Loading...

    Explore
    • Policy Monitoring
    • Live Policy Feed
    • Billing Codes
    • Healthcare Providers
    • Health Insurance Payers
    • States
    • Service Lines
    • Taxonomy Codes
    Lookup tools
    • Billing Code Lookup
    • CPT Modifier Lookup
    • Provider Taxonomy Code Lookup
    • Healthcare Provider & Facility Lookup
    • Health Insurance Payer Lookup
    • Payer Contact Directory

    Policy & Benchmark Tools

    • Prior Authorization Lookup
    • Coverage Criteria Lookup
    • Timely Filing Lookup
    • Billing Code Reimbursement Rates
    • Payer Comparison Dashboard
    • Facility Comparison Dashboard
    • All tools

    Company

    • About OpenPayer
    • Data Sources
    • Request a Policy / Feedback
    • Trek Health
    OpenPayerby Trek Health
    LinkedInYouTube

    © 2026 Trek Health. All rights reserved.

    OpenPayer is built and maintained by Trek Health.

    v1.0.32
    OpenPayerPolicy UpdatesOtorhinolaryngology (ENT)BCBS Rhode Island Bone-Conduction Coverage | OpenP…
    Ask Trek AI about this page
    CurrentBlue Cross Blue Shield - Rhode IslandPolicy N/A

    Implantable Bone-Conduction and Bone-Anchored Hearing Aids

    Customize your policy alerts

    Sign up for all Blue Cross Blue Shield - Rhode Island policy alerts

    Know when Blue Cross Blue Shield - Rhode Island releases new policies or updates existing guidance.

    Monitor payer policy activity

    Receive email alerts as soon as relevant payer policies are published or updated.

    Coverage and medical necessity for fully or partially implantable bone-conduction and bone-anchored hearing aids, including implantation, replacement, removal, and device components, for Medicare Advantage and commercial products in Rhode Island.

    Policy Summary
    PayerBlue Cross Blue Shield - Rhode Island
    PolicyImplantable Bone-Conduction and Bone-Anchored Hearing Aids
    Policy CodePolicy N/A
    Change TypeNo material change
    Effective DateJan 1, 2023
    Last ReviewApr 16, 2025
    Next Review DateN/A
    Key ActionVerify the member's applicable benefit documents and eligibility before providing services.
    SourceLink

    OpenPayer is powered by Trek Health's payer performance platform. Trek continuously ingests, validates, and normalizes Transparency in Coverage data alongside payer policies and other commercial payer data to create a structured payer intelligence foundation. OpenPayer uses this foundation to deliver personalized search results, dynamically generated policy pages, and tailored policy monitoring based on each user's payers, specialties, billing codes, and areas of interest. The same intelligence powers broader payer performance workflows, including reimbursement benchmarking, contract evaluation, payer negotiations, and financial decision-making.

    POLICY UPDATE CHANGES

    No material clinical or coverage changes in this revision.

    5 yearsMinimum age for covered commercial indications
    2Primary commercial coverage pathways
    6Commercial ICD-10 diagnosis code ranges
    14CPT/HCPCS codes listed
    Bilateral sensorineural hearing lossNot medically necessary

    Medical Necessity and Coverage Criteria

    Medicare Advantage Plans

    For Medicare Advantage Plans:

    Implantable bone-conduction and bone-anchored hearing aids are covered.

    Commercial Conductive or Mixed Hearing Loss

    For Commercial Products, unilateral or bilateral fully or partially implantable bone-conduction (bone-anchored) hearing aids may be considered medically necessary as an alternative to an air-conduction hearing aid when ALL of the following are met:

    ALL of the following

    • The patient is 5 years of age or older.>= 5 years of age
    • The patient has a conductive or mixed hearing loss.
    • ONE of the following indications

      • Congenital or surgically induced malformations (e.g., atresia) of the external ear canal or middle ear.
      • Chronic external otitis or otitis media.
      • Tumors of the external canal and/or tympanic cavity.
      • Dermatitis of the external canal.

    Commercial Single-Sided Sensorineural Deafness

    For Commercial Products, an implantable bone-conduction (bone-anchored) hearing aid may be considered medically necessary as an alternative to an air-conduction contralateral routing of signal (CROS) hearing aid when ALL of the following are met:

    ALL of the following

    • The patient is 5 years of age or older.>= 5 years of age
    • The patient has single-sided sensorineural deafness.
    • The other ear has normal hearing.

