Loading...

    Explore
    • Policy Monitoring
    • Live Policy Feed
    • Billing Codes
    • Healthcare Providers
    • Health Insurance Payers
    • States
    • Service Lines
    • Taxonomy Codes
    Lookup tools
    • Billing Code Lookup
    • CPT Modifier Lookup
    • Provider Taxonomy Code Lookup
    • Healthcare Provider & Facility Lookup
    • Health Insurance Payer Lookup
    • Payer Contact Directory

    Policy & Benchmark Tools

    • Prior Authorization Lookup
    • Coverage Criteria Lookup
    • Timely Filing Lookup
    • Billing Code Reimbursement Rates
    • Payer Comparison Dashboard
    • Facility Comparison Dashboard
    • All tools

    Company

    • About OpenPayer
    • Data Sources
    • Request a Policy / Feedback
    • Trek Health
    OpenPayerby Trek Health
    LinkedInYouTube

    © 2026 Trek Health. All rights reserved.

    OpenPayer is built and maintained by Trek Health.

    v1.0.31
    OpenPayerPolicy UpdatesClinical/Medical PolicyBCBS North Dakota Myoelectric Policy | OpenPayer
    Ask Trek AI about this page

    OpenPayer is powered by Trek Health's payer performance platform. Trek continuously ingests, validates, and normalizes Transparency in Coverage data alongside payer policies and other commercial payer data to create a structured payer intelligence foundation. OpenPayer uses this foundation to deliver personalized search results, dynamically generated policy pages, and tailored policy monitoring based on each user's payers, specialties, billing codes, and areas of interest. The same intelligence powers broader payer performance workflows, including reimbursement benchmarking, contract evaluation, payer negotiations, and financial decision-making.

    CurrentBlue Cross Blue Shield - North DakotaPolicy 80

    Myoelectric and Microprocessor Prosthetic and Orthotic Components for the Upper Limb

    Customize your policy alerts

    Sign up for Blue Cross Blue Shield - North Dakota Policy 80 alerts

    Get alerted when Policy 80 changes without checking for updates manually.

    Monitor payer policy activity

    Receive email alerts as soon as relevant payer policies are published or updated.

    Coverage determinations for myoelectric upper-limb prostheses, replacement components, sensor-and-myoelectric systems, and myoelectric or microprocessor-controlled upper-limb orthoses.

    Policy Summary
    PayerBlue Cross Blue Shield - North Dakota
    PolicyMyoelectric and Microprocessor Prosthetic and Orthotic Components for the Upper Limb
    Policy CodePolicy N/A
    Change TypeNo material change
    Effective DateOctober 1, 2026
    Last ReviewAug 1, 2026
    Next Review DateJune 1, 2027
    Key ActionSubmit documentation of the amputation or missing limb, functional need, residual muscle signal testing, and qualified-professional evaluation.
    SourceLink
    POLICY UPDATE CHANGES

    No material clinical or coverage changes in this revision.

    6Initial coverage criteria
    2Replacement pathways
    2Investigational categories
    Wrist or aboveMinimum amputation level

    Coverage Criteria

    Initial myoelectric upper-limb prosthesis

    Myoelectric upper-limb prostheses may be medically necessary when all of the following criteria are met:

