Loading...

    Explore
    • Policy Monitoring
    • Live Policy Feed
    • Billing Codes
    • Healthcare Providers
    • Health Insurance Payers
    • States
    • Service Lines
    • Taxonomy Codes
    Lookup tools
    • Billing Code Lookup
    • CPT Modifier Lookup
    • Provider Taxonomy Code Lookup
    • Healthcare Provider & Facility Lookup
    • Health Insurance Payer Lookup
    • Payer Contact Directory

    Policy & Benchmark Tools

    • Prior Authorization Lookup
    • Coverage Criteria Lookup
    • Timely Filing Lookup
    • Billing Code Reimbursement Rates
    • Payer Comparison Dashboard
    • Facility Comparison Dashboard
    • All tools

    Company

    • About OpenPayer
    • Data Sources
    • Request a Policy / Feedback
    • Trek Health
    OpenPayerby Trek Health
    LinkedInYouTube

    © 2026 Trek Health. All rights reserved.

    OpenPayer is built and maintained by Trek Health.

    v1.0.32
    OpenPayerPolicy UpdatesLaboratory/PathologyBCBSRI serum tumor markers Coverage Update | OpenP…
    Ask Trek AI about this page
    CurrentBlue Cross Blue Shield - Rhode IslandPolicy N/A

    Serum Tumor Markers for Breast and Gastrointestinal Malignancies

    Customize your policy alerts

    Sign up for all Blue Cross Blue Shield - Rhode Island policy alerts

    Know when Blue Cross Blue Shield - Rhode Island releases new policies or updates existing guidance.

    Monitor payer policy activity

    Receive email alerts as soon as relevant payer policies are published or updated.

    Policy governing coverage of specific serum tumor marker immunoassays (CA 15-3/CA 27.29 and CA 19-9) for management of breast and gastrointestinal cancers for Blue Cross Blue Shield - Rhode Island members.

    Policy Summary
    PayerBlue Cross Blue Shield - Rhode Island
    PolicySerum Tumor Markers for Breast and Gastrointestinal Malignancies
    Policy CodePolicy N/A
    Change TypeNo material changes
    Effective DateMay 1, 2026
    Last ReviewMar 6, 2026
    Next Review DateMar 6, 2026
    Key ActionOrdering physicians must manage authorizations and appeals; laboratories may not obtain authorizations on behalf of the ordering physician.
    SourceLink
    POLICY UPDATE CHANGES

    No material clinical or coverage changes in this revision.

    2specific immunoassay CPT codes mentioned

    OpenPayer is powered by Trek Health's payer performance platform. Trek continuously ingests, validates, and normalizes Transparency in Coverage data alongside payer policies and other commercial payer data to create a structured payer intelligence foundation. OpenPayer uses this foundation to deliver personalized search results, dynamically generated policy pages, and tailored policy monitoring based on each user's payers, specialties, billing codes, and areas of interest. The same intelligence powers broader payer performance workflows, including reimbursement benchmarking, contract evaluation, payer negotiations, and financial decision-making.

    CA 15-3, CA 19-9
    tumor markers addressed
    NCD/LCDMedicare guidance referenced
    05/01/2026policy effective date

    Coverage Criteria

    Covered indications

    Covered when filed with an appropriate diagnosis code or per Medicare NCD/LCD guidance:

    Commercial coverage: Immunoassay tests for CA 15-3 (CA 27.29) and CA 19-9 are covered for commercial products when filed with one of the covered diagnosis codes listed in the Coding section or attachments.

    See Coding section for exact CPT codes and attachments for diagnosis codes.

    Medicare Advantage coverage: Coverage for CA 15-3 (CA 27.29) and CA 19-9 immunoassays is governed by Medicare Advantage Plans National and Local Coverage Determinations; refer to related policies.

    See Related Policies and Medicare NCD/LCD references.

    Benefits may vary between groups and contracts. Refer to the member’s Benefit Booklet or Subscriber Agreement to determine plan-specific coverage, as some provisions—including coverage for certain genetic testing services and expanded biomarker testing—may differ by contract and group.

    This policy notes that some services may be designated as not medically necessary or not covered under a member’s plan. Members and providers should consult the applicable Benefit Booklet or Subscriber Agreement for member-specific determinations and exclusions.

    Covered Indications — Specific Tests

    Management/monitoring of breast and gastrointestinal malignancies

    Management and serial monitoring of established breast and gastrointestinal malignancies when filed with an appropriate covered diagnosis code:

    Required for coverage

    • Breast cancer marker: Testing with CA 15-3 (CA 27.29) immunoassay (CPT 86300) for management or monitoring of breast malignancy when filed with an appropriate covered diagnosis code.

      See Coding section for CPT and diagnosis codes.

    • Gastrointestinal cancer marker: Testing with CA 19-9 immunoassay (CPT 86301) for management or monitoring of gastrointestinal malignancy when filed with an appropriate covered diagnosis code.

      See Coding section for CPT and diagnosis codes.

    Additional notes: Cut-off points for normal versus abnormal marker levels must be established by the performing laboratory; serial monitoring may not require specific cutoffs.

    Coding and Test Identifiers

    Covered CPT Codes (Commercial)CPTCovered
    86300Immunoassay for tumor antigen, quantitative; CA 15-3 (CA 27.29)
    Covered CPT Codes (Medicare reference)CPTCovered
    86301Immunoassay for tumor antigen, quantitative; CA 19-9
    Marker cutoff points — inv-06: Cut-off points and serial monitoring
    RequirementCut-off points must be established for normal versus abnormal marker levels.
    Serial monitoringSerial monitoring of serum tumor markers in established malignancy may not require predefined cutoff points.
    RationaleMost tumor markers are not unique to malignancy; cutoffs distinguish normal/benign elevations from malignant-related elevations.
    Clinical implicationLaboratories should report and use validated reference/cutoff values for single-measurement interpretation; trend interpretation may rely on relative changes over time.