    Other Uses and Bilateral Sensorineural Hearing Loss

    For Commercial Products:

    ALL of the following

    • The use is an other use of an implantable bone-conduction (bone-anchored) hearing aid outside the stated medically necessary indications.
    • The patient has bilateral sensorineural hearing loss.

    For Commercial Products, unilateral or bilateral fully or partially implantable bone-conduction (bone-anchored) hearing aids may be considered medically necessary as alternatives to air-conduction hearing aids only when the applicable coverage criteria are met.

    When the insertion of the device is not medically necessary, re-insertion of the device after removal is also considered not medically necessary.

    Other uses of implantable bone-conduction (bone-anchored) hearing aids, including use in patients with bilateral sensorineural hearing loss, are considered not medically necessary because the evidence is insufficient to determine the effects of the technology on health outcomes.

    The re-insertion exclusion applies when the device was removed and its original insertion was not medically necessary.

    Covered Services and Diagnosis Coding

    Medicare Advantage covered and Commercial medically necessary CPT/HCPCS codesmixedCovered
    69710Implantation or replacement of electromagnetic bone-conduction hearing device in temporal bone
    69711Removal or repair of electromagnetic bone conduction hearing device in temporal bone
    69714Implantation, osseointegrated implant, skull with percutaneous attachment to external speech processor
    69716Implantation, osseointegrated implant, skull; with magnetic transcutaneous attachment to external speech processor, within the mastoid and/or resulting in removal of less than 100 sq mm surface area of bone deep to the outer cranial cortex
    69717Replacement, including removal of existing device, osseointegrated implant, skull; with percutaneous attachment to external speech processor
    69719Replacement, including removal of existing device, osseointegrated implant, skull; with magnetic transcutaneous attachment to external speech processor, within the mastoid and/or involving a bony defect less than 100 sq mm surface area of bone deep to the outer cranial cortex
    69729Implantation, osseointegrated implant, skull; with attachment to external speech processor, outside of the mastoid
    69730Replacement, osseointegrated implant, skull; with attachment to external speech processor, outside the mastoid
    L8625External recharging system for battery for use with cochlear implant or auditory osseointegrated device, replacement only, each
    L8690Auditory osseointegrated device, includes all internal and external components
    1–10 of 13
    1/2
    ICD-10 diagnosis codes for Commercial Products onlyICD-10
    H60.60-H60.93ICD-10 diagnosis code range listed for Commercial Products
    H61.301-H61.399ICD-10 diagnosis code range listed for Commercial Products
    H65.20-H65.499ICD-10 diagnosis code range listed for Commercial Products
    H66.10-H66.3X9ICD-10 diagnosis code range listed for Commercial Products
    H90.0-H90.8ICD-10 diagnosis code range listed for Commercial Products
    Q16.0-Q16.9ICD-10 diagnosis code range listed for Commercial Products
    Medicare Advantage Plans and Commercial Products covered codesHCPCSCovered
    L8618Transmitter cable for use with cochlear implant device or auditory osseointegrated device, replacement
    L8624Lithium ion battery for use with cochlear implant or auditory osseointegrated device speech processor, ear level, replacement, each
    Commercial implantable bone-conduction indications
    Minimum age5 years and older
    Applicable hearing lossConductive or mixed hearing loss, or single-sided sensorineural deafness with normal hearing in the other ear
    Covered useAs an alternative to an air-conduction hearing aid or, for single-sided sensorineural deafness, an air-conduction CROS hearing aid
    Osia 2 system age indication
    Eligible populationAdults and children
    Minimum age12 years of age and older

    Provider and Member Responsibility

    Documentation Required

    Written Agreement Required for Member Self-Pay

    If services are determined to be not medically necessary, or are medically necessary but non-covered under the member’s benefits, obtain the member’s written agreement in advance before providing treatment at the member’s own expense. Follow applicable participation-agreement provisions.

    Denial Risk

    Use Only Covered Hearing-Loss Indications

    Use implantable bone-conduction (bone-anchored) hearing aids only for the covered commercial indications described in the policy. Other uses are considered not medically necessary.

    • Conductive or mixed hearing loss in patients age 5 or older with qualifying external-ear-canal or middle-ear malformations, chronic external otitis or otitis media, tumors of the external canal and/or tympanic cavity, or dermatitis of the external canal.
    • Single-sided sensorineural deafness with normal hearing in the other ear, as an alternative to an air-conduction CROS hearing aid.

    Clinical Background

    Hearing loss may be conductive, sensorineural, or mixed, and may affect one or both ears. Conductive loss results from dysfunction in sound transmission through the external or middle ear, whereas sensorineural loss involves the cochlea or neural auditory pathway. Mixed loss contains both conductive and sensorineural components.