    Initial myoelectric upper-limb prosthesis criteria

    • Required criteria A through E

      • Anatomic eligibility: The individual has an amputation or missing limb at the wrist or above, including the forearm or elbow.
      • Functional need: Standard body-powered prosthetic devices cannot be used or are insufficient to meet the individual's functional needs.
      • Residual muscle signal: The remaining arm musculature contains the minimum microvolt threshold required to operate a myoelectric prosthetic device, demonstrated by functional testing using a physical or computer model prosthesis.
    Policy Summary
    PayerBlue Cross Blue Shield - North Dakota
    PolicyMyoelectric and Microprocessor Prosthetic and Orthotic Components for the Upper Limb
    Policy CodePolicy N/A
    Change TypeNo material change
    Effective DateOctober 1, 2026
    Last ReviewAug 1, 2026
    Next Review DateJune 1, 2027
    Key ActionSubmit documentation of the amputation or missing limb, functional need, residual muscle signal testing, and qualified-professional evaluation.
    SourceLink
    On This Page
    Coverage CriteriaCoding and HCPCS CodesProvider Documentation and Denial RisksClinical BackgroundDevice Definitions
    Minimum microvolt threshold
  1. Neurologic and cognitive function: The individual has sufficient neurologic and cognitive function to operate the prosthesis effectively.
  2. Comorbidities: The individual is free of comorbidities that could interfere with function of the prosthesis, such as neuromuscular disease.
  3. Qualified professional functional evaluation

    • Evaluation and training: A qualified professional, such as a prosthetist, determines that, with training, use of a myoelectric prosthesis and associated components is necessary to meet the individual's functional needs.

      The evaluation should consider control, durability and maintenance, function including speed and work capability, usability, and components such as automatic grasp or microprocessor control features.

    • Purpose and use

      • The device is necessary for the individual's functional needs.
      • The device is not primarily for the purpose of allowing the individual to perform leisure or recreational activities.
  4. Replacement of existing myoelectric prosthesis

    Replacement of all or part of an existing myoelectric upper-limb prosthesis may be medically necessary when at least one of the following pathways is met:

    Replacement eligibility

    • Unrepairable malfunction

      • The existing myoelectric upper-limb prosthesis is malfunctioning.
      • The prosthesis cannot be repaired.
      • The prosthesis is no longer under warranty.
    • Significant physiological change: The current prosthesis can no longer meet the individual's functional needs because of a significant change in the individual's physiological condition.

    Replacement not medically necessary

    The following replacement requests are not medically necessary:

    Replacement exclusion: Replacement of all or part of an existing myoelectric upper-limb prosthesis is not medically necessary when the replacement criteria are not met.

    This includes replacement of an existing functioning prosthesis when the policy criteria are not met.

    Other myoelectric components

    Myoelectric upper-limb prosthetic components are not medically necessary under all other conditions:

    Other conditions: Myoelectric upper-limb prosthetic components are considered not medically necessary when the stated medical-necessity criteria do not apply or are not satisfied.

    Investigational technologies

    The following upper-limb technologies are investigational:

    Investigational upper-limb technologies

    • Sensor-and-myoelectric prosthetic components: Upper-limb prosthetic components with both sensor and myoelectric control are investigational.
    • Myoelectric or microprocessor-controlled orthoses: Myoelectric or microprocessor-controlled upper-limb orthoses are investigational.

    Medically Necessary: Initial myoelectric upper-limb prosthesis

    Covered when the applicable policy criteria are met:

    Initial myoelectric upper-limb prosthesis

    • The individual has an amputation or missing limb at the wrist or above.
    • The applicable medical policy criteria are met.

    Medically Necessary: Replacement

    Replacement of all or part of a myoelectric upper-limb prosthesis may be medically necessary when the replacement criteria are met:

    Replacement of myoelectric upper-limb prosthesis or component

    • The existing device is outside its warranty period.
    • The existing device cannot be repaired adequately to meet the individual's functional needs.

    Investigational: Sensor-controlled prosthetic components and powered upper-limb orthoses

    The following technologies are considered investigational because sufficient evidence of improved health outcomes is lacking:

    Investigational technologies

    • Sensor-controlled prosthetic components: Upper-limb prosthetic components with both sensor and myoelectric control are investigational.
    • Powered upper-limb orthoses: Myoelectric or microprocessor-controlled upper-limb orthoses are investigational for any indication, including upper-limb weakness or paresis.

    A myoelectric upper-limb prosthesis requested primarily for leisure or recreational activities does not meet the policy’s functional-purpose requirement. The device must be necessary to address the individual’s functional needs.