    Frequency Limits

    inv-15: Frequency limits
    Policy statementNo specific frequency limits are provided in this policy for CA 15-3/CA 27.29 or CA 19-9 testing.
    Practice noteFrequency of testing should be determined by clinical need and applicable benefit documents or coverage determinations.
    ReferenceRefer to ordering clinician judgment and any applicable Medicare NCD/LCD guidance for frequency guidance in Medicare Advantage members.

    Provider Actions and Authorization

    Prior Authorization

    Prior authorization responsibility — ordering physician must manage

    Prior authorization is not applicable for these tests; the ordering physician is responsible for managing any authorization or appeal processes. Laboratories are prohibited from obtaining authorization on behalf of the ordering physician or participating in the authorization process.

    • Applies to CPT 86300 and 86301 as noted in Coding.
    • If a laboratory or third party supports any part of the authorization process, BCBSRI may take severe action up to termination from the provider network.
    Documentation Required

    Ordering physician exclusively responsible for authorization actions

    Only the ordering physician may initiate, manage, and document authorizations and appeals; laboratories may not obtain authorizations, participate in the authorization process, or prepare authorization documentation on behalf of the ordering physician.

    Ordering Requirements

    Step Therapy

    ORDERING REQUIREMENTS — ordering physician must manage authorizations and appeals

    Only the ordering physician may manage authorization and appeals; laboratories may not obtain authorizations, participate in the authorization process, or facilitate appeals on behalf of the ordering physician.

    • Using a laboratory representative or anyone with a relationship to a laboratory to obtain authorization or prepare appeal documentation is prohibited and may be deemed a policy violation.

    Not Covered / Contract Exclusions

    Some genetic testing services and expanded biomarker testing may be contract exclusions for certain self-funded groups that have excluded the expanded coverage related to the state mandate (R.I.G.L. §27-1981). For those groups, details about which genetic testing services require prior authorization, are considered not medically necessary, or are excluded are available in the Genetic Testing Services or Proprietary Laboratory Analyses policy and the member’s Benefit Booklet.

    Definitions

    inv-12: CA 15-3 / CA 27.29
    DefinitionCA 15-3 and CA 27.29 are monoclonal antibody–based assays that detect MUC-1 related epitopes used primarily for monitoring breast cancer.
    Comparative sensitivityCA 27.29 has largely replaced CA 15-3 and is reportedly more sensitive than CA 15-3.
    Clinical useThese markers are applied in single measurements or serial monitoring for management of breast malignancy; interpret in clinical context due to non-specific elevations.
    Mechanism noteMUC-1 gene encodes a mucin-like antigen; different antibodies detect different epitopes, accounting for assay differences.
    inv-13: CA 19-9
    DefinitionCA 19-9 is an immunoassay-detected mucinous glycoprotein tumor marker studied in gastrointestinal cancers including pancreatic and colorectal cancer.

    Background

    Serum tumor markers are circulating molecules or substances shed by tumors into the bloodstream that can be detected and quantitated. These markers have been investigated for use in breast and gastrointestinal cancers, with CA 15-3/CA 27.29 (MUC-1 related immunoassays) primarily used for breast cancer monitoring and CA 19-9 studied in gastrointestinal malignancies. Marker levels may be elevated for non-malignant reasons (for example, liver dysfunction), and assays are used either as single measurements or for serial monitoring in established malignancy.

    Policy Summary
    PayerBlue Cross Blue Shield - Rhode Island
    PolicySerum Tumor Markers for Breast and Gastrointestinal Malignancies
    Policy CodePolicy N/A
    Change TypeNo material changes
    Effective DateMay 1, 2026
    Last ReviewMar 6, 2026
    Next Review DateMar 6, 2026
    Key ActionOrdering physicians must manage authorizations and appeals; laboratories may not obtain authorizations on behalf of the ordering physician.
    SourceLink
    On This Page
    Coverage CriteriaCovered Indications — Specific TestsCoding and Test IdentifiersFrequency LimitsProvider Actions and AuthorizationOrdering RequirementsNot Covered / Contract ExclusionsDefinitionsBackground

    Laboratory certification (e.g., CAP, CLIA) is expected; refer to Related Policies for Medicare NCD/LCD guidance.

    • Use of a laboratory representative or third party to obtain authorization or assist with appeals is prohibited.
    • Violation may be deemed a policy violation with severe consequences, including termination from the BCBSRI provider network.
    Documentation Required

    Authorization ownership and documentation — ordering physician only

    Only the ordering physician shall be involved in the authorization, appeal, or other administrative processes related to prior authorization/medical necessity; laboratories are prohibited from obtaining authorizations on behalf of ordering physicians.

    • Laboratories may not act as a representative to obtain authorization, facilitate the authorization process, or prepare documentation for clinical appropriateness.
    • If a laboratory provides a laboratory service that has not been authorized, the service will be denied as the financial liability of the participating laboratory and may not be billed to the member.
    Denial Risk

    Unauthorized laboratory-obtained authorization — financial liability and denial risk

    If a laboratory provides a service that has not been authorized, the service will be denied and the participating laboratory will be financially liable; such services may not be billed to the member.

    • Services provided without proper authorization are denied and may not be billed to the member.
    • Laboratories found to support any portion of obtaining authorization may face severe action, including termination from the BCBSRI provider network.
    Clinical considerationsCA 19-9 levels can be elevated for non-malignant reasons (e.g., impaired hepatic clearance); interpret with caution and clinical correlation.
    Use casesUsed in single measurements or serial monitoring for management of gastrointestinal malignancies; cutoffs should be established for single-measure interpretation.