Loading...

    Explore
    • Policy Monitoring
    • Live Policy Feed
    • Billing Codes
    • Healthcare Providers
    • Health Insurance Payers
    • States
    • Service Lines
    • Taxonomy Codes
    Lookup tools
    • Billing Code Lookup
    • CPT Modifier Lookup
    • Provider Taxonomy Code Lookup
    • Healthcare Provider & Facility Lookup
    • Health Insurance Payer Lookup
    • Payer Contact Directory

    Policy & Benchmark Tools

    • Prior Authorization Lookup
    • Coverage Criteria Lookup
    • Timely Filing Lookup
    • Billing Code Reimbursement Rates
    • Payer Comparison Dashboard
    • Facility Comparison Dashboard
    • All tools

    Company

    • About OpenPayer
    • Data Sources
    • Request a Policy / Feedback
    • Trek Health
    OpenPayerby Trek Health
    LinkedInYouTube

    © 2026 Trek Health. All rights reserved.

    OpenPayer is built and maintained by Trek Health.

    v1.0.32
    OpenPayerPolicy UpdatesSleep MedicineBCBS Rhode Island Phrenic Nerve Coverage | OpenPay…
    Ask Trek AI about this page
    CurrentBlue Cross Blue Shield - Rhode IslandPolicy N/A

    Phrenic Nerve Stimulation for Central Sleep Apnea

    Customize your policy alerts

    Sign up for all Blue Cross Blue Shield - Rhode Island policy alerts

    Know when Blue Cross Blue Shield - Rhode Island releases new policies or updates existing guidance.

    Monitor payer policy activity

    Receive email alerts as soon as relevant payer policies are published or updated.

    This policy governs coverage of phrenic nerve stimulation and associated neurostimulator procedures for central sleep apnea under Blue Cross Blue Shield of Rhode Island Medicare Advantage and commercial products. The technology is not covered for Medicare Advantage and is considered not medically necessary for commercial products because evidence is insufficient to determine effects on health outcomes.

    Policy Summary
    PayerBlue Cross Blue Shield - Rhode Island
    PolicyPhrenic Nerve Stimulation for Central Sleep Apnea
    Policy CodePolicy N/A
    Change TypeNo material change
    Effective DateJul 1, 2022
    Last ReviewJun 7, 2023
    Next Review DateN/A
    Key ActionDo not submit phrenic nerve stimulation for central sleep apnea as covered for Medicare Advantage or medically necessary for commercial products.
    SourceLink
    POLICY UPDATE CHANGES

    No material clinical or coverage changes in this revision.

    Not coveredMedicare Advantage coverage stance
    Not medically necessaryCommercial product coverage stance
    9Primary procedure codes
    4

    OpenPayer is powered by Trek Health's payer performance platform. Trek continuously ingests, validates, and normalizes Transparency in Coverage data alongside payer policies and other commercial payer data to create a structured payer intelligence foundation. OpenPayer uses this foundation to deliver personalized search results, dynamically generated policy pages, and tailored policy monitoring based on each user's payers, specialties, billing codes, and areas of interest. The same intelligence powers broader payer performance workflows, including reimbursement benchmarking, contract evaluation, payer negotiations, and financial decision-making.

    Removal-related codes
    1FDA-approved device
    Moderate to severe CSAFDA-approved indication

    Coverage Criteria

    For Medicare Advantage Plans, phrenic nerve stimulation for central sleep apnea is not covered because the evidence is insufficient to determine the technology’s effects on health outcomes.

    For Commercial Products, phrenic nerve stimulation for central sleep apnea is considered not medically necessary. The evidence is insufficient to determine the technology’s effects on health outcomes.

    Removal codes 0428T, 0429T, and 0430T should be reviewed under the related Removal of Implantable Devices policy. Code 0431T is not covered for Medicare Advantage and is not medically necessary for Commercial Products when billed for replacement; removal may be medically necessary when the criteria in the Removal of Implantable Devices policy are met.

    Coding and Procedure Codes

    Not covered for Medicare Advantage; not medically necessary for Commercial ProductsCPTNot Covered
    0424TInsertion or replacement of neurostimulator system for treatment of central sleep apnea; complete system (transvenous placement of right or left stimulation lead, sensing lead, implantable pulse generator)
    0425TInsertion or replacement of neurostimulator system for treatment of central sleep apnea; sensing lead only
    0426TInsertion or replacement of neurostimulator system for treatment of central sleep apnea; stimulation lead only
    0427TInsertion or replacement of neurostimulator system for treatment of central sleep apnea; pulse generator only
    0432TRepositioning of neurostimulator system for treatment of central sleep apnea; stimulation lead only
    0433TRepositioning of neurostimulator system for treatment of central sleep apnea; sensing lead only
    0434TInterrogation device evaluation implanted neurostimulator pulse generator system for central sleep apnea
    0435TProgramming device evaluation of implanted neurostimulator pulse generator system for central sleep apnea; single session
    0436TProgramming device evaluation of implanted neurostimulator pulse generator system for central sleep apnea; during sleep study
    Refer to Related Policy: Removal of Implantable DevicesCPT
    0428TRemoval of neurostimulator system for treatment of central sleep apnea; pulse generator only
    0429TRemoval of neurostimulator system for treatment of central sleep apnea; sensing lead only
    0430TRemoval of neurostimulator system for treatment of central sleep apnea; stimulation lead only
    Replacement not covered for Medicare Advantage and not medically necessary for Commercial Products; removal may be medically necessary under the Removal of Implantable Devices policyCPTNot Covered
    0431TRemoval and replacement of neurostimulator system for treatment of central sleep apnea, pulse generator only