    Replacement of an existing functioning myoelectric upper-limb prosthesis is not medically necessary when the policy’s replacement criteria are not met.

    Myoelectric or microprocessor-controlled upper-limb orthoses are considered investigational for any indication, including upper-limb weakness or paresis, because sufficient research has not shown improved health outcomes.

    Replacement of all or part of an existing myoelectric upper-limb prosthesis is not medically necessary when the applicable replacement criteria are not met.

    Myoelectric upper-limb prosthetic components are not medically necessary under all other conditions when the stated medical-necessity criteria do not apply or are not satisfied.

    Replacement of all or part of a myoelectric upper-limb prosthesis is not medically necessary during the device warranty period or when the device can be repaired or adapted adequately to meet the individual’s functional needs.

    Myoelectric upper-limb prostheses are not medically necessary when policy criteria are not met, including replacement of an existing functioning prosthesis or other conditions outside the stated coverage criteria.

    Coding and HCPCS Codes

    Codes listed in policyHCPCS
    A8005Powered, cable driven grip assist glove, hand, finger, includes microprocessor, pressure sensors, all components and accessories, custom fitted Powered, cable driven grip assist glove, hand, finger, includes pressure sensors, glove replacement only
    E1399Durable medical equipment, miscellaneous
    L6026Transcarpal/metacarpal or partial hand disarticulation prosthesis, external power, self-suspended, inner socket with removable forearm section, electrodes
    L6026Transcarpal/metacarpal or partial hand disarticulation prosthesis, external power, self-suspended, inner socket with removable forearm section, electrodes and cables, two batteries, charger, myoelectric control of terminal device, excludes terminal device(s)
    L6693Upper extremity addition, locking elbow, forearm counterbalance
    L6700Upper extremity addition, external powered feature, myoelectronic control
    L6700Upper extremity addition, external powered feature, myoelectronic control module, additional EMG inputs, pattern-recognition decoding intent movement
    L6715Terminal device, multiple articulating digit, includes motor(s), initial issue or replacement
    CodesHCPCS
    E1399Durable medical equipment, miscellaneous.
    L6026Transcarpal/metacarpal or partial hand disarticulation prosthesis, external power, self-suspended, inner socket with removable forearm section, electrodes and cables, two batteries, charger, myoelectric control of terminal device; excludes terminal device(s).
    L6693Upper extremity addition, locking elbow, forearm counterbalance.
    L6700Upper extremity addition, external powered feature, myoelectronic control.
    L6715Upper extremity addition, external powered feature, myoelectronic control module, additional EMG inputs, pattern-recognition decoding intent movement.
    L6880Terminal device, multiple articulating digit, includes motor(s), initial issue or replacement.
    L6881Electric hand, switch or myoelectric controlled, independently articulating digits.
    L6882Electric hand, switch or myoelectric controlled, independently articulating digits, any grasp pattern or combination of grasp patterns, includes motor(s).
    L6925Wrist disarticulation, external power, self-suspended inner socket, removable forearm shell, electrodes, cables, two batteries and one charger, myoelectronic control of terminal device.
    L6935Below elbow, external power, self-suspended inner socket, removable forearm shell, electrodes, cables, two batteries and one charger, myoelectronic control of terminal device.
    1–10 of 15
    1/2
    Myoelectronic control of terminal device and externally powered upper-limb prosthetic componentsHCPCS
    L6882Myoelectronic control of terminal device; the document associates this code with charger and related externally powered upper-limb prosthetic components.
    L6925Myoelectronic control of terminal device; the document associates this code with externally powered upper-limb prosthetic components.
    L6935Below elbow, external power, self-suspended inner socket, removable forearm shell, Otto Bock or equal electrodes, cables, two batteries and one charger, myoelectronic control of terminal device.
    L6945Elbow disarticulation, external power, molded inner socket, removable humeral shell, outside locking hinges, forearm, Otto Bock or equal electrodes, cables, two batteries and one charger, myoelectronic control of terminal device.
