Loading...

    Explore
    • Policy Monitoring
    • Live Policy Feed
    • Billing Codes
    • Healthcare Providers
    • Health Insurance Payers
    • States
    • Service Lines
    • Taxonomy Codes
    Lookup tools
    • Billing Code Lookup
    • CPT Modifier Lookup
    • Provider Taxonomy Code Lookup
    • Healthcare Provider & Facility Lookup
    • Health Insurance Payer Lookup
    • Payer Contact Directory

    Policy & Benchmark Tools

    • Prior Authorization Lookup
    • Coverage Criteria Lookup
    • Timely Filing Lookup
    • Billing Code Reimbursement Rates
    • Payer Comparison Dashboard
    • Facility Comparison Dashboard
    • All tools

    Company

    • About OpenPayer
    • Data Sources
    • Request a Policy / Feedback
    • Trek Health
    OpenPayerby Trek Health
    LinkedInYouTube

    © 2026 Trek Health. All rights reserved.

    OpenPayer is built and maintained by Trek Health.

    v1.0.32
    OpenPayerPolicy UpdatesOtorhinolaryngology (ENT)BCBS Rhode Island Bone-Conduction Coverage | OpenP…
    Ask Trek AI about this page
    CurrentBlue Cross Blue Shield - Rhode IslandPolicy N/A

    Implantable Bone-Conduction and Bone-Anchored Hearing Aids

    Customize your policy alerts

    Sign up for all Blue Cross Blue Shield - Rhode Island policy alerts

    Know when Blue Cross Blue Shield - Rhode Island releases new policies or updates existing guidance.

    Monitor payer policy activity

    Receive email alerts as soon as relevant payer policies are published or updated.

    Coverage and medical necessity for implantable bone-conduction and bone-anchored hearing aids, related implantation, replacement, removal, repair, and device components for Medicare Advantage Plans and Commercial Products.

    Policy Summary
    PayerBlue Cross Blue Shield - Rhode Island
    PolicyImplantable Bone-Conduction and Bone-Anchored Hearing Aids
    Policy CodePolicy N/A
    Change TypeNo material change
    Effective DateJan 1, 2023
    Last ReviewApr 15, 2026
    Next Review DateN/A
    Key ActionVerify member-specific benefits and eligibility because the member agreement supersedes this policy.
    SourceLink
    POLICY UPDATE CHANGES

    No material clinical or coverage changes in this revision.

    5+Minimum age for covered Commercial indications
    4Qualifying indication categories
    8

    OpenPayer is powered by Trek Health's payer performance platform. Trek continuously ingests, validates, and normalizes Transparency in Coverage data alongside payer policies and other commercial payer data to create a structured payer intelligence foundation. OpenPayer uses this foundation to deliver personalized search results, dynamically generated policy pages, and tailored policy monitoring based on each user's payers, specialties, billing codes, and areas of interest. The same intelligence powers broader payer performance workflows, including reimbursement benchmarking, contract evaluation, payer negotiations, and financial decision-making.

    Commercial procedure codes
    7Diagnosis code ranges
    Not medically necessaryOther uses
    79References cited

    Medical Necessity and Coverage Criteria

    Medicare Advantage Plans

    Covered for Medicare Advantage Plans.

    Implantable bone-conduction and bone anchored hearing aids are covered.

    Commercial Products: Conductive or Mixed Hearing Loss

    For Commercial Products, unilateral or bilateral fully or partially implantable bone-conduction (bone-anchored) hearing aids may be considered medically necessary as an alternative to an air-conduction hearing aid when ALL of the following are met:

    ALL of the following

    • The patient is 5 years of age or older.>= 5 years of age
    • The patient has a conductive or mixed hearing loss.
    • The device is being used as an alternative to an air-conduction hearing aid.
    • ONE of the following indications

      • Congenital or surgically induced malformations (e.g., atresia) of the external ear canal or middle ear.
      • Chronic external otitis or otitis media.
      • Tumors of the external canal and/or tympanic cavity.
      • Dermatitis of the external canal.

