Loading...

    Explore
    • Policy Monitoring
    • Live Policy Feed
    • Billing Codes
    • Healthcare Providers
    • Health Insurance Payers
    • States
    • Service Lines
    • Taxonomy Codes
    Lookup tools
    • Billing Code Lookup
    • CPT Modifier Lookup
    • Provider Taxonomy Code Lookup
    • Healthcare Provider & Facility Lookup
    • Health Insurance Payer Lookup
    • Payer Contact Directory

    Policy & Benchmark Tools

    • Prior Authorization Lookup
    • Coverage Criteria Lookup
    • Timely Filing Lookup
    • Billing Code Reimbursement Rates
    • Payer Comparison Dashboard
    • Facility Comparison Dashboard
    • All tools

    Company

    • About OpenPayer
    • Data Sources
    • Request a Policy / Feedback
    • Trek Health
    OpenPayerby Trek Health
    LinkedInYouTube

    © 2026 Trek Health. All rights reserved.

    OpenPayer is built and maintained by Trek Health.

    v1.0.32
    OpenPayerPolicy UpdatesHematology/OncologyBlue Cross RI Microwave Coverage | OpenPayer
    Ask Trek AI about this page
    CurrentBlue Cross Blue Shield - Rhode IslandPolicy N/A

    Microwave Tumor Ablation

    Customize your policy alerts

    Sign up for all Blue Cross Blue Shield - Rhode Island policy alerts

    Know when Blue Cross Blue Shield - Rhode Island releases new policies or updates existing guidance.

    Monitor payer policy activity

    Receive email alerts as soon as relevant payer policies are published or updated.

    This policy governs coverage and medical necessity for microwave ablation of primary or metastatic tumors, including authorization and coding requirements. Coverage is primarily limited to unresectable hepatic and lung tumors meeting specified size criteria, with different determinations for BlueCHiP for Medicare and Commercial products.

    Policy Summary
    PayerBlue Cross Blue Shield - Rhode Island
    PolicyMicrowave Tumor Ablation
    Policy CodePolicy N/A
    Change TypeNo material change
    Effective DateFeb 1, 2020
    Last ReviewNov 5, 2019
    Next Review DateN/A
    Key ActionObtain prior authorization before microwave ablation for BlueCHiP for Medicare members; authorization is recommended for Commercial products.
    SourceLink
    POLICY UPDATE CHANGES

    No material clinical or coverage changes in this revision.

    ≤5 cmMaximum single hepatic tumor size
    Up to 3Maximum hepatic nodules
    ≤3 cmMaximum single lung tumor size
    C9751Related HCPCS code

    OpenPayer is powered by Trek Health's payer performance platform. Trek continuously ingests, validates, and normalizes Transparency in Coverage data alongside payer policies and other commercial payer data to create a structured payer intelligence foundation. OpenPayer uses this foundation to deliver personalized search results, dynamically generated policy pages, and tailored policy monitoring based on each user's payers, specialties, billing codes, and areas of interest. The same intelligence powers broader payer performance workflows, including reimbursement benchmarking, contract evaluation, payer negotiations, and financial decision-making.

    2
    Covered anatomic sites

    Coverage Criteria

    Primary or metastatic hepatic tumors

    Microwave ablation of primary or metastatic hepatic tumors may be considered covered when ALL of the following are met:

    Hepatic tumor criteria

    • Unresectability: The tumor is unresectable due to the location of the lesion(s) and/or comorbid conditions.
    • Hepatic tumor burden

      • Single hepatic tumor: A single tumor of ≤5 cm.≤5 cm
      • Multiple hepatic nodules: Up to 3 nodules, with each nodule <3 cm.Up to 3 nodules; each <3 cm

    Primary or metastatic lung tumors

    Microwave ablation of primary or metastatic lung tumors may be considered covered when ALL of the following are met:

    Lung tumor criteria

    • Unresectability: The tumor is unresectable due to the location of the lesion and/or comorbid conditions.
    • Single lung tumor: There is a single tumor of ≤3 cm.≤3 cm

    For BlueCHiP for Medicare, microwave ablation of more than a single primary or metastatic lung tumor is not covered.

    For BlueCHiP for Medicare, microwave ablation of primary or metastatic tumors other than liver or lung is not covered.

    For Commercial products, microwave ablation of more than a single primary or metastatic lung tumor is not medically necessary because the evidence is insufficient to determine the effects of the technology on health outcomes.

    For Commercial products, microwave ablation of primary or metastatic tumors other than liver or lung is not medically necessary because the evidence is insufficient to determine the effects of the technology on health outcomes.