    L6955Above elbow, external power, molded inner socket, removable humeral shell, internal locking elbow, forearm, Otto Bock or equal electrodes, cables, two batteries and one charger, myoelectronic control of terminal device.
    L6965Shoulder disarticulation, external power, molded inner socket, removable shoulder shell, shoulder bulkhead, humeral section, mechanical elbow, forearm, Otto Bock or equal electrodes, cables, two batteries and one charger, myoelectronic control of terminal device.
    L6975Interscapular-thoracic, external power, molded inner socket, removable shoulder shell, shoulder bulkhead, humeral section, mechanical elbow, forearm, Otto Bock or equal electrodes, cables, two batteries and one charger, myoelectronic control of terminal device.
    Electric handsHCPCS
    L7007Electric hand, switch or myoelectric controlled, adult.
    L7008Electric hand, switch or myoelectric controlled, pediatric.
    Upper-limb myoelectric, externally powered, and microprocessor prosthetic componentsHCPCS
    L6935
    L6945
    L6955Above elbow, external power, molded inner socket, removable humeral shell, internal locking elbow, forearm, Otto Bock or equal electrodes, cables, two batteries and one charger, myoelectronic control of terminal device
    L6965Shoulder disarticulation, external power, molded inner socket, removable shoulder shell, shoulder bulkhead, humeral section, mechanical elbow, forearm, Otto Bock or equal electrodes, cables, two batteries and one charger, myoelectronic control of terminal device
    L6975Interscapular-thoracic, external power, molded inner socket, removable shoulder shell, shoulder bulkhead, humeral section, mechanical elbow, forearm, Otto Bock or equal electrodes, cables, two batteries and one charger, myoelectronic control of terminal device
    L7007Electric hand, switch or myoelectric controlled, adult
    L7008Electric hand, switch or myoelectric controlled, pediatric
    L7009Electric hook, switch or myoelectric controlled, adult
    L7045Electric hook, switch or myoelectric controlled, pediatric
    L7180Electronic elbow, microprocessor sequential control of elbow and terminal device
    1–10 of 11
    1/2
    HCPCS upper-limb prosthetic component codesHCPCS
    L6955
    L6965
    L6975Interscapular-thoracic, external power, molded inner socket, removable shoulder shell, shoulder bulkhead, humeral section, mechanical elbow, forearm, Otto Bock or equal electrodes, cables, two batteries and one charger, myoelectronic control of terminal device
    L7007Electric hand, switch or myoelectric controlled, adult
    L7008Electric hand, switch or myoelectric controlled, pediatric
    L7009Electric hook, switch or myoelectric controlled, adult
    L7045Electric hook, switch or myoelectric controlled, pediatric
    L7180Electronic elbow, microprocessor sequential control of elbow and terminal device
    L7181Electronic elbow, microprocessor simultaneous control of elbow and terminal device
    L7190Electronic elbow, adolescent, Variety Village or equal, myoelectronically controlled
    1–10 of 12
    1/2
    CodesHCPCS
    L6965
    L6975Otto Bock or equal electrodes, cables, two batteries and one charger, myoelectronic control of terminal device
    L7007Electric hand, switch or myoelectric controlled, adult
    L7008Electric hand, switch or myoelectric controlled, pediatric
    L7009Electric hook, switch or myoelectric controlled, adult
    L7045Electric hook, switch or myoelectric controlled, pediatric
    L7180Electronic elbow, microprocessor sequential control of elbow and terminal device
    L7181Electronic elbow, microprocessor simultaneous control of elbow and terminal device
    L7190Electronic elbow, adolescent, Variety Village or equal, myoelectronically controlled
    L7191Electronic elbow, child, Variety Village or equal, myoelectronically controlled
    1–10 of 14
    1/2
    Residual musculature signal
    ThresholdMinimum microvolt threshold sufficient to operate the myoelectric device
    How demonstratedFunctional testing using a physical or computer model prosthesis
    Numeric valueThe policy does not specify a numeric microvolt value

    Provider Documentation and Denial Risks

    Documentation Required

    Anatomic and Functional Need

    Submit history and physical examination or chart notes documenting the anatomic and functional need for the requested myoelectric upper-limb prosthesis.

