performance platform. Trek continuously ingests, validates, and normalizes Transparency in Coverage data alongside payer policies and other commercial payer data to create a structured payer intelligence foundation. OpenPayer uses this foundation to deliver personalized search results, dynamically generated policy pages, and tailored policy monitoring based on each user's payers, specialties, billing codes, and areas of interest. The same intelligence powers broader payer performance workflows, including reimbursement benchmarking, contract evaluation, payer negotiations, and financial decision-making.

    Sole-Technique Actigraphy

    Actigraphy is considered investigational when all of the following apply.

    Actigraphy used as sole technique: Actigraphy is used as the sole technique to record and analyze body movement, including but not limited to its use to evaluate sleep disorders.

    This use is considered investigational.

    Portable Sleep Monitoring Component

    Portable sleep monitoring is addressed separately.

    Actigraphy incorporated into portable sleep monitoring: Actigraphy is used as a component of portable sleep monitoring under CPT code 95800 or 95806.

    This policy does not address this use; actigraphy should not be separately reported.

    Investigational Use—Actigraphy as the Sole Technique

    Actigraphy is considered investigational when used as the sole technique.

    Sole-technique use: Actigraphy is used as the sole technique to record and analyze body movement, including but not limited to its use to evaluate sleep disorders.

    This does not include use of actigraphy as a component of portable sleep monitoring.

    Actigraphy used as a component of portable sleep monitoring under CPT codes 95800 or 95806 is addressed separately under the related obstructive sleep apnea policy and should not be reported separately.

    The investigational designation applies when actigraphy is used as the sole technique to record and analyze body movement, including for evaluation of sleep disorders. This designation does not include actigraphy used as a component of portable sleep monitoring.

    Coding and Reporting

    Portable sleep monitoring codes referencedCPT
    95800CPT code referenced for portable sleep monitoring; the document does not provide a code description.
    95806CPT code referenced for portable sleep monitoring; the document does not provide a code description.
    CPTCPT
    95803Actigraphy testing, recording, analysis, interpretation, and report (minimum of 72 hours to 14 consecutive days of recording).
    Wake Bouts Threshold
    Cutoff95 wake bouts per night
    Condition evaluatedRapid eye movement sleep behavior disorder
    Actigraphy performance at cutoffSensitivity 26.1%; specificity 95.5%; positive predictive value 85.7%
    Actigraphy Recording Duration
    CPT code95803
    Minimum recording duration72 hours
    Maximum recording duration14 consecutive days

    Provider and Billing Actions

    Documentation Required

    Clinical review documentation

    No records are required for clinical review.

    Denial Risk

    Sole-technique actigraphy is investigational

    Actigraphy is considered investigational when used as the sole technique to record and analyze body movement, including but not limited to its use to evaluate sleep disorders. Coverage may be denied when actigraphy is used in this manner.

    Billing Rule

    Do not separately report component actigraphy

    When actigraphy is used as a component of portable sleep monitoring under CPT codes 95800 or 95806, do not report the actigraphy separately.

    • CPT 95800
    • CPT 95806
    Denial Risk

    Sole-technique actigraphy is investigational

    Do not use actigraphy as the sole technique to record and analyze body movement, including for evaluation of sleep disorders, because this use is considered investigational. This designation does not include actigraphy used as a component of portable sleep monitoring.

    Background

    Actigraphy uses a device, typically worn on the wrist or ankle, to record body movement during sleep. Computer algorithms interpret the recorded activity to estimate periods of sleep and wake, including measures such as sleep onset, sleep offset, sleep latency, total sleep duration, and wake after sleep onset.

