Loading...

    Explore
    • Policy Monitoring
    • Live Policy Feed
    • Billing Codes
    • Healthcare Providers
    • Health Insurance Payers
    • States
    • Service Lines
    • Taxonomy Codes
    Lookup tools
    • Billing Code Lookup
    • CPT Modifier Lookup
    • Provider Taxonomy Code Lookup
    • Healthcare Provider & Facility Lookup
    • Health Insurance Payer Lookup
    • Payer Contact Directory

    Policy & Benchmark Tools

    • Prior Authorization Lookup
    • Coverage Criteria Lookup
    • Timely Filing Lookup
    • Billing Code Reimbursement Rates
    • Payer Comparison Dashboard
    • Facility Comparison Dashboard
    • All tools

    Company

    • About OpenPayer
    • Data Sources
    • Request a Policy / Feedback
    • Trek Health
    OpenPayerby Trek Health
    LinkedInYouTube

    © 2026 Trek Health. All rights reserved.

    OpenPayer is built and maintained by Trek Health.

    v1.0.32
    OpenPayerPolicy UpdatesOtorhinolaryngology (ENT)BCBS Rhode Island Bone-Conduction Coverage | OpenP…
    Ask Trek AI about this page
    CurrentBlue Cross Blue Shield - Rhode IslandPolicy N/A

    Implantable Bone-Conduction and Bone-Anchored Hearing Aids

    Customize your policy alerts

    Sign up for all Blue Cross Blue Shield - Rhode Island policy alerts

    Know when Blue Cross Blue Shield - Rhode Island releases new policies or updates existing guidance.

    Monitor payer policy activity

    Receive email alerts as soon as relevant payer policies are published or updated.

    This policy governs coverage, medical necessity, and coding for fully or partially implantable bone-conduction and bone-anchored hearing aids, including implantation, replacement, removal, repair, and device components for Medicare Advantage Plans and Commercial Products.

    Policy Summary
    PayerBlue Cross Blue Shield - Rhode Island
    PolicyImplantable Bone-Conduction and Bone-Anchored Hearing Aids
    Policy CodePolicy N/A
    Change TypeNo material change
    Effective DateJan 1, 2023
    Last ReviewFeb 21, 2024
    Next Review DateN/A
    Key ActionFor Commercial Products, submit the applicable procedure or device code with an ICD-10 diagnosis code from the listed covered ranges.
    SourceLink
    POLICY UPDATE CHANGES

    No material clinical or coverage changes in this revision.

    CoveredMedicare Advantage coverage

    OpenPayer is powered by Trek Health's payer performance platform. Trek continuously ingests, validates, and normalizes Transparency in Coverage data alongside payer policies and other commercial payer data to create a structured payer intelligence foundation. OpenPayer uses this foundation to deliver personalized search results, dynamically generated policy pages, and tailored policy monitoring based on each user's payers, specialties, billing codes, and areas of interest. The same intelligence powers broader payer performance workflows, including reimbursement benchmarking, contract evaluation, payer negotiations, and financial decision-making.

    2
    Commercial coverage pathways
    5+Minimum patient age
    5Listed ICD-10 ranges
    Not coveredOther uses

    Coverage Criteria

    Medicare Advantage Plans

    Covered for Medicare Advantage Plans.

    Medicare Advantage coverage: Implantable bone-conduction and bone-anchored hearing aids are covered.

    The policy does not specify additional medical criteria for Medicare Advantage coverage in this section.

    Commercial Products: Conductive or mixed hearing loss

    May be considered medically necessary when all applicable requirements are met.

    Conductive or mixed hearing loss pathway

    • Underlying indication

      • Congenital or surgically induced malformations, such as atresia, of the external ear canal or middle ear.
      • Chronic infection: Chronic external otitis or otitis media.
      • Tumor of the external canal and/or tympanic cavity.
      • Dermatitis of the external canal.

    Commercial Products: Single-sided sensorineural deafness

    May be considered medically necessary when all requirements are met.

    Single-sided sensorineural deafness pathway: The patient is 5 years of age or older, has single-sided sensorineural deafness with normal hearing in the other ear, and the device is used as an alternative to an air-conduction contralateral routing of signal (CROS) hearing aid.Age 5 years and older; normal hearing in the contralateral ear

    Commercial Products: Not medically necessary uses

    The following uses are considered not medically necessary.

    Other uses of implantable bone-conduction or bone-anchored hearing aids, including use in patients with bilateral sensorineural hearing loss, are considered not medically necessary.

    Evidence is insufficient to determine the effects of the technology on health outcomes.

    Re-insertion after non-medically necessary insertion: Re-insertion of the device after removal is considered not medically necessary when the original insertion was not medically necessary.