    Coding Requirements

    Related HCPCS CodeHCPCSCovered
    C9751Bronchoscopy, rigid or flexible, transbronchial ablation of lesion(s) by microwave energy, including fluoroscopic guidance, when performed, with computed tomography acquisition(s) and 3-d rendering, computer-assisted, image-guided navigation, and endobronchial ultrasound (ebus) guided transtracheal and/or transbronchial sampling (eg, aspiration[s]/biopsy[ies]) and all mediastinal and/or hilar lymph node stations or structures and therapeutic intervention(s)
    Unlisted CPT ReportingCPT
    No codes listed
    Single hepatic tumor
    Maximum size≤5 cm
    Hepatic nodules
    Maximum numberUp to 3 nodules
    Maximum size per nodule<3 cm each
    Single lung tumor
    Maximum size≤3 cm

    Provider Actions and Authorization

    Prior Authorization

    Prior Authorization Requirements

    Prior authorization is required for BlueCHiP for Medicare members and recommended for Commercial products before microwave tumor ablation.

    • BlueCHiP for Medicare: Prior authorization is required.
    • Commercial products: Prior authorization is recommended.
    Documentation Required

    Document Tumor Characteristics and Unresectability

    Document the tumor site, whether the tumor is primary or metastatic, and the clinical rationale establishing that it is unresectable due to lesion location and/or comorbid conditions. The applicable tumor-size criteria must also be documented.

    • Liver: A single tumor ≤5 cm or up to 3 nodules <3 cm each.
    • Lung: A single tumor ≤3 cm.

    Background

    Microwave ablation uses microwave energy to generate heat, producing thermal coagulation and localized tissue necrosis to destroy tumors and soft tissue. The procedure may be performed through open, laparoscopic, percutaneous, or thoracoscopic approaches, typically with image guidance and sedation or local or general anesthesia.

    Definitions

    Microwave ablation (MWA)
    TechniqueDestroys tumors and soft tissue using microwave energy
    Thermal effectCreates thermal coagulation and localized tissue necrosis
    Microwave coagulation therapy
    Alternate termMicrowave ablation
    Policy Summary
    PayerBlue Cross Blue Shield - Rhode Island
    PolicyMicrowave Tumor Ablation
    Policy CodePolicy N/A
    Change TypeNo material change
    Effective DateFeb 1, 2020
    Last ReviewNov 5, 2019
    Next Review DateN/A
    Key ActionObtain prior authorization before microwave ablation for BlueCHiP for Medicare members; authorization is recommended for Commercial products.
    SourceLink
    On This Page
    Coverage CriteriaCoding RequirementsProvider Actions and AuthorizationBackgroundDefinitions
  1. Document the lesion location and/or comorbid conditions supporting unresectability.
  2. Prior Authorization

    Submit Authorization Before Treatment

    Submit the microwave ablation request through the applicable authorization process before performing the procedure when prior authorization is required or recommended.

    • Obtain authorization before treatment for BlueCHiP for Medicare members.
    • Submit authorization for Commercial products in accordance with the applicable process.

    Unsupported block type: billing_rule

    Denial Risk

    Multiple Lung Tumors

    Microwave ablation of more than a single primary or metastatic lung tumor is subject to product-specific limitations and may not be covered.

    • BlueCHiP for Medicare: Considered not covered.
    • Commercial products: Considered not medically necessary because evidence is insufficient to determine the effects on health outcomes.
    Denial Risk

    Tumors Outside the Liver or Lung

    Microwave ablation of primary or metastatic tumors outside the liver or lung is subject to product-specific limitations and may not be covered.

    • BlueCHiP for Medicare: Considered not covered.
    • Commercial products: Considered not medically necessary because evidence is insufficient to determine the effects on health outcomes.
    Denial Risk

    Failure to Meet Medical Criteria

    Requests that do not meet the applicable unresectability and tumor-size criteria are not eligible for coverage under the medical policy.

    • The tumor must be unresectable due to lesion location and/or comorbid conditions.
    • Liver tumors must meet the single-tumor or nodule-size criteria.
    • Lung tumors must be a single tumor ≤3 cm.
    Billing Rule

    Noncovered or Not Medically Necessary Services

    Services that are not medically necessary or are non-covered may be subject to payment limitations. Member liability is governed by the subscriber agreement, member certificate, employer agreement, and applicable participation agreement.

    • Benefits and eligibility determine whether payment is available; this policy is not a guarantee of payment.
    • Do not bill the member for services determined not medically necessary or non-covered unless the advance written-agreement requirements are satisfied.