Loading...

    Explore
    • Policy Monitoring
    • Live Policy Feed
    • Billing Codes
    • Healthcare Providers
    • Health Insurance Payers
    • States
    • Service Lines
    • Taxonomy Codes
    Lookup tools
    • Billing Code Lookup
    • CPT Modifier Lookup
    • Provider Taxonomy Code Lookup
    • Healthcare Provider & Facility Lookup
    • Health Insurance Payer Lookup
    • Payer Contact Directory

    Policy & Benchmark Tools

    • Prior Authorization Lookup
    • Coverage Criteria Lookup
    • Timely Filing Lookup
    • Billing Code Reimbursement Rates
    • Payer Comparison Dashboard
    • Facility Comparison Dashboard
    • All tools

    Company

    • About OpenPayer
    • Data Sources
    • Request a Policy / Feedback
    • Trek Health
    OpenPayerby Trek Health
    LinkedInYouTube

    © 2026 Trek Health. All rights reserved.

    OpenPayer is built and maintained by Trek Health.

    v1.0.32
    OpenPayerPolicy UpdatesPhysical Medicine, Rehab & TherapiesAmeriHealth Caritas LA E-Stim Coverage | OpenPayer
    Ask Trek AI about this page
    CurrentAmeriHealth Caritas LouisianaPolicy CCP.1377

    Electrical Muscle Stimulation

    Customize your policy alerts

    Sign up for amerihealthcaritaslouisiana Policy CCP.1377 alerts

    Get alerted when Policy CCP.1377 changes without checking for updates manually.

    Monitor payer policy activity

    Receive email alerts as soon as relevant payer policies are published or updated.

    Coverage determinations for electrical muscle stimulation, including neuromuscular and functional electrical stimulation, for specified rehabilitation indications, subject to plan benefits, applicable laws, FDA labeling, and the clinical criteria in this policy.

    Policy Summary
    PayerAmeriHealth Caritas Louisiana
    PolicyElectrical Muscle Stimulation
    Policy CodePolicy CCP.1377
    Change TypeNo material change
    Effective DateN/A
    Last ReviewMay 1, 2024
    Next Review DateSeptember 1, 2025
    Key ActionUse the device according to applicable FDA labeling and verify that all Parastep 1 eligibility criteria are met.
    SourceLink
    POLICY UPDATE CHANGES

    No material clinical or coverage changes in this revision.

    5Covered indication groups
    20–50 HzTypical stimulation frequency

    OpenPayer is powered by Trek Health's payer performance platform. Trek continuously ingests, validates, and normalizes Transparency in Coverage data alongside payer policies and other commercial payer data to create a structured payer intelligence foundation. OpenPayer uses this foundation to deliver personalized search results, dynamically generated policy pages, and tailored policy monitoring based on each user's payers, specialties, billing codes, and areas of interest. The same intelligence powers broader payer performance workflows, including reimbursement benchmarking, contract evaluation, payer negotiations, and financial decision-making.

    0.5–100 Hz
    Transcutaneous frequency
    1–20,000 HzElectroceutical frequency
    6+ monthsParastep post-injury threshold

    Covered and Non-Covered Uses

    Covered indications

    Electrical muscle stimulation may be medically necessary when all applicable requirements are met.

    Covered use requirements

    • Covered indications

      • Central neurologic foot drop: Correction of foot drop of central neurological origin when an ankle-foot orthosis is not tolerated.
      • Immobilization-related atrophy: Attenuation of muscle disuse atrophy in an immobilized lower limb following a non-neurological injury or surgery when nerve supply is intact.
      • Post-stroke glenohumeral subluxation: Correction or prevention of glenohumeral subluxation after an acute or subacute stroke.
      • Upper-limb neurologic rehabilitation: Restoration of upper-limb function after an acute or subacute stroke or spinal cord injury in a person with minimal volitional movement, combined with task-specific training.
      • Parastep 1 independent ambulation

        • Neurologic and functional eligibility: The member has intact lower motor units from L1 downward; stability for weight bearing with balance and trunk control; responsive muscles and sensation to stimulation; independent transfers and standing for three or more minutes; motivation and ability to use the device long term; finger function to operate controls; at least six months post-injury or surgery; and no hip or knee degeneration or osteoporotic fractures.Standing: 3+ minutes; post-injury or surgery: 6+ months

    Not medically necessary uses

    Electrical muscle stimulation is not medically necessary for the following uses because safety and effectiveness have not been established. The list is not exhaustive.

    • Spinal cord injury atrophy: Treatment of muscle disuse atrophy in a member with spinal cord injury.
    • Pain control: Use for pain control.
    • Non-medical exercise: Use for a non-medical purpose, such as exercise.
    • Oropharyngeal dysphagia: Use for oropharyngeal dysphagia.
    • Edema reduction:

    All other uses of electrical muscle stimulation are not medically necessary, including but not limited to muscle disuse atrophy in members with spinal cord injury, pain control, non-medical uses such as exercise, oropharyngeal dysphagia, edema reduction, and knee osteoarthritis in a non-surgical member.

    The listed non-covered uses are considered not medically necessary because the safety and effectiveness have not been established for those applications.