    For Commercial Products, other uses of implantable bone-conduction or bone-anchored hearing aids are considered not medically necessary. This includes use in patients with bilateral sensorineural hearing loss, because the evidence is insufficient to determine the effects of the technology on health outcomes.

    When the original device insertion was not medically necessary, re-insertion after removal is also considered not medically necessary.

    Coding and Diagnosis Requirements

    CPT and HCPCS codes covered with no diagnosis edits for Medicare Advantage and medically necessary for Commercial Products with listed ICD-10 diagnosesmixedCovered
    69710Implantation or replacement of electromagnetic bone-conduction hearing device in temporal bone
    69711Removal or repair of electromagnetic bone conduction hearing device in temporal bone
    69714Implantation, osseointegrated implant, skull with percutaneous attachment to external speech processor
    69716Implantation, osseointegrated implant, skull; with magnetic transcutaneous attachment to external speech processor, within the mastoid and/or resulting in removal of less than 100 sq mm surface area of bone deep to the outer cranial cortex
    69717Replacement (including removal of existing device), osseointegrated implant, skull; with percutaneous attachment to external speech processor
    69719Replacement (including removal of existing device), osseointegrated implant, skull; with magnetic transcutaneous attachment to external speech processor, within the mastoid and/or involving a bony defect less than 100 sq mm surface area of bone deep to the outer cranial cortex
    69729Implantation, osseointegrated implant, skull; with attachment to external speech processor, outside of the mastoid
    69730Replacement osseointegrated implant, skull; with attachment to external speech processor, outside the mastoid
    L8625External recharging system for battery for use with cochlear implant or auditory osseointegrated device, replacement only, each
    L8690Auditory osseointegrated device, includes all internal and external components
    1–10 of 13
    1/2
    ICD-10 covered diagnosis codes for Commercial Products onlyICD-10Covered
    H60.60-H60.93Covered ICD-10 diagnosis code range for Commercial Products
    H61.301-H61.399Covered ICD-10 diagnosis code range for Commercial Products
    H65.20-H65.499Covered ICD-10 diagnosis code range for Commercial Products
    H66.10-H66.3X9Covered ICD-10 diagnosis code range for Commercial Products
    H90.0-H90.8Covered ICD-10 diagnosis code range for Commercial Products
    Q16.0-Q16.9Covered ICD-10 diagnosis code range for Commercial Products
    Codes covered for Medicare Advantage Plans and Commercial ProductsHCPCSCovered
    L8618Transmitter cable for use with cochlear implant device or auditory osseointegrated device, replacement
    L8624Lithium ion battery for use with cochlear implant or auditory osseointegrated device speech processor, ear level, replacement, each
    Minimum patient age
    Minimum age5 years and older
    Conductive or mixed hearing loss pathwayApplies to patients with conductive or mixed hearing loss when the device is used as an alternative to an air-conduction hearing aid.
    Single-sided sensorineural deafness pathwayApplies to patients with single-sided sensorineural deafness and normal hearing in the other ear when the device is used as an alternative to an air-conduction CROS hearing aid.

    Provider and Billing Actions

    Billing Rule

    Submit Required Diagnosis Coding

    For Commercial Products, file the applicable CPT or HCPCS procedure/device code with a covered ICD-10 diagnosis code range. Claims submitted with other diagnosis codes are not medically necessary under this policy.

    • CPT 69710, 69711, 69714, 69716, 69717, 69719, 69729, and 69730
    • HCPCS L8625, L8690, L8691, L8693, and L8694
    • Covered ICD-10-CM ranges: H60.60-H60.93; H61.301-H61.399; H65.20-H65.499; H66.10-H66.3X9; H90.0-H90.8; Q16.0-Q16.9
    • L8618 and L8624 are covered for Medicare Advantage Plans and Commercial Products
    Documentation Required

    Document Member Financial Responsibility

    Technology Background

    Implantable bone-conduction and bone-anchored hearing aids transmit amplified sound through the skull to the cochlea, bypassing impaired transmission through the external or middle ear. The systems may use either a percutaneous abutment, in which a vibrational transducer couples directly to a titanium implant anchored in the temporal bone, or transcutaneous magnetic coupling, in which an external sound processor transmits sound through the skin to internally implanted components without a percutaneous abutment.

