Loading...

    Explore
    • Policy Monitoring
    • Live Policy Feed
    • Billing Codes
    • Healthcare Providers
    • Health Insurance Payers
    • States
    • Service Lines
    • Taxonomy Codes
    Lookup tools
    • Billing Code Lookup
    • CPT Modifier Lookup
    • Provider Taxonomy Code Lookup
    • Healthcare Provider & Facility Lookup
    • Health Insurance Payer Lookup
    • Payer Contact Directory

    Policy & Benchmark Tools

    • Prior Authorization Lookup
    • Coverage Criteria Lookup
    • Timely Filing Lookup
    • Billing Code Reimbursement Rates
    • Payer Comparison Dashboard
    • Facility Comparison Dashboard
    • All tools

    Company

    • About OpenPayer
    • Data Sources
    • Request a Policy / Feedback
    • Trek Health
    OpenPayerby Trek Health
    LinkedInYouTube

    © 2026 Trek Health. All rights reserved.

    OpenPayer is built and maintained by Trek Health.

    v1.0.32
    OpenPayerPolicy UpdatesGastroenterologyBCBS Rhode Island Esophageal pH Coverage | OpenPay…
    Ask Trek AI about this page
    CurrentBlue Cross Blue Shield - Rhode IslandPolicy N/A

    Esophageal pH Monitoring

    Customize your policy alerts

    Sign up for all Blue Cross Blue Shield - Rhode Island policy alerts

    Know when Blue Cross Blue Shield - Rhode Island releases new policies or updates existing guidance.

    Monitor payer policy activity

    Receive email alerts as soon as relevant payer policies are published or updated.

    This policy governs coverage of wireless or catheter-based esophageal pH monitoring and catheter-based impedance-pH monitoring for Medicare Advantage and commercial members. It describes when pH monitoring may be medically necessary and identifies impedance-pH monitoring services that are not covered or not medically necessary.

    Policy Summary
    PayerBlue Cross Blue Shield - Rhode Island
    PolicyEsophageal pH Monitoring
    Policy CodePolicy N/A
    Change TypeNo material change
    Effective DateMar 1, 2026
    Last ReviewNov 19, 2025
    Next Review DateN/A
    Key ActionBefore providing non-covered or not medically necessary services at the member's expense, inform the member and obtain written agreement in advance.
    SourceLink
    POLICY UPDATE CHANGES

    No material clinical or coverage changes in this revision.

    2Covered CPT codes
    2Not covered or not medically necessary CPT codes
    96 hoursMaximum wireless monitoring period

    OpenPayer is powered by Trek Health's payer performance platform. Trek continuously ingests, validates, and normalizes Transparency in Coverage data alongside payer policies and other commercial payer data to create a structured payer intelligence foundation. OpenPayer uses this foundation to deliver personalized search results, dynamically generated policy pages, and tailored policy monitoring based on each user's payers, specialties, billing codes, and areas of interest. The same intelligence powers broader payer performance workflows, including reimbursement benchmarking, contract evaluation, payer negotiations, and financial decision-making.

    1 to several daysGeneral monitoring period
    2Product lines addressed
    RequiredAdvance member agreement

    Medical Necessity and Coverage Criteria

    Wireless or Catheter-Based Esophageal pH Monitoring

    Esophageal pH monitoring may be considered medically necessary when the individual is able to report or describe symptoms.

    ONE of the following

    • The individual is an adult able to report symptoms.
    • The individual is a child or adolescent able to report symptoms.

    24-Hour Catheter-Based Monitoring in Infants or Children

    Twenty-four-hour catheter-based esophageal pH monitoring may be considered medically necessary when the individual cannot report or describe symptoms of reflux.

    ALL of the following

    • The individual is an infant or child.
    • The individual is unable to report or describe symptoms of reflux.
    • The monitoring is performed using a 24-hour catheter-based esophageal pH monitoring system.

    Catheter-Based Impedance-pH Monitoring for Refractory GERD

    The use of 24-hour catheter-based impedance-pH monitoring to define refractory GERD is subject to the following coverage determination.

    ALL of the following

    • The individual has established gastroesophageal reflux disease (GERD).
    • The individual is receiving proton pump inhibitor (PPI) therapy.
    • Symptoms have not responded adequately to twice-daily PPI therapy.
    • The test is 24-hour catheter-based impedance-pH monitoring used to define refractory GERD.

    Catheter-based impedance-pH monitoring is not covered for Medicare Advantage Plans and is not medically necessary for Commercial Products when used to define refractory GERD in an individual with established GERD receiving PPI therapy whose symptoms have not responded adequately to twice-daily PPI therapy.