    Provider and Billing Actions

    Denial Risk

    Phrenic Nerve Stimulation: Coverage Exclusion

    Phrenic nerve stimulation for central sleep apnea is not covered for Medicare Advantage Plans and is not medically necessary for Commercial Products because evidence is insufficient to determine its effects on health outcomes.

    • Medicare Advantage Plans: phrenic nerve stimulation is not covered.
    • Commercial Products: phrenic nerve stimulation is considered not medically necessary.
    Denial Risk

    Noncovered or Not Medically Necessary Procedure Codes

    The following temporary procedure codes are not covered for Medicare Advantage Plans and are not medically necessary for Commercial Products. Apply the product-specific coverage status when reviewing claims; removal-only services are governed separately by the Related Policy Removal of Implantable Devices policy, except as noted for code 0431T.

    • 0424T — Insertion or replacement of neurostimulator system for treatment of central sleep apnea; complete system (transvenous placement of right or left stimulation lead, sensing lead, implantable pulse generator).

    Clinical Background

    Central sleep apnea (CSA) is characterized by diminished or absent respiratory effort during sleep, with repetitive cessation or reduction of airflow and ventilatory effort. It may be idiopathic or secondary to conditions such as heart failure, stroke, medication use, or high-altitude breathing. Common management may include positive airway pressure, oxygen, bilevel therapy, adaptive servo-ventilation in selected patients, or respiratory stimulants. Phrenic nerve stimulation uses an implanted system to stimulate the diaphragm and is intended to normalize sleep-related breathing patterns.

    Key Definitions and Technology

    Central Sleep Apnea (CSA)
    ConditionSleep-disordered breathing caused by diminished or absent respiratory effort.
    Respiratory featuresRepetitive cessation or decrease in both airflow and ventilatory effort during sleep.
    ClassificationMay be idiopathic or secondary to a medical condition, drugs, or high-altitude breathing.
    Phrenic Nerve Stimulation
    SystemAn implanted, battery-powered device placed under the skin in the right or left pectoral region.
    ComponentsTwo leads: one stimulation lead directed to a phrenic nerve and one lead that senses breathing.
    Policy Summary
    PayerBlue Cross Blue Shield - Rhode Island
    PolicyPhrenic Nerve Stimulation for Central Sleep Apnea
    Policy CodePolicy N/A
    Change TypeNo material change
    Effective DateJul 1, 2022
    Last ReviewJun 7, 2023
    Next Review DateN/A
    Key ActionDo not submit phrenic nerve stimulation for central sleep apnea as covered for Medicare Advantage or medically necessary for commercial products.
    SourceLink
    On This Page
    Coverage CriteriaCoding and Procedure CodesProvider and Billing ActionsClinical BackgroundKey Definitions and Technology
  1. 0425T — Insertion or replacement of neurostimulator system for treatment of central sleep apnea; sensing lead only.
  2. 0426T — Insertion or replacement of neurostimulator system for treatment of central sleep apnea; stimulation lead only.
  3. 0427T — Insertion or replacement of neurostimulator system for treatment of central sleep apnea; pulse generator only.
  4. 0432T — Repositioning of neurostimulator system for treatment of central sleep apnea; stimulation lead only.
  5. 0433T — Repositioning of neurostimulator system for treatment of central sleep apnea; sensing lead only.
  6. 0434T — Interrogation device evaluation of implanted neurostimulator pulse generator system for central sleep apnea.
  7. 0435T — Programming device evaluation of implanted neurostimulator pulse generator system for central sleep apnea; single session.
  8. 0436T — Programming device evaluation of implanted neurostimulator pulse generator system for central sleep apnea; during sleep study.
  9. 0428T — Removal of neurostimulator system; pulse generator only. Refer to the Related Policy Removal of Implantable Devices policy.
  10. 0429T — Removal of neurostimulator system; sensing lead only. Refer to the Related Policy Removal of Implantable Devices policy.
  11. 0430T — Removal of neurostimulator system; stimulation lead only. Refer to the Related Policy Removal of Implantable Devices policy.
  12. 0431T — Removal and replacement of neurostimulator system; pulse generator only. Not covered for Medicare Advantage Plans and not medically necessary for Commercial Products for the replacement; removal may be medically necessary when criteria in the Related Policy Removal of Implantable Devices policy are met.
  13. Mechanism
    The system sends signals to the diaphragm to restore a normal breathing pattern; its algorithm activates automatically at night and suspends therapy when the individual sits up.
    remede System
    Deviceremede System (Respicardia, Inc.).
    Regulatory statusFDA-approved through the premarket approval application process in October 2017.
    Approved indicationTreatment of moderate to severe central sleep apnea in adults.