    Hearing Loss and Device Definitions

    Contralateral routing of signal (CROS)
    SystemContralateral routing of signal (CROS) is a hearing system for transmitting sound from the affected side to the normal or less affected side.
    Microphone locationA microphone is positioned on the affected side.
    Signal destinationThe microphone transmits the signal to an air-conduction hearing aid on the normal or less affected side.
    Percutaneous bone-anchored hearing aid
    System typeA bone-conduction system with a vibrational transducer coupled directly to the skull.
    Coupling methodThe transducer is coupled through a percutaneous abutment that permanently protrudes through the skin.
    Policy Summary
    PayerBlue Cross Blue Shield - Rhode Island
    PolicyImplantable Bone-Conduction and Bone-Anchored Hearing Aids
    Policy CodePolicy N/A
    Change TypeNo material change
    Effective DateJan 1, 2023
    Last ReviewFeb 21, 2024
    Next Review DateN/A
    Key ActionFor Commercial Products, submit the applicable procedure or device code with an ICD-10 diagnosis code from the listed covered ranges.
    SourceLink
    On This Page
    Coverage CriteriaCoding and Diagnosis RequirementsProvider and Billing ActionsTechnology BackgroundHearing Loss and Device Definitions

    Before providing services that may be the member's financial responsibility, inform the member and obtain written agreement in advance to continue treatment at the member's own expense, as required by the participation agreement.

    • Do not charge the member for services determined to be not medically necessary, or for medically necessary services that are noncovered benefits, unless the required advance written agreement has been obtained.
    Denial Risk

    Noncovered Clinical Uses

    Do not bill implantable bone-conduction or bone-anchored hearing aids for uses outside the specified covered indications. Other uses, including treatment of bilateral sensorineural hearing loss, are not medically necessary because evidence is insufficient; reinsertion after removal is also not medically necessary when the original insertion was not medically necessary.

    • Covered indications include qualifying conductive or mixed hearing loss in patients age 5 or older associated with specified external-ear or middle-ear conditions, or qualifying single-sided sensorineural deafness with normal hearing in the other ear.
    • Noncovered clinical uses may result in denial and member financial responsibility restrictions may apply.
    Denial Risk

    Prevent Diagnosis-Code Mismatch

    The listed CPT and HCPCS procedure/device codes must be filed with an ICD-10 diagnosis code from the specified covered ranges for Commercial Products. A diagnosis outside those ranges creates a diagnosis-code mismatch and is not medically necessary.

    • Accepted ICD-10-CM ranges: H60.60-H60.93; H61.301-H61.399; H65.20-H65.499; H66.10-H66.3X9; H90.0-H90.8; Q16.0-Q16.9
    • Use the diagnosis that supports the applicable covered indication; other diagnosis codes do not satisfy the Commercial Products coding requirement.
    Billing Rule

    Check Plan Benefit Limitations

    Verify the member's benefit design before scheduling or billing. Benefits may vary by group or contract, and the applicable benefit documents control surgery benefits, coverage limitations, and whether services that are not medically necessary are covered.

    • Review the applicable Benefit Booklet, Evidence of Coverage, or Subscriber Agreement.
    • Confirm surgery benefits and limitations for the service and device.
    • Do not assume this policy creates coverage for a service excluded by the member's contract.
    Note

    Member Contract Controls Coverage

    Use the member's subscriber agreement or member certificate and/or employer agreement to determine benefits and eligibility. Those documents supersede this medical policy for member-specific coverage decisions.

    • For member-specific benefits or eligibility questions, contact the provider call center.
    • Confirm coverage under the applicable contract before rendering services.
    Documentation Required

    Obtain Advance Written Agreement

    If services may be noncovered or not medically necessary and the provider intends to charge the member, inform the member before treatment and obtain an advance written agreement for the member to continue at their own expense.

    • Follow the applicable participation agreement provisions.
    • An agreement obtained after treatment does not satisfy the advance written agreement requirement.
    Implant siteThe abutment extends from a small titanium implant anchored in the temporal bone.
    Transcutaneous bone-anchored hearing system
    System typeA partially implantable magnetic bone-conduction system.
    Coupling methodAcoustic transmission occurs through the skin by magnetic coupling between the external sound processor and internally implanted device components.
    AbutmentNo percutaneous abutment is needed to physically connect the external and internal components.
    Conductive hearing loss
    DefinitionHearing loss caused by impaired transmission through the external or middle ear.
    Affected structuresThe impairment involves sound transmission through the external ear canal or middle ear.
    Hearing-loss categoryConductive hearing loss is one of the three hearing-loss categories described in the policy, along with sensorineural and mixed hearing loss.
    Sensorineural hearing loss
    DefinitionHearing loss involving the inner ear or neural hearing pathway.
    Affected structuresThe condition involves the inner ear or the neural pathway responsible for hearing.
    Hearing-loss categorySensorineural hearing loss is one of the three hearing-loss categories described in the policy, along with conductive and mixed hearing loss.
    Mixed hearing loss
    DefinitionHearing loss with both conductive and sensorineural components.
    Conductive componentThe hearing loss includes impaired transmission through the external or middle ear.
    Sensorineural componentThe hearing loss also involves the inner ear or neural hearing pathway.