    Bone-conduction systems transmit sound through the skull to the cochlea and may be useful when conventional air-conduction hearing aids cannot be used because of external-canal or middle-ear conditions. Implantable systems may use a percutaneous abutment that extends through the skin or transcutaneous magnetic coupling through the skin to implanted components. For selected unilateral sensorineural hearing loss, the system may be used with contralateral routing of signal, or CROS, in which a microphone on the affected side sends sound to an air-conduction hearing aid on the normal or less affected side.

    Hearing Loss and Device Definitions

    Conductive hearing loss
    DefinitionHearing loss caused by dysfunction in sound conduction through the external or middle ear.
    Affected structuresThe external ear canal or middle ear
    Hearing-loss classificationOne of the three hearing-loss types described in the policy; hearing loss may be unilateral or bilateral.
    Sensorineural hearing loss
    DefinitionHearing loss related to the cochlea or neural auditory pathway.
    Single-sided contextThe policy describes sensorineural deafness in one ear with normal hearing in the other ear as single-sided sensorineural deafness.
    Policy Summary
    PayerBlue Cross Blue Shield - Rhode Island
    PolicyImplantable Bone-Conduction and Bone-Anchored Hearing Aids
    Policy CodePolicy N/A
    Change TypeNo material change
    Effective DateJan 1, 2023
    Last ReviewApr 16, 2025
    Next Review DateN/A
    Key ActionVerify the member's applicable benefit documents and eligibility before providing services.
    SourceLink
    On This Page
    Medical Necessity and Coverage CriteriaCovered Services and Diagnosis CodingProvider and Member ResponsibilityClinical BackgroundHearing Loss and Device Definitions
    IndicationsConductive hearing loss, mixed hearing loss, and single-sided sensorineural deafness
    Denial Risk

    Bilateral Sensorineural Hearing Loss

    Implantable bone-conduction (bone-anchored) hearing aids for patients with bilateral sensorineural hearing loss are considered not medically necessary because evidence is insufficient to determine the technology’s effects on health outcomes.

    Denial Risk

    Re-insertion After Noncovered Insertion

    When the original device insertion was not medically necessary, re-insertion of the device after removal is also considered not medically necessary.

    Note

    Verify Benefit-Specific Limitations

    Benefits and coverage limitations may vary by group or contract. Review the applicable plan documents before providing services.

    • Benefit Booklet
    • Evidence of Coverage
    • Subscriber Agreement
    Documentation Required

    Verify Member Benefits and Eligibility

    Confirm member-specific eligibility and benefit status under the member’s subscriber agreement, member certificate, and/or employer agreement. These documents supersede the medical policy; contact the provider call center for information about member-specific benefits.

    Covered alternative
    For qualifying single-sided sensorineural deafness, an implantable bone-conduction or bone-anchored hearing aid may be an alternative to an air-conduction CROS hearing aid.
    Mixed hearing loss
    DefinitionA hearing loss containing both conductive and sensorineural components.
    Hearing-loss classificationMixed hearing loss is one of the hearing-loss types described in the policy and may be unilateral or bilateral.
    Covered alternativeFor patients age 5 years and older who meet a qualifying indication, an implantable bone-conduction or bone-anchored hearing aid may be used as an alternative to an air-conduction hearing aid.
    Contralateral routing of signal (CROS)
    DefinitionA system in which a microphone on the affected side transmits a signal to an air-conduction hearing aid on the normal or less affected side.
    Hearing-aid configurationThe receiving device is an air-conduction hearing aid on the normal or less affected side.
    Policy applicationAn implantable bone-conduction or bone-anchored hearing aid may be considered as an alternative to an air-conduction CROS hearing aid for qualifying single-sided sensorineural deafness.
    Percutaneous bone-anchored hearing system
    DefinitionA bone-conduction implant system that connects the sound processor to the skull through an abutment that permanently protrudes through the skin.
    Skull connectionA vibrational transducer is coupled directly to the skull through the percutaneous abutment.
    Implant structureThe abutment protrudes from a small titanium implant anchored in the temporal bone.
    Transcutaneous bone-anchored hearing system
    DefinitionA bone-conduction implant system in which the external sound processor couples magnetically through the skin to internally implanted components.
    Magnetic couplingMagnets in the external processor adhere to magnets implanted in shallow bone beds with the bone-conduction implant.
    Abutment requirementNo percutaneous abutment is needed to physically connect the external and internal components.