    CPT codes 91034 and 91035 are considered medically necessary for Medicare Advantage Plans and Commercial Products when filed with one of the covered ICD-10-CM diagnosis codes listed for Esophageal pH Monitoring. CPT 91037 and CPT 91038 are not covered for Medicare Advantage Plans.

    The refractory GERD use of 24-hour catheter-based impedance-pH monitoring is not covered for Medicare Advantage Plans and is not medically necessary for Commercial Products. This determination applies when the test is used after inadequate response to twice-daily PPI therapy to define refractory GERD.

    CPT codes 91037 and 91038 are not medically necessary for Commercial Products. CPT 91037 describes esophageal function testing with nasal catheter intraluminal impedance electrode placement, recording, analysis, and interpretation; CPT 91038 describes the same testing when prolonged for greater than 1 hour up to 24 hours.

    Billing and Coding

    Covered CPT CodesCPTCovered
    91034Esophagus, gastroesophageal reflux test; with nasal catheter pH electrode(s) placement, recording, analysis and interpretation
    91035Esophagus, gastroesophageal reflux test; with mucosal attached telemetry pH electrode placement, recording, analysis and interpretation
    Not Covered / Not Medically Necessary CPT CodesCPTNot Covered
    91037Esophageal function test, gastroesophageal reflux test with nasal catheter intraluminal impedance electrode(s) placement, recording, analysis and interpretation
    91038Esophageal function test, gastroesophageal reflux test with nasal catheter intraluminal impedance electrode(s) placement, recording, analysis and interpretation; prolonged (greater than 1 hour, up to 24 hours)
    Covered ICD-10-CM Diagnosis CodesICD-10Covered
    No codes listed
    PPI Therapy Nonresponse
    Clinical contextEstablished gastroesophageal reflux disease (GERD) on proton pump inhibitor (PPI) therapy
    Therapy frequencyTwice-daily PPI therapy
    Nonresponse thresholdSymptoms have not responded adequately to twice-daily PPI therapy
    Wireless pH Monitoring Duration
    Monitoring methodWireless pH monitoring
    Maximum recording periodUp to 96 hours

    Provider and Member Responsibilities

    Documentation Required

    Advance Written Member Agreement Required

    Before charging a member for services determined to be not medically necessary—or, in some cases, medically necessary services that are non-covered benefits—the provider must inform the member and obtain the member’s written agreement in advance to continue treatment at the member’s own expense.

    Denial Risk

    Impedance-pH Monitoring for Refractory GERD

    Twenty-four-hour catheter-based impedance-pH monitoring to define refractory GERD in individuals with established GERD whose symptoms have not responded adequately to twice-daily PPI therapy is not covered for Medicare Advantage Plans and is not medically necessary for Commercial Products.

    Clinical Background

    GERD is commonly diagnosed clinically and treated empirically. Endoscopy may be indicated when symptoms do not respond appropriately to medication or when recurrent chronic symptoms are present. Esophageal pH monitoring may aid diagnosis when endoscopy is nondiagnostic or does not agree with the clinical evaluation.

    Policy Summary
    PayerBlue Cross Blue Shield - Rhode Island
    PolicyEsophageal pH Monitoring
    Policy CodePolicy N/A
    Change TypeNo material change
    Effective DateMar 1, 2026
    Last ReviewNov 19, 2025
    Next Review DateN/A
    Key ActionBefore providing non-covered or not medically necessary services at the member's expense, inform the member and obtain written agreement in advance.
    SourceLink
    On This Page
    Medical Necessity and Coverage CriteriaBilling and CodingProvider and Member ResponsibilitiesClinical Background
    Data transmission
    Radiofrequency telemetry to a receiver worn on the patient's belt
    Billing Rule

    Noncovered Impedance-pH CPT Codes

    Claims for impedance-pH monitoring billed under CPT 91037 or 91038 are not covered for Medicare Advantage Plans and are not medically necessary for Commercial Products.

    • 91037 — Esophageal function test with nasal catheter intraluminal impedance electrode(s), including placement, recording, analysis, and interpretation.
    • 91038 — Esophageal function test with nasal catheter intraluminal impedance electrode(s), including placement, recording, analysis, and interpretation; prolonged (greater than 1 hour, up to 24 hours).
    Denial Risk

    Financial Responsibility and Reimbursement

    Services that are not medically necessary, and in some cases medically necessary services that are non-covered benefits, may not be reimbursed to the provider unless the member was informed in advance and provided the required written agreement to assume financial responsibility. Refer to the applicable participation agreement(s).