    Commercial Products: Single-Sided Sensorineural Deafness

    For Commercial Products, an implantable bone-conduction (bone-anchored) hearing aid may be considered medically necessary as an alternative to an air-conduction contralateral routing of signal (CROS) hearing aid when ALL of the following are met:

    ALL of the following

    • The patient is 5 years of age or older.>= 5 years of age
    • The patient has single-sided sensorineural deafness.
    • The patient has normal hearing in the other ear.
    • The device is being used as an alternative to an air-conduction contralateral routing of signal (CROS) hearing aid.

    Other uses of implantable bone-conduction (bone-anchored) hearing aids, including use in patients with bilateral sensorineural hearing loss, are considered not medically necessary because the evidence is insufficient to determine the effects of the technology on health outcomes.

    In situations where the insertion of the device is not medically necessary, re-insertion of the device after removal is also considered not medically necessary.

    For Commercial Products, uses of implantable bone-conduction (bone-anchored) hearing aids outside the specified conductive, mixed, and single-sided sensorineural deafness indications are considered not medically necessary.

    For Commercial Products, re-insertion of the device after removal is considered not medically necessary when the initial insertion was not medically necessary.

    Covered Procedure, Diagnosis, and Device Codes

    Commercial Products: medically necessary CPT and HCPCS codes when filed with applicable ICD-10 diagnosis codesmixedCovered
    69710Implantation or replacement of electromagnetic bone-conduction hearing device in temporal bone
    69711Removal or repair of electromagnetic bone conduction hearing device in temporal bone
    69714Implantation, osseointegrated implant, skull with percutaneous attachment to external speech processor
    69716Implantation, osseointegrated implant, skull; with magnetic transcutaneous attachment to external speech processor, within the mastoid and/or resulting in removal of less than 100 sq mm surface area of bone deep to the outer cranial cortex
    69717Replacement (including removal of existing device), osseointegrated implant, skull; with percutaneous attachment to external speech processor
    69719Replacement (including removal of existing device), osseointegrated implant, skull; with magnetic transcutaneous attachment to external speech processor, within the mastoid and/or involving a bony defect less than 100 sq mm surface area of bone deep to the outer cranial cortex
    69729Implantation, osseointegrated implant, skull; with attachment to external speech processor, outside of the mastoid
    69730Replacement osseointegrated implant, skull; with attachment to external speech processor, outside the mastoid
    L8625External recharging system for battery for use with cochlear implant or auditory osseointegrated device, replacement only, each
    L8690Auditory osseointegrated device, includes all internal and external components
    1–10 of 13
    1/2
    Commercial Products: ICD-10 diagnosis codesICD-10Covered
    H60.60-H60.93ICD-10 diagnosis code range listed for Commercial Products
    H61.301-H61.399ICD-10 diagnosis code range listed for Commercial Products
    H65.20-H65.499ICD-10 diagnosis code range listed for Commercial Products
    H66.10-H66.3X9ICD-10 diagnosis code range listed for Commercial Products
    H90.0-H90.8ICD-10 diagnosis code range listed for Commercial Products
    Q16.0-Q16.9ICD-10 diagnosis code range listed for Commercial Products
    Medicare Advantage Plans and Commercial Products: covered device componentsHCPCSCovered
    L8618Transmitter cable for use with cochlear implant device or auditory osseointegrated device, replacement
    L8624Lithium ion battery for use with cochlear implant or auditory osseointegrated device speech processor, ear level, replacement, each

    Provider Responsibilities and Denial Risks

    Billing Rule

    Advance Written Agreement for Member-Paid Services

    Before providing services determined to be not medically necessary—or medically necessary services that are non-covered benefits—inform the member and obtain the member’s written agreement in advance to continue treatment at the member’s own expense. Do not charge the member without this advance written agreement; follow applicable participation-agreement provisions.