    Product Codes and Technical Parameters

    Neuromuscular electrical stimulator FDA product codesmixed
    IPFFDA product code for neuromuscular electrical stimulators
    GZIFDA product code for neuromuscular electrical stimulators
    MKDFDA product code for neuromuscular electrical stimulators
    Transcutaneous electrical nerve stimulator FDA product codemixed
    LIHFDA product code for transcutaneous electrical nerve stimulators, including devices used for interferential current therapy
    Parastep 1 standing requirement
    Standing requirementIndependent standing for three plus minutes is required.
    Transfer requirementThe member must be able to perform independent transfers.
    Weight-bearing requirementThe member must have stability for weight bearing with balance and trunk control.
    Parastep 1 timing requirement
    Post-injury or surgery requirementThe member must be at least six plus months post-injury or surgery.
    Neurologic requirementLower motor units from L1 downward must be intact.

    Provider Guidance and Denial Risks

    Denial Risk

    Avoid unlisted or excluded uses

    Do not request coverage for electrical muscle stimulation uses outside the policy’s covered indications. These uses are not medically necessary because safety and effectiveness have not been established.

    • Examples include muscle disuse atrophy in members with spinal cord injury, pain control, non-medical uses such as exercise, oropharyngeal dysphagia, edema reduction, and knee osteoarthritis in a non-surgical member.
    Denial Risk

    Follow FDA labeling instructions

    Use the device in accordance with the U.S. Food and Drug Administration labeling instructions applicable to that device. Coverage may be denied when the device is not used according to those instructions.

    Denial Risk

    Verify all Parastep 1 eligibility criteria

    Electrical Muscle Stimulation Overview

    Electrical muscle stimulation, also called neuromuscular electrical stimulation or e-stim, delivers electrical current to produce muscle tetany and contraction. It is primarily used to address muscle atrophy during temporary extremity immobilization or to pair stimulation with a functional task in people with neurologic impairment. Functional electrical stimulation may assist foot-drop correction, standing, walking, upper-extremity function, and prevention or correction of glenohumeral subluxation. Electrodes may be positioned transcutaneously, percutaneously, or subcutaneously, and portable devices may be used in clinical or home settings.

    Modality Definitions

    Electrical muscle stimulation / neuromuscular electrical stimulation
    DefinitionElectrical muscle stimulation, also called neuromuscular electrical stimulation or e-stim, delivers electrical current to produce muscle tetany and contraction.
    Typical frequencyTypically 20–50 Hz.
    Common purposesTreats muscle atrophy during temporary extremity immobilization and may be paired with a functional task in neurologically impaired individuals.
    Functional electrical stimulation
    DefinitionElectrical muscle stimulation paired simultaneously or intermittently with a functional task to assist movement or function in neurologically impaired individuals.
    Lower-extremity applicationsMay assist stationary exercise, standing, and walking.
    Policy Summary
    PayerAmeriHealth Caritas Louisiana
    PolicyElectrical Muscle Stimulation
    Policy CodePolicy CCP.1377
    Change TypeNo material change
    Effective DateN/A
    Last ReviewMay 1, 2024
    Next Review DateSeptember 1, 2025
    Key ActionUse the device according to applicable FDA labeling and verify that all Parastep 1 eligibility criteria are met.
    SourceLink
    On This Page
    Covered and Non-Covered UsesProduct Codes and Technical ParametersProvider Guidance and Denial RisksElectrical Muscle Stimulation OverviewModality Definitions
    Use to reduce edema.
  1. Non-surgical knee osteoarthritis: Use for knee osteoarthritis in a non-surgical member.
  2. Musculoskeletal requirementThe member must have no hip or knee degeneration or osteoporotic fractures.
    Electrical muscle stimulation frequency
    Typical frequency20–50 Hz.
    Primary effectProduces muscle tetany and contraction.
    Typical modalityElectrical muscle stimulation, also referred to as neuromuscular electrical stimulation or e-stim.
    Transcutaneous method frequency
    Frequency range0.5–100 Hz.
    MethodTranscutaneous methods include transcutaneous electrical nerve stimulation and interferential current.
    Typical effectAlters pain signals without discernable muscle contraction.
    Electroceutical therapy frequency
    Frequency range1–20,000 Hz.
    PurposeMimics the human bioelectric system and addresses bioelectrical and biochemical cellular communication.
    AdministrationDue to safety concerns, it may only be prescribed and administered under the supervision of a healthcare provider experienced in this treatment method.

    For Parastep 1 use to enable independent ambulation, confirm and document that the member meets every listed clinical and functional criterion. Failure to satisfy any criterion creates a coverage risk.

    • Intact lower motor units from L1 down
    • Stability for weight bearing with balance and trunk control
    • Responsive muscles and sensation to stimulation
    • Independent transfers and standing three plus minutes
    • Motivation and ability to use the device long term
    • Finger function to operate controls
    • Six plus months post-injury or surgery
    • No hip/knee degeneration or osteoporotic fractures
    Upper-extremity applicationsMay improve hand function and range of motion and correct or prevent glenohumeral subluxation after stroke.
    Transcutaneous electrical nerve stimulation
    DefinitionA transcutaneous modality that uses lower frequencies to alter pain signals without discernable muscle contraction.
    Frequency rangeApproximately 0.5–100 Hz.
    ExamplesTranscutaneous electrical nerve stimulation and interferential current.
    Electroceutical therapy
    DefinitionElectroceutical therapy, also called bioelectric nerve block, uses electrical frequencies to mimic the human bioelectric system.
    Frequency range1–20,000 Hz.
    Clinical oversightIt may only be prescribed and administered under the supervision of a healthcare provider experienced in this treatment method.