    Definitions

    Definition
    TermActigraphy
    DefinitionAssessment of body movement activity patterns using devices, typically placed on the wrist or ankle, during sleep.
    InterpretationComputer algorithms interpret the recorded activity as periods of sleep and wake.
    Definition
    TermCircadian sleep-wake rhythm disorders
    DefinitionDisorders involving the body's 24-hour internal physiologic systems, such as sleep, wakefulness, core temperature, and appetite.
    CausesThey may arise from intrinsic dysfunction or external factors such as shift work.
    Definition
    TermActigraphy
    DefinitionAssessment of body movement activity patterns during sleep using a device, typically placed on the wrist or ankle.
    Recording periodData are generally recorded for periods between 3 days and 2 weeks, although they can be collected continuously with regular downloading to a computer.
    Definition
    TermClinically valid
    DefinitionA test that detects the presence or absence of a condition, the future risk of developing a condition, or treatment response.
    Treatment responseTreatment response may be beneficial or adverse.
    Definition
    TermClinically useful
    DefinitionA test is clinically useful when its results inform management decisions that improve the net health outcome.
    Potential benefitThe net health outcome may improve through correct or more effective therapy or by avoiding unnecessary testing or therapy.
    Comparator Tests
    PolysomnographyThe criterion standard for evaluating sleep-wake cycles.
    Sleep diaries or logsRecord the individual's symptoms and are a key component of sleep-disorder evaluation.
    RolePolysomnography and sleep diaries or logs are comparator tests and tools used to make decisions about sleep-wake disorders.
    Definition
    TermZero-crossing mode
    MeasurementCounts the number of times the waveform crosses zero during each time period.
    UseA movement-measurement method used in actigraph assessment.
    Definition
    TermProportional-integral mode
    MeasurementMeasures the area under the curve and adds that size for each time period.
    UseA movement-measurement method used in actigraph assessment.
    Definition
    TermTime-above-threshold mode
    MeasurementUses a defined threshold and measures the length of time the waveform remains above that threshold.
    UseA movement-measurement method used in actigraph assessment.
    Definition
    TermClinically valid
    DefinitionA test is clinically valid when it detects the presence or absence of a condition, the future risk of developing a condition, or treatment response.
    Treatment responseTreatment response includes beneficial or adverse response.
    Definition
    TermClinically useful
    DefinitionA test is clinically useful when its results inform management decisions that improve the net health outcome of care.
    Potential benefitThe net health outcome may improve when patients receive correct or more effective therapy or avoid unnecessary therapy or testing.
    Definition
    TermDirect evidence
    DefinitionEvidence of clinical utility from studies comparing health outcomes for patients managed with and without the test.
    Preferred study designRandomized controlled trials are preferred because they are intervention studies.
    Definition
    TermChain of evidence
    DefinitionIndirect evidence of clinical utility rests on clinical validity.
    LimitationIf test performance is insufficiently demonstrated, clinical utility cannot be inferred.
    Definition
    TermActigraphy
    DefinitionAssessment of body-movement activity patterns using a device, typically placed on the wrist or ankle during sleep.
    InterpretationComputer algorithms interpret activity as periods of sleep and wake.
    Definition
    TermHypersomnolence
    DefinitionExcessive sleepiness when wakefulness would be expected.
    Associated disordersCentral disorders of hypersomnolence include narcolepsy, recurrent hypersomnia, and idiopathic hypersomnia.
    Definition
    TermClinically valid
    DefinitionA test is clinically valid when it detects the presence or absence of a condition, the future risk of developing a condition, or treatment response.
    Treatment responseTreatment response includes beneficial or adverse response.
    Definition
    TermClinically useful
    DefinitionA test is clinically useful when its results inform management decisions that improve the net health outcome of care.
    Potential benefitThe net health outcome may improve by enabling correct or more effective therapy or avoiding unnecessary therapy or testing.
    Definition
    TermDirect evidence
    DefinitionDirect clinical-utility evidence comes from studies comparing health outcomes in patients managed with and without the test.
    Preferred study designRandomized controlled trials are preferred because they are intervention studies.
    Definition
    TermChain of evidence
    DefinitionIndirect evidence of clinical utility rests on clinical validity.
    LimitationWhen test performance is insufficiently established, clinical utility cannot be inferred.
    Definition
    TermActigraphy
    DefinitionAssessment of body-movement activity patterns using a device, typically worn on the wrist or ankle during sleep.
    InterpretationComputer algorithms interpret the data as periods of sleep and wake.
    Definition
    TermClinically valid
    DefinitionA test is clinically valid when it detects the presence or absence of a condition, the future risk of developing a condition, or treatment response.
    Treatment responseTreatment response includes beneficial or adverse response.
    Definition
    TermClinically useful
    DefinitionA test is clinically useful when its results inform management decisions that improve the net health outcome of care.
    Potential benefitThe net health outcome may improve by enabling correct or more effective therapy or avoiding unnecessary therapy or testing.
    Definition
    TermDirect evidence
    DefinitionDirect evidence of clinical utility comes from studies comparing health outcomes in patients managed with and without the test.
    Preferred study designRandomized controlled trials are preferred.
    Definition
    TermChain of evidence
    DefinitionIndirect evidence of clinical utility rests on clinical validity.
    LimitationWhen test performance is insufficiently established, clinical utility cannot be inferred.
    Policy Summary
    PayerBlue Shield of California
    PolicyActigraphy
    Policy CodePolicy 2.01.73
    Change TypeNo material change
    Effective DateSep 1, 2026
    Next Review DateN/A
    Key ActionDo not separately report actigraphy when it is used as a component of portable sleep monitoring under CPT codes 95800 or 95806.
    SourceLink
    On This Page
    Coverage CriteriaCoding and ReportingProvider and Billing ActionsBackgroundDefinitions