    • Applies when services are determined to be not medically necessary or are medically necessary but non-covered.
    • The member must be informed and agree in writing before treatment continues at the member’s expense.
    Denial Risk

    Non-Covered Clinical Use

    For Commercial Products, implantable bone-conduction (bone-anchored) hearing aids may be denied when used outside covered indications. Other uses are considered not medically necessary, including use in patients with bilateral sensorineural hearing loss, because evidence is insufficient to determine effects on health outcomes.

    Technology Background

    Implantable bone-conduction and bone-anchored hearing systems transmit sound through the skull to the cochlea. Systems may use a percutaneous abutment, which couples a vibrational transducer directly to the skull through an attachment that protrudes through the skin, or transcutaneous magnetic coupling, which transmits sound through the skin to internally implanted components. These systems may provide an alternative when conventional air-conduction hearing aids are unsuitable because of external-ear-canal or middle-ear conditions; selected patients with single-sided sensorineural deafness may also use them as an alternative to a contralateral routing of signal (CROS) hearing aid.

    Key Hearing-System Terms

    Contralateral Routing of Signal (CROS)
    SystemContralateral routing of signal (CROS)
    Microphone placementA microphone is placed on the affected side.
    Signal destinationThe microphone transmits the signal to an air-conduction hearing aid on the normal or less affected side.
    Percutaneous Bone-Anchored Implant
    Implant typeA bone-anchored implant system with a vibrational transducer coupled directly to the skull.
    ConnectionThe transducer is coupled through a percutaneous abutment that permanently protrudes through the skin.
    Implant material and location
    Policy Summary
    PayerBlue Cross Blue Shield - Rhode Island
    PolicyImplantable Bone-Conduction and Bone-Anchored Hearing Aids
    Policy CodePolicy N/A
    Change TypeNo material change
    Effective DateJan 1, 2023
    Last ReviewApr 15, 2026
    Next Review DateN/A
    Key ActionVerify member-specific benefits and eligibility because the member agreement supersedes this policy.
    SourceLink
    On This Page
    Medical Necessity and Coverage CriteriaCovered Procedure, Diagnosis, and Device CodesProvider Responsibilities and Denial RisksTechnology BackgroundKey Hearing-System Terms
    • Covered clinical indications include conductive or mixed hearing loss in patients age 5 and older with specified external- or middle-ear conditions, or single-sided sensorineural deafness with normal hearing in the other ear.
    • Uses outside these conductive, mixed, and single-sided sensorineural deafness indications may be denied.
    Denial Risk

    Re-insertion After Non-Medically Necessary Insertion

    When the initial insertion of an implantable bone-conduction hearing aid is not medically necessary, re-insertion after removal is also considered not medically necessary and may be denied.

    • The denial risk applies to re-insertion following removal when the original insertion was not medically necessary.
    • Replacement after such removal is likewise subject to this non-medically necessary determination.
    Note

    Verify Member-Specific Benefits

    Verify member-specific benefits and eligibility before treatment. Payment and coverage are determined by the member’s subscriber agreement or certificate and/or employer agreement, which supersede this policy when applicable.

    • Confirm coverage, payment responsibility, and eligibility with the provider call center.
    • Review applicable subscriber or employer agreement terms.
    The abutment extends from a small titanium implant anchored in the temporal bone.
    Transcutaneous Bone-Anchored System
    System typeA partially implantable magnetic bone-conduction system.
    Signal transmissionThe external sound processor transmits acoustics through the skin by magnetic coupling to internally implanted components.
    AbutmentThe system has no percutaneous abutment physically connecting the external and internal components.
    Pure-Tone Average (PTA)
    DefinitionPure-tone average (PTA) is hearing sensitivity calculated by averaging thresholds at multiple frequencies.
    MeasurementThe averaged values represent the minimum volume the patient hears at each frequency.
    Typical frequency rangeThe calculation typically uses frequencies from 0.25 to 8 kHz.