    • Document amputation or missing limb at the wrist or above, including the level (for example, forearm or elbow).
    • Document why standard body-powered devices cannot be used or are insufficient, including activities of daily living (ADLs), work functions, or physical activities that cannot currently be performed.
    Documentation Required

    Residual Muscle Signal Testing

    Document that the remaining musculature contains the minimum microvolt threshold needed to operate the myoelectric prosthesis.

    • Include functional testing using a physical or computer model prosthesis.
    Documentation Required

    Cognitive, Neurologic, and Comorbidity Assessment

    Document sufficient cognitive and neurologic function to operate the prosthesis effectively and confirm that comorbidities will not interfere with prosthesis use.

    • Address cognitive and neurologic ability to operate the prosthesis.
    • Document the absence of comorbidities that could interfere with function, such as neuromuscular disease.
    Documentation Required

    Qualified Professional Evaluation

    Obtain an evaluation by a qualified professional, such as a prosthetist, addressing whether the individual can control, maintain, and functionally use the device with training.

    • Explain why the prosthesis is necessary for ADLs, job functions, or physical activities.
    • Address control, durability and maintenance, function including speed and work capability, usability, and relevant features such as automatic grasp or microprocessor control.
    • Confirm the device is necessary for functional needs and is not primarily intended for leisure or recreational activities.
    Documentation Required

    Replacement Documentation

    For replacement of all or part of an existing myoelectric upper-limb prosthesis, submit documentation establishing that the replacement criteria are met and that a functioning prosthesis is not being replaced.

    • Document that the existing prosthesis is malfunctioning, cannot be repaired, and is no longer under warranty; or that a significant physiological change prevents the current prosthesis from meeting functional needs.
    • Include supporting evidence for the reported malfunction, failed repair or adaptation, warranty status, or significant change in physiological condition.
    • Document that the requested prosthesis is not replacing a functioning prosthesis.
    Denial Risk

    Failure to Meet Initial Coverage Criteria

    Initial coverage may be denied when any required medical-necessity criterion is not met or is not supported by submitted documentation.

    • The individual must have an amputation or missing limb at the wrist or above.
    • Standard body-powered devices must be unusable or insufficient for the individual's functional needs.
    • Required muscle signal, cognitive and neurologic ability, absence of limiting comorbidities, and qualified professional functional evaluation must be documented.
    • The device must be necessary for functional needs and not primarily for leisure or recreational activities.
    Denial Risk

    Replacement Conditions Not Established

    Replacement is not medically necessary when the existing myoelectric prosthesis can be repaired or adapted adequately, remains under warranty, or continues to meet the individual's functional needs.

    • Replacement criteria require a malfunctioning device that cannot be repaired and is no longer under warranty, or a significant physiological change causing the current device to no longer meet functional needs.
    • Replacement of an existing functioning prosthesis, or replacement when policy criteria are otherwise unmet, is not medically necessary.
    Denial Risk

    Noncovered or Investigational Technology

    Other myoelectric components and investigational technologies are not covered as medically necessary under this policy, and specified technologies are considered investigational.

    • Myoelectric upper-limb prosthetic components are not medically necessary under conditions other than those meeting the policy criteria.
    • Upper-limb prosthetic components with both sensor and myoelectric control are investigational.
    • Myoelectric or microprocessor-controlled upper-limb orthoses are investigational.
    Billing Rule

    Contractual Benefit Limitation

    Medical policies provide guidance, but benefit determinations are based on the applicable member contract. If policy language conflicts with contract language, the contract language takes precedence.

    • Contracts may exclude investigational or cosmetic services and procedures.
    • Providers should inform members before rendering excluded investigational or cosmetic services that they may be financially responsible.
    Denial Risk

    Replacement During Warranty or When Repair Is Adequate

    Do not request replacement of a myoelectric upper-limb prosthesis while it is under warranty or when it can be repaired or adapted adequately to meet the individual's functional needs.

    • Replacement under these circumstances is not medically appropriate and is considered not medically necessary.
    Denial Risk

    Criteria Not Met or Functioning Prosthesis Replacement

    Replacement may be denied when replacement criteria are not met, including when the existing prosthesis is functioning or still meets the individual's functional needs.

    • Initial prosthesis requests may also be denied when policy medical-necessity criteria are not met.
    • Replacement of an existing functioning prosthesis is not medically necessary when policy criteria are unmet.
    Denial Risk

    Investigational Component or Orthosis

    Do not submit sensor-and-myoelectric components or myoelectric or microprocessor-controlled upper-limb orthoses as covered medically necessary technology under this policy.

    • Upper-limb prosthetic components with both sensor and myoelectric control are considered investigational.
    • Myoelectric or microprocessor-controlled upper-limb orthoses are considered investigational, including for upper-limb weakness or paresis.

    Clinical Background

    Upper-limb prostheses are used after amputation or limb loss resulting from trauma, surgery, or congenital anomalies to help restore function and appearance. Myoelectric prostheses detect electrical activity from residual muscles and use it to control battery-powered motors that move the hand, wrist, or elbow. Body-powered prostheses use a harness and cable system, while microprocessor-controlled orthoses use sensor feedback to adjust joint movement in real time.

    Device Definitions

    Myoelectric prosthesis or orthosis
    Power sourcePowered by an external electrical source and battery-powered motors
    Signal processingResidual muscle electrical activity is detected by surface electrodes, amplified, and processed by a controller
    Movement controlProcessed muscle activity drives movement of the hand, wrist, elbow, or other upper-limb joint
    Microprocessor-controlled orthosis
    Device typeAn orthosis that uses feedback from sensors to adjust joint movement
    AdjustmentJoint movement is adjusted in real time on an as-needed basis
    Functional purposeReplaces muscle activity in the affected limb
    Body-powered prosthesis
    Control systemUses a body harness and cable system
    Force transmissionVoluntary movement of the shoulder or limb stump extends the cable and transmits force to the terminal device
    Controlled componentsProvides functional manipulation of the elbow and hand
    Sensor-and-myoelectric prosthesis
    System typeUpper-limb prosthetic system combining EMG electrodes with mechanical sensing and control components
    Additional controlsIncludes switches and movement sensors
    Force sensingIncludes force sensors to enable multiple simultaneous powered movements
    Hybrid system
    ComponentsCombines body-powered and myoelectric components
    Typical useMay be used for high-level amputations at or above the elbow
    Joint controlAllows control of two joints at once through one body-powered and one myoelectric component
    Myoelectric orthosis
    Device typeMyoelectric-powered upper-extremity orthotic device
    Signal detectionDetects weak muscle activity from affected muscle groups
    Adjustable functionsAllows adjustment of assistance gain, signal boost, thresholds, and range of motion
    Microprocessor-controlled orthosis
    Integrated componentsSensors, a microprocessor-based control unit, and actuators
    Sensor inputsContinuously captures joint angles, load, and speed
    Dynamic adjustmentDynamically adjusts joint support and resistance to improve stability and energy efficiency
    Carbonhand
    Device typeAssistive grip-strengthening glove
    Grip detectionUses pressure sensors to detect when the user initiates a grip
    Powered assistanceApplies the power needed to ensure a firm grip and enhance the force applied by the user